BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

233 related articles for article (PubMed ID: 29794233)

  • 1. MSVAT-SPACE-STIR and SEMAC-STIR for Reduction of Metallic Artifacts in 3T Head and Neck MRI.
    Hilgenfeld T; Prager M; Schwindling FS; Nittka M; Rammelsberg P; Bendszus M; Heiland S; Juerchott A
    AJNR Am J Neuroradiol; 2018 Jul; 39(7):1322-1329. PubMed ID: 29794233
    [TBL] [Abstract][Full Text] [Related]  

  • 2. SEMAC-VAT and MSVAT-SPACE sequence strategies for metal artifact reduction in 1.5T magnetic resonance imaging.
    Ai T; Padua A; Goerner F; Nittka M; Gugala Z; Jadhav S; Trelles M; Johnson RF; Lindsey RW; Li X; Runge VM
    Invest Radiol; 2012 May; 47(5):267-76. PubMed ID: 22266987
    [TBL] [Abstract][Full Text] [Related]  

  • 3. PETRA, MSVAT-SPACE and SEMAC sequences for metal artefact reduction in dental MR imaging.
    Hilgenfeld T; Prager M; Heil A; Schwindling FS; Nittka M; Grodzki D; Rammelsberg P; Bendszus M; Heiland S
    Eur Radiol; 2017 Dec; 27(12):5104-5112. PubMed ID: 28698944
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fat-suppressed MR Imaging of the Spine for Metal Artifact Reduction at 3T: Comparison of STIR and Slice Encoding for Metal Artifact Correction Fat-suppressed T
    Lee YH; Hahn S; Kim E; Suh JS
    Magn Reson Med Sci; 2016 Oct; 15(4):371-378. PubMed ID: 26902679
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Instrument visualization using conventional and compressed sensing SEMAC for interventional MRI at 3T.
    Sonnow L; Gilson WD; Raithel E; Nittka M; Wacker F; Fritz J
    J Magn Reson Imaging; 2018 May; 47(5):1306-1315. PubMed ID: 28940951
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Total knee arthroplasty MRI featuring slice-encoding for metal artifact correction: reduction of artifacts for STIR and proton density-weighted sequences.
    Sutter R; Hodek R; Fucentese SF; Nittka M; Pfirrmann CW
    AJR Am J Roentgenol; 2013 Dec; 201(6):1315-24. PubMed ID: 24261373
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Compressed Sensing SEMAC: 8-fold Accelerated High Resolution Metal Artifact Reduction MRI of Cobalt-Chromium Knee Arthroplasty Implants.
    Fritz J; Ahlawat S; Demehri S; Thawait GK; Raithel E; Gilson WD; Nittka M
    Invest Radiol; 2016 Oct; 51(10):666-76. PubMed ID: 27518214
    [TBL] [Abstract][Full Text] [Related]  

  • 8. New-Generation Low-Field Magnetic Resonance Imaging of Hip Arthroplasty Implants Using Slice Encoding for Metal Artifact Correction: First In Vitro Experience at 0.55 T and Comparison With 1.5 T.
    Khodarahmi I; Brinkmann IM; Lin DJ; Bruno M; Johnson PM; Knoll F; Keerthivasan MB; Chandarana H; Fritz J
    Invest Radiol; 2022 Aug; 57(8):517-526. PubMed ID: 35239614
    [TBL] [Abstract][Full Text] [Related]  

  • 9. View-Angle Tilting and Slice-Encoding Metal Artifact Correction for Artifact Reduction in MRI: Experimental Sequence Optimization for Orthopaedic Tumor Endoprostheses and Clinical Application.
    Jungmann PM; Ganter C; Schaeffeler CJ; Bauer JS; Baum T; Meier R; Nittka M; Pohlig F; Rechl H; von Eisenhart-Rothe R; Rummeny EJ; Woertler K
    PLoS One; 2015; 10(4):e0124922. PubMed ID: 25909472
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of Short-Tau Inversion Recovery With Short-Tau Inversion Recovery-Slice Encoding for Metal Artifact Correction for Spine Imaging at 1.5 T in the Setting of Metallic Implants.
    Yang JY; Hsieh TJ; Chen CK; Lin CH; Chou YC
    J Comput Assist Tomogr; 2023 Sep-Oct 01; 47(5):811-819. PubMed ID: 37707413
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Artifact reduction from metallic dental materials in T1-weighted spin-echo imaging at 3.0 tesla.
    Zho SY; Kim MO; Lee KW; Kim DH
    J Magn Reson Imaging; 2013 Feb; 37(2):471-8. PubMed ID: 22941956
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Advanced metal artifact reduction MRI of metal-on-metal hip resurfacing arthroplasty implants: compressed sensing acceleration enables the time-neutral use of SEMAC.
    Fritz J; Fritz B; Thawait GK; Raithel E; Gilson WD; Nittka M; Mont MA
    Skeletal Radiol; 2016 Oct; 45(10):1345-56. PubMed ID: 27497594
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Evaluation of metal artifacts in clinical MR images of patients with total hip arthroplasty using different metal artifact-reducing sequences.
    Müller GM; Lundin B; von Schewelov T; Müller MF; Ekberg O; Månsson S
    Skeletal Radiol; 2015 Mar; 44(3):353-9. PubMed ID: 25472553
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Feasibility of fat-saturated T2-weighted magnetic resonance imaging with slice encoding for metal artifact correction (SEMAC) at 3T.
    Lee YH; Lim D; Kim E; Kim S; Song HT; Suh JS
    Magn Reson Imaging; 2014 Oct; 32(8):1001-5. PubMed ID: 24925839
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Usefulness of slice encoding for metal artifact correction (SEMAC) for reducing metallic artifacts in 3-T MRI.
    Lee YH; Lim D; Kim E; Kim S; Song HT; Suh JS
    Magn Reson Imaging; 2013 Jun; 31(5):703-6. PubMed ID: 23290476
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging.
    Sutter R; Ulbrich EJ; Jellus V; Nittka M; Pfirrmann CW
    Radiology; 2012 Oct; 265(1):204-14. PubMed ID: 22923720
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Improved Visualization of Juxtaprosthetic Tissue Using Metal Artifact Reduction Magnetic Resonance Imaging: Experimental and Clinical Optimization of Compressed Sensing SEMAC.
    Jungmann PM; Bensler S; Zingg P; Fritz B; Pfirrmann CW; Sutter R
    Invest Radiol; 2019 Jan; 54(1):23-31. PubMed ID: 30351283
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Novel Metal Artifact Reduction Techniques with Use of Slice-Encoding Metal Artifact Correction and View-Angle Tilting MR Imaging for Improved Visualization of Brain Tissue near Intracranial Aneurysm Clips.
    Friedrich B; Wostrack M; Ringel F; Ryang YM; Förschler A; Waldt S; Zimmer C; Nittka M; Preibisch C
    Clin Neuroradiol; 2016 Mar; 26(1):31-7. PubMed ID: 25081235
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sparse-SEMAC: rapid and improved SEMAC metal implant imaging using SPARSE-SENSE acceleration.
    Otazo R; Nittka M; Bruno M; Raithel E; Geppert C; Gyftopoulos S; Recht M; Rybak L
    Magn Reson Med; 2017 Jul; 78(1):79-87. PubMed ID: 27454003
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Metal artefact reduction in MRI at both 1.5 and 3.0 T using slice encoding for metal artefact correction and view angle tilting.
    Reichert M; Ai T; Morelli JN; Nittka M; Attenberger U; Runge VM
    Br J Radiol; 2015 Apr; 88(1048):20140601. PubMed ID: 25613398
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.