These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 29854364)

  • 1. Signal Space Separation Method for a Biomagnetic Sensor Array Arranged on a Flat Plane for Magnetocardiographic Applications: A Computer Simulation Study.
    Sekihara K
    J Healthc Eng; 2018; 2018():7689589. PubMed ID: 29854364
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effects of sensor calibration, balancing and parametrization on the signal space separation method.
    Nurminen J; Taulu S; Okada Y
    Phys Med Biol; 2008 Apr; 53(7):1975-87. PubMed ID: 18354243
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibration of a multichannel MEG system based on the signal space separation method.
    Chella F; Zappasodi F; Marzetti L; Della Penna S; Pizzella V
    Phys Med Biol; 2012 Aug; 57(15):4855-70. PubMed ID: 22797687
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improving MEG performance with additional tangential sensors.
    Nurminen J; Taulu S; Nenonen J; Helle L; Simola J; Ahonen A
    IEEE Trans Biomed Eng; 2013 Sep; 60(9):2559-66. PubMed ID: 23649129
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Improving the performance of the signal space separation method by comprehensive spatial sampling.
    Nurminen J; Taulu S; Okada Y
    Phys Med Biol; 2010 Mar; 55(5):1491-503. PubMed ID: 20157231
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of signal space separation via simulation.
    Song T; Gaa K; Cui L; Feffer L; Lee RR; Huang M
    Med Biol Eng Comput; 2008 Sep; 46(9):923-32. PubMed ID: 18196307
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Optimization of Signal Space Separation for Optically Pumped Magnetometer in Magnetoencephalography.
    Wang R; Wu H; Liang X; Cao F; Xiang M; Gao Y; Ning X
    Brain Topogr; 2023 May; 36(3):350-370. PubMed ID: 37046041
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Application of decorrelation-independent component analysis to biomagnetic multi-channel measurements.
    Sander TH; Burghoff M; Van Leeuwen P; Trahms L
    Biomed Tech (Berl); 2007 Feb; 52(1):130-6. PubMed ID: 17313349
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Extended Signal-Space Separation Method for Improved Interference Suppression in MEG.
    Helle L; Nenonen J; Larson E; Simola J; Parkkonen L; Taulu S
    IEEE Trans Biomed Eng; 2021 Jul; 68(7):2211-2221. PubMed ID: 33232223
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomagnetic measurement system for supine subjects with expanded sensor array and real-time noise reduction.
    Adachi Y; Kawabata S; Sasano T; Oyama YH; Uehara G; Sekihara K
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():7071-4. PubMed ID: 26737921
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Suppression of interference and artifacts by the Signal Space Separation Method.
    Taulu S; Kajola M; Simola J
    Brain Topogr; 2004; 16(4):269-75. PubMed ID: 15379226
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Beamspace magnetoencephalographic signal decomposition in spherical harmonics domain.
    Ozkurt TE; Sun M; Sclabassi RJ
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5743-6. PubMed ID: 17946327
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Noise-free magnetoencephalography recordings of brain function.
    Volegov P; Matlachov A; Mosher J; Espy MA; Kraus RH
    Phys Med Biol; 2004 May; 49(10):2117-28. PubMed ID: 15214546
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Analysis of chaos attractors of MCG-recordings.
    Jiang S; Yang F; Yi P; Chen B; Luo M; Wang L
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():6153-6. PubMed ID: 17946743
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rejection of artifact sources in magnetoencephalogram background activity using independent component analysis.
    Escudero J; Hornero R; Abásolo D; Poza J; Fernández A; López M
    Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5282-5. PubMed ID: 17945889
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Signal-to-noise ratio of the MEG signal after preprocessing.
    Gonzalez-Moreno A; Aurtenetxe S; Lopez-Garcia ME; del Pozo F; Maestu F; Nevado A
    J Neurosci Methods; 2014 Jan; 222():56-61. PubMed ID: 24200506
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Artifact and head movement compensation in MEG.
    Medvedovsky M; Taulu S; Bikmullina R; Paetau R
    Neurol Neurophysiol Neurosci; 2007 Oct; ():4. PubMed ID: 18066426
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dual signal subspace projection (DSSP): a novel algorithm for removing large interference in biomagnetic measurements.
    Sekihara K; Kawabata Y; Ushio S; Sumiya S; Kawabata S; Adachi Y; Nagarajan SS
    J Neural Eng; 2016 Jun; 13(3):036007. PubMed ID: 27064933
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Toward noninvasive monitoring of ongoing electrical activity of human uterus and fetal heart and brain.
    Lew S; Hämäläinen MS; Okada Y
    Clin Neurophysiol; 2017 Dec; 128(12):2470-2481. PubMed ID: 29100065
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Signal space separation algorithm and its application on suppressing artifacts caused by vagus nerve stimulation for magnetoencephalography recordings.
    Song T; Cui L; Gaa K; Feffer L; Taulu S; Lee RR; Huang M
    J Clin Neurophysiol; 2009 Dec; 26(6):392-400. PubMed ID: 19952563
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.