  • 1. Comparison of Detection Limits of Fourth- and Fifth-Generation Combination HIV Antigen-Antibody, p24 Antigen, and Viral Load Assays on Diverse HIV Isolates.
    Stone M; Bainbridge J; Sanchez AM; Keating SM; Pappas A; Rountree W; Todd C; Bakkour S; Manak M; Peel SA; Coombs RW; Ramos EM; Shriver MK; Contestable P; Nair SV; Wilson DH; Stengelin M; Murphy G; Hewlett I; Denny TN; Busch MP
    J Clin Microbiol; 2018 Aug; 56(8):. PubMed ID: 29793968
    [TBL] [Abstract][Full Text] [Related]  

  • 2. ARCHITECT® HIV Ag/Ab Combo assay: correlation of HIV-1 p24 antigen sensitivity and RNA viral load using genetically diverse virus isolates.
    Brennan CA; Yamaguchi J; Vallari A; Swanson P; Hackett JR
    J Clin Virol; 2013 Jun; 57(2):169-72. PubMed ID: 23485348
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparative evaluation of three FDA-approved HIV Ag/Ab combination tests using a genetically diverse HIV panel and diagnostic specimens.
    Qiu X; Sokoll L; Yip P; Elliott DJ; Dua R; Mohr P; Wang XY; Spencer M; Swanson P; Dawson GJ; Hackett J
    J Clin Virol; 2017 Jul; 92():62-68. PubMed ID: 28535437
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Performance evaluation of three automated human immunodeficiency virus antigen-antibody combination immunoassays.
    Kwon JA; Yoon SY; Lee CK; Lim CS; Lee KN; Sung HJ; Brennan CA; Devare SG
    J Virol Methods; 2006 Apr; 133(1):20-6. PubMed ID: 16313975
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of the sensitivity and specificity of six HIV combined p24 antigen and antibody assays.
    Ly TD; Laperche S; Brennan C; Vallari A; Ebel A; Hunt J; Martin L; Daghfal D; Schochetman G; Devare S
    J Virol Methods; 2004 Dec; 122(2):185-94. PubMed ID: 15542143
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Performance comparison of the 4th generation Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA on the EVOLIS™ automated system versus Abbott ARCHITECT HIV Ag/Ab Combo, Ortho Anti-HIV 1+2 EIA on Vitros ECi and Siemens HIV-1/O/2 enhanced on Advia Centaur.
    Mitchell EO; Stewart G; Bajzik O; Ferret M; Bentsen C; Shriver MK
    J Clin Virol; 2013 Dec; 58 Suppl 1():e79-84. PubMed ID: 24342482
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Analytical sensitivity of four HIV combined antigen/antibody assays using the p24 WHO standard.
    Miedouge M; Grèze M; Bailly A; Izopet J
    J Clin Virol; 2011 Jan; 50(1):57-60. PubMed ID: 20926337
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the Determine™ fourth generation HIV rapid assay.
    Brauer M; De Villiers JC; Mayaphi SH
    J Virol Methods; 2013 Apr; 189(1):180-3. PubMed ID: 23391823
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Screening tests combined with p24 antigen and anti-HIV antibodies in early detection of HIV-1].
    Laperche S; Maniez-Montreuil M; Couroucé AM
    Transfus Clin Biol; 2000 Jun; 7 Suppl 1():18s-24s. PubMed ID: 10919219
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Multicenter evaluation of a new automated fourth-generation human immunodeficiency virus screening assay with a sensitive antigen detection module and high specificity.
    Weber B; Gürtler L; Thorstensson R; Michl U; Mühlbacher A; Bürgisser P; Villaescusa R; Eiras A; Gabriel C; Stekel H; Tanprasert S; Oota S; Silvestre MJ; Marques C; Ladeira M; Rabenau H; Berger A; Schmitt U; Melchior W
    J Clin Microbiol; 2002 Jun; 40(6):1938-46. PubMed ID: 12037046
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performances of four fourth-generation human immunodeficiency virus-1 screening assays.
    Song EY; Hur M; Roh EY; Park MH; Moon HW; Yun YM
    J Med Virol; 2012 Dec; 84(12):1884-8. PubMed ID: 23080491
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Performance evaluation of the ADVIA Centaur(®) HIV Ag/Ab Combo assay.
    Pumarola T; Freeman J; Saxton E; Dillon P; Bal T; van Helden J
    J Virol Methods; 2010 Dec; 170(1-2):16-20. PubMed ID: 20723562
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Seven human immunodeficiency virus (HIV) antigen-antibody combination assays: evaluation of HIV seroconversion sensitivity and subtype detection.
    Ly TD; Martin L; Daghfal D; Sandridge A; West D; Bristow R; Chalouas L; Qiu X; Lou SC; Hunt JC; Schochetman G; Devare SG
    J Clin Microbiol; 2001 Sep; 39(9):3122-8. PubMed ID: 11526139
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma.
    Bentsen C; McLaughlin L; Mitchell E; Ferrera C; Liska S; Myers R; Peel S; Swenson P; Gadelle S; Shriver MK
    J Clin Virol; 2011 Dec; 52 Suppl 1():S57-61. PubMed ID: 21995929
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative multi-assay evaluation of Determine™ HIV-1/2 Ag/Ab Combo rapid diagnostic tests in acute and chronic HIV infection.
    Wratil PR; Rabenau HF; Eberle J; Stern M; Münchhoff M; Friedrichs I; Stürmer M; Berger A; Kuttner-May S; Münstermann D; Lucht A; Meixenberger K; Bannert N; Keppler OT
    Med Microbiol Immunol; 2020 Apr; 209(2):139-150. PubMed ID: 32036450
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Performances of fourth generation HIV antigen/antibody assays on filter paper for detection of early HIV infections.
    Kania D; Truong TN; Montoya A; Nagot N; Van de Perre P; Tuaillon E
    J Clin Virol; 2015 Jan; 62():92-7. PubMed ID: 25464967
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Shortening of the diagnostic window with a new combined HIV p24 antigen and anti-HIV-1/2/O screening test.
    Brust S; Duttmann H; Feldner J; Gürtler L; Thorstensson R; Simon F
    J Virol Methods; 2000 Nov; 90(2):153-65. PubMed ID: 11064116
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reduction of diagnostic window by new fourth-generation human immunodeficiency virus screening assays.
    Weber B; Fall EH; Berger A; Doerr HW
    J Clin Microbiol; 1998 Aug; 36(8):2235-9. PubMed ID: 9665998
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Evaluation of a rapid and simple fourth-generation HIV screening assay for qualitative detection of HIV p24 antigen and/or antibodies to HIV-1 and HIV-2.
    Beelaert G; Fransen K
    J Virol Methods; 2010 Sep; 168(1-2):218-22. PubMed ID: 20561542
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Diagnosing acute HIV infection at point of care: a retrospective analysis of the sensitivity and specificity of a fourth-generation point-of-care test for detection of HIV core protein p24.
    Fitzgerald N; Cross M; O'Shea S; Fox J
    Sex Transm Infect; 2017 Mar; 93(2):100-101. PubMed ID: 27272704
    [TBL] [Abstract][Full Text] [Related]  