These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
320 related articles for article (PubMed ID: 29795018)
1. Piezoelectric Actuator with Frequency Characteristics for a Middle-Ear Implant. Shin DH; Cho JH Sensors (Basel); 2018 May; 18(6):. PubMed ID: 29795018 [TBL] [Abstract][Full Text] [Related]
2. A micropower miniature piezoelectric actuator for implantable middle ear hearing device. Wang Z; Mills R; Luo H; Zheng X; Hou W; Wang L; Brown SI; Cuschieri A IEEE Trans Biomed Eng; 2011 Feb; 58(2):452-8. PubMed ID: 21041151 [TBL] [Abstract][Full Text] [Related]
3. Design Study of a Round Window Piezoelectric Transducer for Active Middle Ear Implants. Shin DH Sensors (Basel); 2021 Jan; 21(3):. PubMed ID: 33572684 [TBL] [Abstract][Full Text] [Related]
4. Round window stimulation with an interface coupler demonstrates proof of concept. Frear DL; Nakajima HH Hear Res; 2022 Aug; 421():108512. PubMed ID: 35606210 [TBL] [Abstract][Full Text] [Related]
5. The effect of static force on round window stimulation with the direct acoustic cochlea stimulator. Maier H; Salcher R; Schwab B; Lenarz T Hear Res; 2013 Jul; 301():115-24. PubMed ID: 23276731 [TBL] [Abstract][Full Text] [Related]
6. Fully implantable hearing aid in the incudostapedial joint gap. Koch M; Eßinger TM; Stoppe T; Lasurashvili N; Bornitz M; Zahnert T Hear Res; 2016 Oct; 340():169-178. PubMed ID: 27041338 [TBL] [Abstract][Full Text] [Related]
7. A tri-coil bellows-type round window transducer with improved frequency characteristics for middle-ear implants. Shin DH; Seong KW; Puria S; Lee KY; Cho JH Hear Res; 2016 Nov; 341():144-154. PubMed ID: 27594098 [TBL] [Abstract][Full Text] [Related]
8. [Comparison of differental intracochlear pressures between round window stimulation and ear canal stimulation]. Wang X Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Dec; 29(6):1109-13. PubMed ID: 23469540 [TBL] [Abstract][Full Text] [Related]
9. Design of a dual-coil type electromagnetic actuator for implantable bone conduction hearing devices. Shin DH; Seong KW; Jung ES; Cho JH; Lee KY Technol Health Care; 2019; 27(S1):445-454. PubMed ID: 31045559 [TBL] [Abstract][Full Text] [Related]
10. Concept and evaluation of an endaurally insertable middle-ear implant. Goll E; Dalhoff E; Gummer AW; Heyd A; Wildenstein D; Arnold H; Schraven SP; Kaltenbacher D; Schächtele J; Schäfer A; Burkhardt C; Tavakoli K; Brenk U; Pojtinger A; Remer U; Wesendahl T; Winter M; Zenner HP Med Eng Phys; 2013 Apr; 35(4):532-6. PubMed ID: 22998896 [TBL] [Abstract][Full Text] [Related]
11. Controlled round-window stimulation in human temporal bones yielding reproducible and functionally relevant stapedial responses. Schraven SP; Hirt B; Gummer AW; Zenner HP; Dalhoff E Hear Res; 2011 Dec; 282(1-2):272-82. PubMed ID: 21798325 [TBL] [Abstract][Full Text] [Related]
12. Numerical Study and Optimization of a Novel Piezoelectric Transducer for a Round-Window Stimulating Type Middle-Ear Implant. Liu H; Wang H; Rao Z; Yang J; Yang S Micromachines (Basel); 2019 Jan; 10(1):. PubMed ID: 30634413 [TBL] [Abstract][Full Text] [Related]
13. Influence of ossicular chain malformation on the performance of round-window stimulation: A finite element approach. Liu H; Zhang H; Yang J; Huang X; Liu W; Xue L Proc Inst Mech Eng H; 2019 May; 233(5):584-594. PubMed ID: 30919729 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of implantable actuators by means of a middle ear simulation model. Bornitz M; Hardtke HJ; Zahnert T Hear Res; 2010 May; 263(1-2):145-51. PubMed ID: 20156543 [TBL] [Abstract][Full Text] [Related]
15. A totally implantable hearing system--design and function characterization in 3D computational model and temporal bones. Gan RZ; Dai C; Wang X; Nakmali D; Wood MW Hear Res; 2010 May; 263(1-2):138-44. PubMed ID: 19772909 [TBL] [Abstract][Full Text] [Related]
16. Influence of the middle ear anatomy on the performance of a membrane sensor in the incudostapedial joint gap. Koch M; Seidler H; Hellmuth A; Bornitz M; Lasurashvili N; Zahnert T Hear Res; 2013 Jul; 301():35-43. PubMed ID: 23246425 [TBL] [Abstract][Full Text] [Related]
17. Feasibility of Round Window Stimulation by a Novel Electromagnetic Microactuator. van Drunen WJ; Mueller M; Glukhovskoy A; Salcher R; Wurz MC; Lenarz T; Maier H Biomed Res Int; 2017; 2017():6369247. PubMed ID: 29214174 [TBL] [Abstract][Full Text] [Related]
18. Stapes vibration produced by the output transducer of an implantable hearing aid. Experimental study. Gyo K; Goode RL; Miller C Arch Otolaryngol Head Neck Surg; 1987 Oct; 113(10):1078-81. PubMed ID: 3620129 [TBL] [Abstract][Full Text] [Related]
19. Sensor-actuator component for a Floating Mass Transducer-based fully implantable hearing aid. Eßinger TM; Koch M; Bornitz M; Lasurashvili N; Neudert M; Zahnert T Hear Res; 2019 Jul; 378():157-165. PubMed ID: 30905594 [TBL] [Abstract][Full Text] [Related]
20. A piezoelectric bone-conduction bending hearing actuator. Adamson RB; Bance M; Brown JA J Acoust Soc Am; 2010 Oct; 128(4):2003-8. PubMed ID: 20968371 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]