These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 29790479)

  • 1. Long-term clinical outcomes after bioresorbable and permanent polymer drug-eluting stent implantation: final five-year results of the CENTURY II randomised clinical trial.
    Wijns W; Valdes-Chavarri M; Richardt G; Moreno R; Íñiguez-Romo A; Barbato E; Carrié D; Ando K; Merkely B; Kornowski R; Eltchaninoff H; Stojkovic S; Saito S
    EuroIntervention; 2018 Jun; 14(3):e343-e351. PubMed ID: 29790479
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A randomized, prospective, intercontinental evaluation of a bioresorbable polymer sirolimus-eluting coronary stent system: the CENTURY II (Clinical Evaluation of New Terumo Drug-Eluting Coronary Stent System in the Treatment of Patients with Coronary Artery Disease) trial.
    Saito S; Valdes-Chavarri M; Richardt G; Moreno R; Iniguez Romo A; Barbato E; Carrie D; Ando K; Merkely B; Kornowski R; Eltchaninoff H; James S; Wijns W;
    Eur Heart J; 2014 Aug; 35(30):2021-31. PubMed ID: 24847155
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A randomized comparison of novel bioresorbable polymer sirolimus-eluting stent and durable polymer everolimus-eluting stent in patients with acute coronary syndromes: The CENTURY II high risk ACS substudy.
    Jiménez VA; Iñiguez A; Baz JA; Valdés M; Ortiz A; Vuilliomenet A; Mainar V; Dudek D; Banai S; Tüller D; Bonnet JL; De Miguel A; Bastos G; Wijns W; Saito S
    Cardiovasc Revasc Med; 2016 Sep; 17(6):355-61. PubMed ID: 27156201
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of long-term clinical outcomes in multivessel coronary artery disease patients treated either with bioresoarbable polymer sirolimus-eluting stent or permanent polymer everolimus-eluting stent: 5-year results of the CENTURY II randomized clinical trial.
    Iñiguez A; Chevalier B; Richardt G; Neylon A; Jiménez VA; Kornowski R; Carrie D; Moreno R; Barbato E; Serra-Peñaranda A; Guiducci V; Valdés-Chávarri M; Yajima J; Wijns W; Saito S;
    Catheter Cardiovasc Interv; 2020 Feb; 95(2):175-184. PubMed ID: 31033154
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of sirolimus eluting stent with bioresorbable polymer to everolimus eluting stent with permanent polymer in bifurcation lesions: Results from CENTURY II trial.
    Orvin K; Carrie D; Richardt G; Desmet W; Assali A; Werner G; Ikari Y; Fujii K; Goicolea J; Dangoisse V; Manari A; Saito S; Wijns W; Kornowski R
    Catheter Cardiovasc Interv; 2016 May; 87(6):1092-100. PubMed ID: 26268482
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bioresorbable polymer sirolimus-eluting coronary stent compared with permanent polymer everolimus-eluting coronary stent implantation for treatment of small vessel coronary artery disease: CENTURY II trial.
    Wöhrle J; Markovic S; Rottbauer W; Muramatsu T; Kadota K; Vázquez-González N; Odenstedt J; Serra A; Antoniucci D; Varenne O; Saito S; Wijns W
    EuroIntervention; 2016 Jun; 12(2):e167-74. PubMed ID: 27290676
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents.
    Kandzari DE; Koolen JJ; Doros G; Massaro JJ; Garcia-Garcia HM; Bennett J; Roguin A; Gharib EG; Cutlip DE; Waksman R;
    J Am Coll Cardiol; 2018 Dec; 72(25):3287-3297. PubMed ID: 30257191
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A randomised comparison of a novel abluminal groove-filled biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: clinical and angiographic follow-up of the TARGET I trial.
    Gao RL; Xu B; Lansky AJ; Yang YJ; Ma CS; Han YL; Chen SL; Li H; Zhang RY; Fu GS; Yuan ZY; Jiang H; Huo Y; Li W; Zhang YJ; Leon MB;
    EuroIntervention; 2013 May; 9(1):75-83. PubMed ID: 23685298
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Long Coronary Lesions Treated With Thin Strut Bioresorbable Polymer Drug Eluting Stent: Experience From Multicentre Randomized CENTURY II Study.
    Lesiak M; Araszkiewicz A; Grajek S; Colombo A; Lalmand J; Carstensen S; Namiki A; Tobaru T; Merkely B; Moreno R; Barbato E; Wijns W; Saito S
    J Interv Cardiol; 2016 Feb; 29(1):47-56. PubMed ID: 26864951
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Vascular response to bioresorbable polymer sirolimus-eluting stent vs. permanent polymer everolimus-eluting stent at 9-month follow-up: an optical coherence tomography sub-study from the CENTURY II trial.
    Kuramitsu S; Kazuno Y; Sonoda S; Domei T; Jinnouchi H; Yamaji K; Soga Y; Shirai S; Ando K; Saito S
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):34-40. PubMed ID: 26333375
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Targeted therapy with a localised abluminal groove, low-dose sirolimus-eluting, biodegradable-polymer coronary stent - five-year results of the TARGET All Comers randomised clinical trial.
    Lansky AJ; Xu B; Baumbach A; Kelbæk H; van Royen N; Zheng M; Knaapen P; Slagboom T; Johnson TW; Vlachojannis GJ; Arkenbout KE; Holmvang L; Janssens L; Brugaletta S; Naber CK; Schmitz T; Anderson R; Rittger H; Berti S; Barbato E; Toth GG; Maillard L; Valina CM; Buszman PE; Thiele H; Schächinger V; Wijns W
    EuroIntervention; 2023 Dec; 19(10):e844-e855. PubMed ID: 37860860
    [TBL] [Abstract][Full Text] [Related]  

