These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
122 related articles for article (PubMed ID: 29801635)
1. Assessment of MRI issues at 1.5 T for the Temperature Logger Implant. Mahrouyan O; Tøien Ø; Shellock FG J Therm Biol; 2018 May; 74():249-255. PubMed ID: 29801635 [TBL] [Abstract][Full Text] [Related]
2. Assessment of MRI issues for a new cerebral spinal fluid shunt, gravitational valve (GV). Moghtader D; Crawack HJ; Miethke C; Dörlemann Z; Shellock FG Magn Reson Imaging; 2017 Dec; 44():8-14. PubMed ID: 28735732 [TBL] [Abstract][Full Text] [Related]
3. In vitro assessment of 3-T MRI issues for a bioabsorbable, coronary artery scaffold with metallic markers. Shellock FG; Giangarra CJ Magn Reson Imaging; 2014 Feb; 32(2):163-7. PubMed ID: 24315524 [TBL] [Abstract][Full Text] [Related]
4. A next-generation, flow-diverting implant used to treat brain aneurysms: in vitro evaluation of magnetic field interactions, heating and artifacts at 3-T. Karacozoff AM; Shellock FG; Wakhloo AK Magn Reson Imaging; 2013 Jan; 31(1):145-9. PubMed ID: 22901731 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of MRI issues at 3-Tesla for a transcatheter aortic valve replacement (TAVR) bioprosthesis. Saeedi M; Thomas A; Shellock FG Magn Reson Imaging; 2015 May; 33(4):497-501. PubMed ID: 25620522 [TBL] [Abstract][Full Text] [Related]
6. A new vascular coupling device: assessment of MRI issues at 3-tesla. Titterington B; Puschmann C; Shellock FG Magn Reson Imaging; 2014 Jun; 32(5):585-9. PubMed ID: 24581726 [TBL] [Abstract][Full Text] [Related]
7. Evaluation of MRI Issues for a New Wirelessly Powered, Spinal Cord Stimulation Lead With Receiver. Vasquez LP; Chen J; Shellock FG AJR Am J Roentgenol; 2020 Feb; 214(2):406-412. PubMed ID: 31846373 [No Abstract] [Full Text] [Related]
9. In vitro assessment of a fiducial marker for lung lesions: MRI issues at 3 T. Karacozoff AM; Shellock FG AJR Am J Roentgenol; 2013 Jun; 200(6):1234-7. PubMed ID: 23701058 [TBL] [Abstract][Full Text] [Related]
10. MRI safety and imaging artifacts evaluated for a cannulated screw used for guided growth surgery. Thompson RM; Fowler E; Culo B; Shellock FG Magn Reson Imaging; 2020 Feb; 66():219-225. PubMed ID: 31704394 [TBL] [Abstract][Full Text] [Related]
11. Evaluation of Magnetic Resonance Imaging Safety and Imaging Issues Associated with the Occlusion Balloon Used during Fetoscopic Endoluminal Tracheal Occlusion. Victoria T; Johnson AM; Adzick NS; Hedrick HL; Shellock FG Fetal Diagn Ther; 2018; 44(3):179-183. PubMed ID: 28977797 [TBL] [Abstract][Full Text] [Related]
12. Metallic neurosurgical implants: evaluation of magnetic field interactions, heating, and artifacts at 1.5-Tesla. Shellock FG J Magn Reson Imaging; 2001 Sep; 14(3):295-9. PubMed ID: 11536406 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of MRI issues for a new neurological implant, the Sensor Reservoir. Shellock FG; Knebel J; Prat AD Magn Reson Imaging; 2013 Sep; 31(7):1245-50. PubMed ID: 23602731 [TBL] [Abstract][Full Text] [Related]
14. Assessment of MRI Issues at 3 Tesla for a New Metallic Tissue Marker. Cronenweth CM; Shellock FG Int J Breast Cancer; 2015; 2015():823759. PubMed ID: 26266051 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of MRI issues for an access port with a radiofrequency identification (RFID) tag. Titterington B; Shellock FG Magn Reson Imaging; 2013 Oct; 31(8):1439-44. PubMed ID: 23684963 [TBL] [Abstract][Full Text] [Related]
16. In vitro assessment of MRI issues at 3-Tesla for a breast tissue expander with a remote port. Linnemeyer H; Shellock FG; Ahn CY Magn Reson Imaging; 2014 Apr; 32(3):297-302. PubMed ID: 24418326 [TBL] [Abstract][Full Text] [Related]
17. Ventricular assist device implant (AB 5000) prototype cannula: in vitro assessment of MRI issues at 3-Tesla. Shellock FG; Valencerina S J Cardiovasc Magn Reson; 2008 May; 10(1):23. PubMed ID: 18495028 [TBL] [Abstract][Full Text] [Related]
18. Prosthetic heart valves: evaluation of magnetic field interactions, heating, and artifacts at 1.5 T. Edwards MB; Taylor KM; Shellock FG J Magn Reson Imaging; 2000 Aug; 12(2):363-9. PubMed ID: 10931602 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of magnetic resonance imaging issues for a wirelessly powered lead used for epidural, spinal cord stimulation. Shellock FG; Audet-Griffin AJ Neuromodulation; 2014 Jun; 17(4):334-9; discussion 339. PubMed ID: 24024673 [TBL] [Abstract][Full Text] [Related]
20. Prosthetic heart valves and annuloplasty rings: assessment of magnetic field interactions, heating, and artifacts at 1.5 Tesla. Shellock FG J Cardiovasc Magn Reson; 2001; 3(4):317-24. PubMed ID: 11777223 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]