BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 29846180)

  • 1. Physics considerations in MV-CBCT multi-layer imager design.
    Hu YH; Fueglistaller R; Myronakis M; Rottmann J; Wang A; Shedlock D; Morf D; Baturin P; Huber P; Star-Lack J; Berbeco R
    Phys Med Biol; 2018 Jun; 63(12):125016. PubMed ID: 29846180
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Characterizing a novel scintillating glass for application to megavoltage cone-beam computed tomography.
    Hu YH; Shedlock D; Wang A; Rottmann J; Baturin P; Myronakis M; Huber P; Fueglistaller R; Shi M; Morf D; Star-Lack J; Berbeco RI
    Med Phys; 2019 Mar; 46(3):1323-1330. PubMed ID: 30586163
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A novel method for quantification of beam's-eye-view tumor tracking performance.
    Hu YH; Myronakis M; Rottmann J; Wang A; Morf D; Shedlock D; Baturin P; Star-Lack J; Berbeco R
    Med Phys; 2017 Nov; 44(11):5650-5659. PubMed ID: 28887836
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Leveraging multi-layer imager detector design to improve low-dose performance for megavoltage cone-beam computed tomography.
    Hu YH; Rottmann J; Fueglistaller R; Myronakis M; Wang A; Huber P; Shedlock D; Morf D; Baturin P; Star-Lack J; Berbeco R
    Phys Med Biol; 2018 Jan; 63(3):035022. PubMed ID: 29235440
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A piecewise-focused high DQE detector for MV imaging.
    Star-Lack J; Shedlock D; Swahn D; Humber D; Wang A; Hirsh H; Zentai G; Sawkey D; Kruger I; Sun M; Abel E; Virshup G; Shin M; Fahrig R
    Med Phys; 2015 Sep; 42(9):5084-99. PubMed ID: 26328960
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Low-dose megavoltage cone-beam computed tomography using a novel multi-layer imager (MLI).
    Myronakis M; Huber P; Lehmann M; Fueglistaller R; Jacobson M; Hu YH; Baturin P; Wang A; Shi M; Harris T; Morf D; Berbeco R
    Med Phys; 2020 Apr; 47(4):1827-1835. PubMed ID: 31930516
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A novel multilayer MV imager computational model for component optimization.
    Myronakis M; Star-Lack J; Baturin P; Rottmann J; Morf D; Wang A; Hu YH; Shedlock D; Berbeco RI
    Med Phys; 2017 Aug; 44(8):4213-4222. PubMed ID: 28555935
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Frequency-dependent optimal weighting approach for megavoltage multilayer imagers.
    Valencia Lozano I; Shi M; Myronakis M; Baturin P; Fueglistaller R; Huber P; Lehmann M; Morf D; Ferguson D; Jacobson MW; Harris T; Berbeco RI; Williams CL
    Phys Med Biol; 2021 Apr; 66(8):. PubMed ID: 33503603
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Development of a novel high quantum efficiency MV x-ray detector for image-guided radiotherapy: A feasibility study.
    Liu J; Xu Y; Teymurazyan A; Papandreou Z; Pang G
    Med Phys; 2020 Jan; 47(1):152-163. PubMed ID: 31682020
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Monte Carlo simulation of a novel water-equivalent electronic portal imaging device using plastic scintillating fibers.
    Teymurazyan A; Pang G
    Med Phys; 2012 Mar; 39(3):1518-29. PubMed ID: 22380384
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Modeling and evaluation of a high-resolution CMOS detector for cone-beam CT of the extremities.
    Cao Q; Sisniega A; Brehler M; Stayman JW; Yorkston J; Siewerdsen JH; Zbijewski W
    Med Phys; 2018 Jan; 45(1):114-130. PubMed ID: 29095489
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mobile C-Arm with a CMOS detector: Technical assessment of fluoroscopy and Cone-Beam CT imaging performance.
    Sheth NM; Zbijewski W; Jacobson MW; Abiola G; Kleinszig G; Vogt S; Soellradl S; Bialkowski J; Anderson WS; Weiss CR; Osgood GM; Siewerdsen JH
    Med Phys; 2018 Dec; 45(12):5420-5436. PubMed ID: 30339271
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Full modulation transfer functions of thick parallel- and focused-element scintillator arrays obtained by a Monte Carlo optical transport model.
    Zarrini-Monfared Z; Karbasi S; Zamani A; Mosleh-Shirazi MA
    Med Phys; 2023 Jun; 50(6):3651-3660. PubMed ID: 36779548
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Segmented crystalline scintillators: empirical and theoretical investigation of a high quantum efficiency EPID based on an initial engineering prototype CsI(TI) detector.
    Sawant A; Antonuk LE; El-Mohri Y; Zhao Q; Wang Y; Li Y; Du H; Perna L
    Med Phys; 2006 Apr; 33(4):1053-66. PubMed ID: 16696482
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Monte Carlo simulation of a quantum noise limited Čerenkov detector based on air-spaced light guiding taper for megavoltage x-ray imaging.
    Teymurazyan A; Rowlands JA; Pang G
    Med Phys; 2014 Apr; 41(4):041907. PubMed ID: 24694138
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Theoretical investigation of the design and performance of a dual energy (kV and MV) radiotherapy imager.
    Liu L; Antonuk LE; El-Mohri Y; Zhao Q; Jiang H
    Med Phys; 2015 Apr; 42(4):2072-84. PubMed ID: 25832097
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo investigations of the effect of beam divergence on thick, segmented crystalline scintillators for radiotherapy imaging.
    Wang Y; El-Mohri Y; Antonuk LE; Zhao Q
    Phys Med Biol; 2010 Jul; 55(13):3659-73. PubMed ID: 20526032
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Segmented crystalline scintillators: an initial investigation of high quantum efficiency detectors for megavoltage x-ray imaging.
    Sawant A; Antonuk LE; El-Mohri Y; Zhao Q; Li Y; Su Z; Wang Y; Yamamoto J; Du H; Cunningham I; Klugerman M; Shah K
    Med Phys; 2005 Oct; 32(10):3067-83. PubMed ID: 16279059
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Investigation of image quality of MV and kV CBCT with low-Z beams and high DQE detector.
    O'Connell J; Bazalova-Carter M
    Med Phys; 2022 Apr; 49(4):2334-2341. PubMed ID: 35098549
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Use of a line-pair resolution phantom for comprehensive quality assurance of electronic portal imaging devices based on fundamental imaging metrics.
    Gopal A; Samant SS
    Med Phys; 2009 Jun; 36(6):2006-15. PubMed ID: 19610289
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.