  • 12. BIOFLOW-IV, a randomised, intercontinental, multicentre study to assess the safety and effectiveness of the Orsiro sirolimus-eluting stent in the treatment of subjects with de novo coronary artery lesions: primary outcome target vessel failure at 12 months.
    Saito S; Toelg R; Witzenbichler B; Haude M; Masotti M; Salmeron R; Witkowski A; Uematsu M; Takahashi A; Waksman R; Slagboom T
    EuroIntervention; 2019 Dec; 15(11):e1006-e1013. PubMed ID: 31235458
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A prospective multicentre randomised all-comers trial to assess the safety and effectiveness of the thin-strut sirolimus-eluting coronary stent SUPRAFLEX: rationale and design of the Thin Strut Sirolimus-eluting Stent in All Comers Population vs Everolimus-eluting Stent (TALENT) trial.
    Modolo R; Chichareon P; Kogame N; Asano T; Chang CC; de Winter RJ; Kaul U; Zaman A; Spitzer E; Takahashi K; Katagiri Y; Soliman OII; van Es GA; Morel MA; Onuma Y; Serruys PW
    EuroIntervention; 2019 Jul; 15(4):e362-e369. PubMed ID: 30066672
    [TBL] [Abstract][Full Text] [Related]  

  • 14. 5-year results of a randomized comparison of XIENCE V everolimus-eluting and TAXUS paclitaxel-eluting stents: final results from the SPIRIT III trial (clinical evaluation of the XIENCE V everolimus eluting coronary stent system in the treatment of patients with de novo native coronary artery lesions).
    Gada H; Kirtane AJ; Newman W; Sanz M; Hermiller JB; Mahaffey KW; Cutlip DE; Sudhir K; Hou L; Koo K; Stone GW
    JACC Cardiovasc Interv; 2013 Dec; 6(12):1263-6. PubMed ID: 24239202
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A sirolimus-eluting bioabsorbable polymer-coated stent (MiStent) versus an everolimus-eluting durable polymer stent (Xience) after percutaneous coronary intervention (DESSOLVE III): a randomised, single-blind, multicentre, non-inferiority, phase 3 trial.
    de Winter RJ; Katagiri Y; Asano T; Milewski KP; Lurz P; Buszman P; Jessurun GAJ; Koch KT; Troquay RPT; Hamer BJB; Ophuis TO; Wöhrle J; Wyderka R; Cayla G; Hofma SH; Levesque S; Żurakowski A; Fischer D; Kośmider M; Goube P; Arkenbout EK; Noutsias M; Ferrari MW; Onuma Y; Wijns W; Serruys PW
    Lancet; 2018 Feb; 391(10119):431-440. PubMed ID: 29203070
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biodegradable Polymer Biolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents in Patients With Coronary Artery Disease: Final 5-Year Report From the COMPARE II Trial (Abluminal Biodegradable Polymer Biolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent).
    Vlachojannis GJ; Smits PC; Hofma SH; Togni M; Vázquez N; Valdés M; Voudris V; Slagboom T; Goy JJ; den Heijer P; van der Ent M
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1215-1221. PubMed ID: 28579236
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biodegradable polymer sirolimus-eluting stents versus durable polymer everolimus-eluting stents for primary percutaneous coronary revascularisation of acute myocardial infarction.
    Pilgrim T; Piccolo R; Heg D; Roffi M; Tüller D; Vuilliomenet A; Muller O; Cook S; Weilenmann D; Kaiser C; Jamshidi P; Khattab AA; Taniwaki M; Rigamonti F; Nietlispach F; Blöchlinger S; Wenaweser P; Jüni P; Windecker S
    EuroIntervention; 2016 Dec; 12(11):e1343-e1354. PubMed ID: 26690319
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Ultrathin, bioresorbable polymer sirolimus-eluting stents versus thin, durable polymer everolimus-eluting stents in patients undergoing coronary revascularisation (BIOFLOW V): a randomised trial.
    Kandzari DE; Mauri L; Koolen JJ; Massaro JM; Doros G; Garcia-Garcia HM; Bennett J; Roguin A; Gharib EG; Cutlip DE; Waksman R;
    Lancet; 2017 Oct; 390(10105):1843-1852. PubMed ID: 28851504
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Outcomes of a novel thin-strut bioresorbable-polymer sirolimus-eluting stent in patients with chronic total occlusions: A multicenter registry.
    Azzalini L; Demir OM; Gasparini GL; Grancini L; La Manna A; Ojeda S; Benincasa S; Bellini B; Poletti E; Maccagni D; Soldi M; Iannetta L; Trabattoni D; Gravina G; Hidalgo F; Giannini F; Pan M; Tamburino C; Bartorelli AL; Reimers B; Godino C; Carlino M; Colombo A
    Int J Cardiol; 2018 May; 258():36-41. PubMed ID: 29426631
    [TBL] [Abstract][Full Text] [Related]  

  • 20. First-in-man randomised comparison of the Angiolite durable fluoroacrylate polymer-based sirolimus-eluting stent versus a durable fluoropolymer-based everolimus-eluting stent in patients with coronary artery disease: the ANGIOLITE trial.
    Moreu J; Moreno-Gómez R; Pérez de Prado A; García Del Blanco B; Trillo R; Pinar E; Molina E; Zueco J; Merchán A; Díaz-Fernández JF; Amat I
    EuroIntervention; 2019 Dec; 15(12):e1081-e1089. PubMed ID: 31310239
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.