These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
54 related articles for article (PubMed ID: 2980474)
1. Automatic reregistration for correction of localized misregistration artifacts in digital subtraction angiography of the head and neck. Takahashi M; Shinzato J; Korogi Y; Fukui K; Ueno S; Horiba I; Suzumura N Acta Radiol Suppl; 1986; 369():281-4. PubMed ID: 2980474 [TBL] [Abstract][Full Text] [Related]
2. Automatic Remasking of Digital Subtraction Angiography Images in Pulmonary Angiography. Mizukuchi T; Uemura T; Kondo S; Abe S; Adachi S; Okumura N; Kondo T; Koyama S J Digit Imaging; 2020 Apr; 33(2):531-537. PubMed ID: 31625027 [TBL] [Abstract][Full Text] [Related]
3. Nonlinear geometric warping of the mask image: a new method for reducing misregistration artifacts in digital subtraction angiography. Hayashi N; Sakai T; Kitagawa M; Inagaki R; Sadato N; Ishii Y; Nishimoto Y; Tanaka M; Fukushima T; Komuro H; Ogura H; Kobayashi H; Kubota T Cardiovasc Intervent Radiol; 1998; 21(2):138-41. PubMed ID: 9502681 [TBL] [Abstract][Full Text] [Related]
4. [Affine transformation-based automatic registration for peripheral digital subtraction angiography (DSA)]. Kong G; Dai DQ; Zou LM Zhongguo Yi Liao Qi Xie Za Zhi; 2008 Jul; 32(4):261-4. PubMed ID: 18973035 [TBL] [Abstract][Full Text] [Related]
5. An algorithm for correction of distortion in stereotaxic digital subtraction angiography. Söderman M; Picard C; Ericson K Neuroradiology; 1998 May; 40(5):277-82. PubMed ID: 9638667 [TBL] [Abstract][Full Text] [Related]
6. Deep Learning-based Angiogram Generation Model for Cerebral Angiography without Misregistration Artifacts. Ueda D; Katayama Y; Yamamoto A; Ichinose T; Arima H; Watanabe Y; Walston SL; Tatekawa H; Takita H; Honjo T; Shimazaki A; Kabata D; Ichida T; Goto T; Miki Y Radiology; 2021 Jun; 299(3):675-681. PubMed ID: 33787336 [TBL] [Abstract][Full Text] [Related]
7. Reduction of patient motion artifacts in digital subtraction angiography: evaluation of a fast and fully automatic technique. Meijering EH; Niessen WJ; Bakker J; van Der Molen AJ; de Kort GA; Lo RT; Mali WP; Viergever MA Radiology; 2001 Apr; 219(1):288-93. PubMed ID: 11274572 [TBL] [Abstract][Full Text] [Related]
8. Directions and magnitudes of misregistration of CT attenuation-corrected myocardial perfusion studies: incidence, impact on image quality, and guidance for reregistration. Kennedy JA; Israel O; Frenkel A J Nucl Med; 2009 Sep; 50(9):1471-8. PubMed ID: 19690038 [TBL] [Abstract][Full Text] [Related]
9. [A new method of eliminating motion artifacts in DSA]. Ren M; Wang Q; Yang X; Zhu M Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2010 Oct; 27(5):1120-7. PubMed ID: 21089683 [TBL] [Abstract][Full Text] [Related]
10. Comparison of geometric distortion in digital angiography with and without a correction program. Technical note. Zheng Z; Shearer D; Norén G; Chougule P; Friehs G J Neurosurg; 2000 Dec; 93 Suppl 3():223-7. PubMed ID: 11143253 [TBL] [Abstract][Full Text] [Related]
11. Digital subtraction angiogram registration method with local distortion vectors to decrease motion artifact. Hiroshima K; Funakami R; Hiratsuka K; Nishino J; Odaka T; Ogura H; Fukushima T; Nishimoto Y; Tanaka M; Ito H; Yamamoto K J Biomed Inform; 2001 Jun; 34(3):182-94. PubMed ID: 11723700 [TBL] [Abstract][Full Text] [Related]
12. Evolution of digital angiography systems. Brigida R; Misciasci T; Martarelli F; Gangitano G; Ottaviani P; Rollo M; Marano P Rays; 2003; 28(1):21-8. PubMed ID: 14509177 [TBL] [Abstract][Full Text] [Related]
13. Clinical experience with stereotactic digital subtraction angiography with distortion correction software. Ericson K; Söderman M; Maurincomme E; Lindquist C Stereotact Funct Neurosurg; 1996; 66 Suppl 1():63-70. PubMed ID: 9032846 [TBL] [Abstract][Full Text] [Related]
14. [CT subtraction angiography (CTSA). Results with an automated "elastic" subtraction algorithm]. Luboldt W; Stehling MK; Pearlman JD; Seemann M; Raptopoulos V Radiologe; 1997 Jan; 37(1):89-93. PubMed ID: 9157481 [TBL] [Abstract][Full Text] [Related]
15. [The correction for motion and visualization of subtraction angiographic data from the spiral CT]. Beier J; Richter CS; Fleck E; Felix R Rofo; 1995 Jan; 162(1):58-64. PubMed ID: 7841403 [TBL] [Abstract][Full Text] [Related]
16. Candidate image processing for real-time volumetric CT subtraction angiography. Mori S; Endo M Eur J Radiol; 2007 Feb; 61(2):335-41. PubMed ID: 17097254 [TBL] [Abstract][Full Text] [Related]
17. Reducing misregistration of mask image in hepatic DSA. Katsuda T; Kuroda C; Fujita M Radiol Technol; 1997; 68(6):487-90. PubMed ID: 9253058 [TBL] [Abstract][Full Text] [Related]
18. [Development of a new digital angiography system--improvement of rotational angiography and three dimensional image display]. Kumazaki T Nihon Igaku Hoshasen Gakkai Zasshi; 1991 Sep; 51(9):1068-77. PubMed ID: 1945788 [TBL] [Abstract][Full Text] [Related]
19. Quantitative assessment of motion artifacts and validation of a new motion-correction program for myocardial perfusion SPECT. Matsumoto N; Berman DS; Kavanagh PB; Gerlach J; Hayes SW; Lewin HC; Friedman JD; Germano G J Nucl Med; 2001 May; 42(5):687-94. PubMed ID: 11337561 [TBL] [Abstract][Full Text] [Related]
20. A vessel segmentation method for serialized cerebralvascular DSA images based on spatial feature point set of rotating coordinate system. Liu B; Jiang Q; Liu W; Wang M; Zhang S; Zhang X; Zhang B; Yue Z Comput Methods Programs Biomed; 2018 Jul; 161():55-72. PubMed ID: 29852968 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]