These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 29788838)

  • 1. In vitro and in vivo assessment of oxygenator blood volume for the prediction of clot formation in an ECMO circuit (theory and validation).
    Krivitski N; Galyanov G; Cooper D; Said MM; Rivera O; Mikesell GT; Rais-Bahrami K
    Perfusion; 2018 May; 33(1_suppl):51-56. PubMed ID: 29788838
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Technical Indicators to Evaluate the Degree of Large Clot Formation Inside the Membrane Fiber Bundle of an Oxygenator in an In Vitro Setup.
    Kaesler A; Hesselmann F; Zander MO; Schlanstein PC; Wagner G; Bruners P; Schmitz-Rode T; Steinseifer U; Arens J
    Artif Organs; 2019 Feb; 43(2):159-166. PubMed ID: 30084492
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Flow Monitoring of ECMO Circuit for Detecting Oxygenator Obstructions.
    Sarathy S; Turek JW; Chu J; Badheka A; Nino MA; Raghavan ML
    Ann Biomed Eng; 2021 Dec; 49(12):3636-3646. PubMed ID: 34705123
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Detecting Oxygenator Thrombosis in ECMO: A Review of Current Techniques and an Exploration of Future Directions.
    Leerson J; Tulloh A; Lopez FT; Gregory S; Buscher H; Rosengarten G
    Semin Thromb Hemost; 2024 Mar; 50(2):253-270. PubMed ID: 37640048
    [TBL] [Abstract][Full Text] [Related]  

  • 5. New generation extracorporeal membrane oxygenation with MedTech Mag-Lev, a single-use, magnetically levitated, centrifugal blood pump: preclinical evaluation in calves.
    Fujiwara T; Nagaoka E; Watanabe T; Miyagi N; Kitao T; Sakota D; Mamiya T; Shinshi T; Arai H; Takatani S
    Artif Organs; 2013 May; 37(5):447-56. PubMed ID: 23489176
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A description of a prototype miniature extracorporeal membrane oxygenation circuit using current technologies in a sheep model.
    Terry B; Gunst G; Melchior R; Wolfe D; Feocco N; Graham S; Searles B; Darling E
    J Extra Corpor Technol; 2005 Sep; 37(3):315-7. PubMed ID: 16350388
    [TBL] [Abstract][Full Text] [Related]  

  • 7. D-dimers Are a Predictor of Clot Volume Inside Membrane Oxygenators During Extracorporeal Membrane Oxygenation.
    Dornia C; Philipp A; Bauer S; Stroszczynski C; Schreyer AG; Müller T; Koehl GE; Lehle K
    Artif Organs; 2015 Sep; 39(9):782-7. PubMed ID: 25845704
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evidence of altered haemostasis in an ovine model of venovenous extracorporeal membrane oxygenation support.
    Passmore MR; Fung YL; Simonova G; Foley SR; Diab SD; Dunster KR; Spanevello MM; McDonald CI; Tung JP; Pecheniuk NM; Hay K; Shekar K; Fraser JF
    Crit Care; 2017 Jul; 21(1):191. PubMed ID: 28754139
    [TBL] [Abstract][Full Text] [Related]  

  • 9. In vitro evaluation of a new lithium dilution method of measuring cardiac output and shunt fraction in patients undergoing venovenous extracorporeal membrane oxygenation.
    Linton R; Turtle M; Band D; O'Brien T; Jonas M
    Crit Care Med; 1998 Jan; 26(1):174-7. PubMed ID: 9428562
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Alterations in Pre/Post Oxygenator Flows Due to Fibrin Deposition in the CardioHelp System-A Case Report.
    Wahl T; Stokes A; Varner C; Zeybek B; Bardia A
    J Extra Corpor Technol; 2022 Sep; 54(3):239-241. PubMed ID: 36742210
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A potential propensity for failure secondary to clot embolism in neonatal ECMO.
    Khoshbin E; Machin D; Killer H; Peek GJ; Sosnowski AW; Firmin RK
    Perfusion; 2005 May; 20(3):177-81. PubMed ID: 16038390
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A safe procedure for connecting a continuous renal replacement therapy device into an extracorporeal membrane oxygenation circuit.
    Suga N; Matsumura Y; Abe R; Hattori N; Nakada TA; Oda S
    J Artif Organs; 2017 Jun; 20(2):125-131. PubMed ID: 28341867
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surface-heparinized neonatal ECMO circuit--an experimental animal study.
    Frenckner B; Ehrén H; Palmér K; Gouda I; Larm O; Olsson P
    Perfusion; 1992 Jan; 7(1):47-51. PubMed ID: 10147699
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Establishment and evaluation of a rat model of extracorporeal membrane oxygenation (ECMO) thrombosis using a 3D-printed mock-oxygenator.
    Umei N; Lai A; Miller J; Shin S; Roberts K; Ai Qatarneh S; Ichiba S; Sakamoto A; Cook KE
    J Transl Med; 2021 Apr; 19(1):179. PubMed ID: 33910585
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Analysis of thrombotic deposits in extracorporeal membrane oxygenators by multidetector computed tomography.
    Dornia C; Philipp A; Bauer S; Lubnow M; Müller T; Lehle K; Schmid C; Müller-Wille R; Wiggermann P; Stroszczynski C; Schreyer AG
    ASAIO J; 2014; 60(6):652-6. PubMed ID: 25158889
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Influence of central hemodynamics on VV ECMO oxygen delivery in neonatal animal model.
    Said MM; Rivera O; Mikesell GT; Rais-Bahrami K
    J Neonatal Perinatal Med; 2017; 10(2):139-145. PubMed ID: 28409759
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new phosphorylcholine-coated polymethylpentene oxygenator for extracorporeal membrane oxygenation: a preliminary experience.
    Pieri M; Turla OG; Calabrò MG; Ruggeri L; Agracheva N; Zangrillo A; Pappalardo F
    Perfusion; 2013 Mar; 28(2):132-7. PubMed ID: 23201818
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dynamic oxygenator blood volume during prolonged extracorporeal life support.
    Hendrix RHJ; Kurniawati ER; Schins SFC; Maessen JG; Weerwind PW
    PLoS One; 2022; 17(2):e0263360. PubMed ID: 35108345
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Contrast-Enhanced Ultrasound in Extracorporeal Support: In Vitro Studies and Initial Experience and Safety Data in the Extreme Premature Fetal Lamb Maintained by the Extrauterine Environment for Neonatal Development.
    Didier RA; Sridharan A; Lawrence K; Coleman BG; Davey MG; Flake AW
    J Ultrasound Med; 2019 Aug; 38(8):1971-1978. PubMed ID: 30560564
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A brief clinical case of monitoring of oxygenator performance and patient-machine interdependency during prolonged veno-venous extracorporeal membrane oxygenation.
    Belliato M; Degani A; Buffa A; Sciutti F; Pagani M; Pellegrini C; Iotti GA
    J Clin Monit Comput; 2017 Oct; 31(5):1027-1033. PubMed ID: 27558734
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.