BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 29856489)

  • 1. Accelerated image reconstruction using extrapolated Tikhonov filtering for photoacoustic tomography.
    Gutta S; Kalva SK; Pramanik M; Yalavarthy PK
    Med Phys; 2018 Jun; ():. PubMed ID: 29856489
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computationally efficient error estimate for evaluation of regularization in photoacoustic tomography.
    Bhatt M; Acharya A; Yalavarthy PK
    J Biomed Opt; 2016 Oct; 21(10):106002. PubMed ID: 27762422
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Image-guided filtering for improving photoacoustic tomographic image reconstruction.
    Awasthi N; Kalva SK; Pramanik M; Yalavarthy PK
    J Biomed Opt; 2018 Jun; 23(9):1-22. PubMed ID: 29943527
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Exponential filtering of singular values improves photoacoustic image reconstruction.
    Bhatt M; Gutta S; Yalavarthy PK
    J Opt Soc Am A Opt Image Sci Vis; 2016 Sep; 33(9):1785-92. PubMed ID: 27607501
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Fractional Regularization to Improve Photoacoustic Tomographic Image Reconstruction.
    Prakash J; Sanny D; Kalva SK; Pramanik M; Yalavarthy PK
    IEEE Trans Med Imaging; 2019 Aug; 38(8):1935-1947. PubMed ID: 30582534
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Basis pursuit deconvolution for improving model-based reconstructed images in photoacoustic tomography.
    Prakash J; Raju AS; Shaw CB; Pramanik M; Yalavarthy PK
    Biomed Opt Express; 2014 May; 5(5):1363-77. PubMed ID: 24877001
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.
    Awasthi N; Kalva SK; Pramanik M; Yalavarthy PK
    J Biomed Opt; 2018 Feb; 23(7):1-11. PubMed ID: 29405050
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Spatially variant regularization based on model resolution and fidelity embedding characteristics improves photoacoustic tomography.
    Sanny DR; Prakash J; Kalva SK; Pramanik M; Yalavarthy PK
    J Biomed Opt; 2018 Oct; 23(10):1-4. PubMed ID: 30362308
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A novel combined regularization algorithm of total variation and Tikhonov regularization for open electrical impedance tomography.
    Liu J; Ling L; Li G
    Physiol Meas; 2013 Jul; 34(7):823-38. PubMed ID: 23787806
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of the Tikhonov Regularization Parameter on the Accuracy of the Inverse Problem in Electrocardiography.
    Wang T; Karel J; Bonizzi P; Peeters RLM
    Sensors (Basel); 2023 Feb; 23(4):. PubMed ID: 36850438
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A LSQR-type method provides a computationally efficient automated optimal choice of regularization parameter in diffuse optical tomography.
    Prakash J; Yalavarthy PK
    Med Phys; 2013 Mar; 40(3):033101. PubMed ID: 23464341
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Image reconstruction based on L1 regularization and projection methods for electrical impedance tomography.
    Wang Q; Wang H; Zhang R; Wang J; Zheng Y; Cui Z; Yang C
    Rev Sci Instrum; 2012 Oct; 83(10):104707. PubMed ID: 23126790
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography.
    Feng J; Qin C; Jia K; Han D; Liu K; Zhu S; Yang X; Tian J
    Med Phys; 2011 Nov; 38(11):5933-44. PubMed ID: 22047358
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Least squares QR-based decomposition provides an efficient way of computing optimal regularization parameter in photoacoustic tomography.
    Shaw CB; Prakash J; Pramanik M; Yalavarthy PK
    J Biomed Opt; 2013 Aug; 18(8):80501. PubMed ID: 23903561
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Learned regularization for image reconstruction in sparse-view photoacoustic tomography.
    Wang T; He M; Shen K; Liu W; Tian C
    Biomed Opt Express; 2022 Nov; 13(11):5721-5737. PubMed ID: 36733736
    [TBL] [Abstract][Full Text] [Related]  

  • 16. On Tikhonov regularization for image reconstruction in parallel MRI.
    Ying L; Xu D; Liang ZP
    Conf Proc IEEE Eng Med Biol Soc; 2004; 2004():1056-9. PubMed ID: 17271864
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hybrid method for improving Tikhonov-based reconstruction quality in electrical impedance tomography.
    Wang M; Zheng S; Shi Y; Lou Y
    J Med Imaging (Bellingham); 2022 Sep; 9(5):054503. PubMed ID: 36267548
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Dimensionality reduced plug and play priors for improving photoacoustic tomographic imaging with limited noisy data.
    Awasthi N; Kumar Kalva S; Pramanik M; Yalavarthy PK
    Biomed Opt Express; 2021 Mar; 12(3):1320-1338. PubMed ID: 33796356
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An adaptive Tikhonov regularization method for fluorescence molecular tomography.
    Cao X; Zhang B; Wang X; Liu F; Liu K; Luo J; Bai J
    Med Biol Eng Comput; 2013 Aug; 51(8):849-58. PubMed ID: 23504309
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Tikhonov regularization-based extended Kalman filter technique for robust and accurate reconstruction in diffuse optical tomography.
    Zhang J; Zhang L; Liu Z; Zhang Y; Liu D; Jia M; Gao F
    J Opt Soc Am A Opt Image Sci Vis; 2023 Jan; 40(1):10-20. PubMed ID: 36607070
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.