These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 29849255)

  • 1. Gastric Outlet Obstruction Caused by Foley Catheter: A Complication when Substituting for Commercial Gastrostomy Tubes.
    Vu S; Lewis AB; Moore B
    Clin Pract Cases Emerg Med; 2018 Feb; 2(1):35-38. PubMed ID: 29849255
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Catheter traction and gastric outlet obstruction: a repeated complication of using a Foley catheter for gastrostomy tube replacement.
    Fonseca J; Nunes G; Patita M; Barosa R; Santos CA
    Nutr Hosp; 2017 Mar; 34(2):499-501. PubMed ID: 28421810
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Foley catheter as a replacement gastrostomy tube with commercial replacement gastrostomy tube: a prospective randomized trial.
    Kadakia SC; Cassaday M; Shaffer RT
    Gastrointest Endosc; 1994; 40(2 Pt 1):188-93. PubMed ID: 8013820
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Gastric outlet obstruction: An unusual adverse event of percutaneous endoscopic gastrostomy.
    Barosa R; Santos C; Fonseca J
    Rev Esp Enferm Dig; 2016 Jan; 108(1):53-4. PubMed ID: 26765241
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Prospective evaluation of Foley catheter as a replacement gastrostomy tube.
    Kadakia SC; Cassaday M; Shaffer RT
    Am J Gastroenterol; 1992 Nov; 87(11):1594-7. PubMed ID: 1442680
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Foley Catheters as Temporary Gastrostomy Tubes: Experience of a Nurse-Led Service.
    Metussin A; Sia R; Bakar S; Chong VH
    Gastroenterol Nurs; 2016; 39(4):273-7. PubMed ID: 27467058
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A Rare Case of Gastric Outlet Obstruction With Severe Reflux Esophagitis Due to a Percutaneous Endoscopic Gastrostomy Tube Balloon Displacement.
    Obeidat AE; Mahfouz R; Darweesh MR; Lim H
    Cureus; 2021 Oct; 13(10):e18635. PubMed ID: 34786233
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Problems with use of a Foley catheter in enteral tube feeding.
    Ojo O
    Br J Nurs; 2014 Apr 10-23; 23(7):360-2, 364. PubMed ID: 24732987
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Complication of a percutaneous endoscopic gastrostomy tube causing duodenal ischemia.
    Martel G; Lingas RI; Gutauskas A; Clark HD
    Surg Laparosc Endosc Percutan Tech; 2006 Dec; 16(6):445-6. PubMed ID: 17277666
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gastric Outlet and Duodenal Obstruction as a Complication of Migrated Gastrostomy Tube: Report of Two Cases and Literature Review.
    Shah J; Sunkara T; Yarlagadda KS; Rawla P; Gaduputi V
    Gastroenterology Res; 2018 Feb; 11(1):71-74. PubMed ID: 29511412
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Unusual complications of ballooned feeding tubes.
    Date RS; Das N; Bateson PG
    Ir Med J; 2002 Jun; 95(6):181-2. PubMed ID: 12171267
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Percutaneous endoscopic gastrostomy with jejunal extension plus percutaneous endoscopic gastrostomy (PEG-j plus PEG) in patients with gastric/duodenal cancer outlet obstruction.
    Fonseca J; Santos CA
    Arq Gastroenterol; 2015; 52(1):72-5. PubMed ID: 26017087
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Percutaneous transesophageal gastrostomy tube placement: an alternative to percutaneous endoscopic gastrostomy in patients with intra-abdominal metastasis.
    Singal AK; Dekovich AA; Tam AL; Wallace MJ
    Gastrointest Endosc; 2010 Feb; 71(2):402-6. PubMed ID: 20152318
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gastric Outlet Obstruction due to Malposition of Gastrostomy Tube: A Rare and Commonly Misdiagnosed Condition.
    Shah J; Shahidullah A
    Case Rep Gastroenterol; 2020; 14(2):409-414. PubMed ID: 32884518
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Duodenal obstruction: a complication of percutaneous endoscopic gastrostomy tube migration.
    McGovern R; Barkin JS; Goldberg RI; Phillips RS
    Am J Gastroenterol; 1990 Aug; 85(8):1037-8. PubMed ID: 2197857
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of complication rates, types, and average tube patency between jejunostomy tubes and percutaneous gastrostomy tubes in a regional home enteral nutrition support program.
    Ao P; Sebastianski M; Selvarajah V; Gramlich L
    Nutr Clin Pract; 2015 Jun; 30(3):393-7. PubMed ID: 25378355
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Retrograde coiled spring jejunal intussusception in an infant due to Foley catheter gastrostomy: a case report.
    Mehmetoğlu F
    BMC Gastroenterol; 2022 Jun; 22(1):283. PubMed ID: 35659585
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Gastrostomy tube dislodgment acute pancreatitis.
    Brauner E; Kluger Y
    World J Emerg Surg; 2014 Mar; 9(1):23. PubMed ID: 24674106
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Balloon gastrostomy tubes for long-term feeding in the community.
    Ojo O
    Br J Nurs; 2011 Jan 13-26; 20(1):34-8. PubMed ID: 21240137
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Duodenal obstruction by a nondeflating Foley catheter gastrostomy tube.
    O'Keefe KP; Dula DJ; Varano V
    Ann Emerg Med; 1990 Dec; 19(12):1454-7. PubMed ID: 2122777
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.