These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Assessing sensor accuracy for non-adjunct use of continuous glucose monitoring. Kovatchev BP; Patek SD; Ortiz EA; Breton MD Diabetes Technol Ther; 2015 Mar; 17(3):177-86. PubMed ID: 25436913 [TBL] [Abstract][Full Text] [Related]
4. Rate of Change of Premeal Glucose Measured by Continuous Glucose Monitoring Predicts Postmeal Glycemic Excursions in Patients With Type 1 Diabetes: Implications for Therapy. Majithia AR; Wiltschko AB; Zheng H; Walford GA; Nathan DM J Diabetes Sci Technol; 2018 Jan; 12(1):76-82. PubMed ID: 28868899 [TBL] [Abstract][Full Text] [Related]
5. Use of flash glucose-sensing technology (FreeStyle Libre) in youth with type 1 diabetes: AWeSoMe study group real-life observational experience. Landau Z; Abiri S; Gruber N; Levy-Shraga Y; Brener A; Lebenthal Y; Barash G; Pinhas-Hamiel O; Rachmiel M Acta Diabetol; 2018 Dec; 55(12):1303-1310. PubMed ID: 30171412 [TBL] [Abstract][Full Text] [Related]
6. Overestimation of Hypoglycemia Diagnosis by FreeStyle Libre Continuous Glucose Monitoring in Long-Term Care Home Residents With Diabetes. Alitta Q; Grino M; Adjemout L; Langar A; Retornaz F; Oliver C J Diabetes Sci Technol; 2018 May; 12(3):727-728. PubMed ID: 29251062 [No Abstract] [Full Text] [Related]
8. Usage of continuous glucose monitoring (CGM) for detecting an unrecognized hypoglycemia and management of glucocorticoid replacement therapy in adult patients with central hypoadrenalism. Watanabe T; Ozawa A; Ishii S; Tomaru T; Shibusawa N; Saito T; Yamada E; Horiguchi K; Nakajima Y; Matsumoto S; Yoshino S; Katano-Toki A; Hashimoto K; Mori M; Okada S; Satoh T; Yamada M Endocr J; 2018 May; 65(5):547-556. PubMed ID: 29618670 [TBL] [Abstract][Full Text] [Related]
9. Seizures as the only clinical manifestation of reactive hypoglycemia: a case report. Monami M; Mannucci E; Breschi A; Marchionni N J Endocrinol Invest; 2005 Nov; 28(10):940-1. PubMed ID: 16419498 [TBL] [Abstract][Full Text] [Related]
11. Extensive Assessment of Blood Glucose Monitoring During Postprandial Period and Its Impact on Closed-Loop Performance. Biagi L; Hirata Bertachi A; Conget I; Quirós C; Giménez M; Ampudia-Blasco FJ; Rossetti P; Bondia J; Vehí J J Diabetes Sci Technol; 2017 Nov; 11(6):1089-1095. PubMed ID: 28633537 [TBL] [Abstract][Full Text] [Related]
12. Effect of Insulin Analogs on Frequency of Non-Severe Hypoglycemia in Patients with Type 1 Diabetes Prone to Severe Hypoglycemia: Much Higher Rates Detected by Continuous Glucose Monitoring than by Self-Monitoring of Blood Glucose-The HypoAna Trial. Agesen RM; Kristensen PL; Beck-Nielsen H; Nørgaard K; Perrild H; Jensen T; Parving HH; Thorsteinsson B; Tarnow L; Pedersen-Bjergaard U Diabetes Technol Ther; 2018 Mar; 20(3):247-256. PubMed ID: 29565719 [TBL] [Abstract][Full Text] [Related]
13. Determining clinical and psychological benefits and barriers with continuous glucose monitoring therapy. Halford J; Harris C Diabetes Technol Ther; 2010 Mar; 12(3):201-5. PubMed ID: 20151770 [TBL] [Abstract][Full Text] [Related]
14. Continuous glucose monitoring for patients with type 1 diabetes and impaired awareness of hypoglycaemia (IN CONTROL): a randomised, open-label, crossover trial. van Beers CA; DeVries JH; Kleijer SJ; Smits MM; Geelhoed-Duijvestijn PH; Kramer MH; Diamant M; Snoek FJ; Serné EH Lancet Diabetes Endocrinol; 2016 Nov; 4(11):893-902. PubMed ID: 27641781 [TBL] [Abstract][Full Text] [Related]
15. Bio-behavioral control, glucose variability, and hypoglycemia-associated autonomic failure in type 1 diabetes (T1DM). Breton MD; Farhy LS; Penberthy JK; Kovatchev BP Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():315-8. PubMed ID: 17945578 [TBL] [Abstract][Full Text] [Related]
16. Continuous glucose monitoring in type 2 diabetes. Harman-Boehm I Diabetes Res Clin Pract; 2008 Dec; 82 Suppl 2():S118-21. PubMed ID: 19027978 [TBL] [Abstract][Full Text] [Related]
17. Continuous Glucose Monitoring in Patients with Type 1 Diabetes and Impaired Awareness of Hypoglycemia: Also Effective in Patients with Psychological Distress? van Beers CAJ; de Wit M; Kleijer SJ; Geelhoed-Duijvestijn PH; DeVries JH; Kramer MHH; Diamant M; Serné EH; Snoek FJ Diabetes Technol Ther; 2017 Oct; 19(10):595-599. PubMed ID: 28836833 [TBL] [Abstract][Full Text] [Related]
18. Automatic Detection and Estimation of Unannounced Meals for Multivariable Artificial Pancreas System. Samadi S; Rashid M; Turksoy K; Feng J; Hajizadeh I; Hobbs N; Lazaro C; Sevil M; Littlejohn E; Cinar A Diabetes Technol Ther; 2018 Mar; 20(3):235-246. PubMed ID: 29406789 [TBL] [Abstract][Full Text] [Related]