1. Towards eradication of inappropriate therapies for ICD lead failure by combining comprehensive remote monitoring and lead noise alerts. Ploux S; Swerdlow CD; Strik M; Welte N; Klotz N; Ritter P; Haïssaguerre M; Bordachar P J Cardiovasc Electrophysiol; 2018 Aug; 29(8):1125-1134. PubMed ID: 29858871 [TBL] [Abstract][Full Text] [Related]
2. Lead integrity alert algorithm decreases inappropriate shocks in patients who have Sprint Fidelis pace-sense conductor fractures. Kallinen LM; Hauser RG; Tang C; Melby DP; Almquist AK; Katsiyiannis WT; Gornick CC Heart Rhythm; 2010 Aug; 7(8):1048-55. PubMed ID: 20493965 [TBL] [Abstract][Full Text] [Related]
3. Performance of an ICD algorithm to detect lead noise and reduce inappropriate shocks. Beau S; Greer S; Ellis CR; Keeney J; Asopa S; Arnold E; Fischer A J Interv Card Electrophysiol; 2016 Mar; 45(2):225-32. PubMed ID: 26739482 [TBL] [Abstract][Full Text] [Related]
4. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure. Spencker S; Coban N; Koch L; Schirdewan A; Müller D Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654 [TBL] [Abstract][Full Text] [Related]
5. Failure of impedance monitoring to prevent adverse clinical events caused by fracture of a recalled high-voltage implantable cardioverter-defibrillator lead. Kallinen LM; Hauser RG; Lee KW; Almquist AK; Katsiyiannis WT; Tang CY; Melby DP; Gornick CC Heart Rhythm; 2008 Jun; 5(6):775-9. PubMed ID: 18534361 [TBL] [Abstract][Full Text] [Related]
6. Automatic R-wave and impedance testing with the modern patient alert system to reduce inappropriate implantable cardioverter defibrillator shocks due to lead fracture. Chinushi M; Hosaka Y; Ikarashi N; Iijima K; Furushima H; Aizawa Y Europace; 2008 Jun; 10(6):738-40. PubMed ID: 18390874 [TBL] [Abstract][Full Text] [Related]
7. Prevention of inappropriate ICD shocks due to lead insulation failure by continuous monitoring and automatic alert. Gelder RN; Gunderson BD Pacing Clin Electrophysiol; 2012 Jun; 35(6):e150-3. PubMed ID: 22309317 [TBL] [Abstract][Full Text] [Related]
8. Limitation of programmed alerts to predict ICD lead failures. Vlay SC Pacing Clin Electrophysiol; 2009 Apr; 32(4):554-5. PubMed ID: 19335870 [TBL] [Abstract][Full Text] [Related]
9. Impact of remote monitoring on reducing the burden of inappropriate shocks related to implantable cardioverter-defibrillator lead fractures: insights from a French single-centre registry. Souissi Z; Guédon-Moreau L; Boulé S; Kouakam C; Finat L; Marquié C; Brigadeau F; Wissocque L; Mouton S; Montaigne D; Klug D; Kacet S; Lacroix D Europace; 2016 Jun; 18(6):820-7. PubMed ID: 26498163 [TBL] [Abstract][Full Text] [Related]
10. Performance of Lead Integrity Alert to assist in the clinical diagnosis of implantable cardioverter defibrillator lead failures: analysis of different implantable cardioverter defibrillator leads. Ellenbogen KA; Gunderson BD; Stromberg KD; Swerdlow CD Circ Arrhythm Electrophysiol; 2013 Dec; 6(6):1169-77. PubMed ID: 24099976 [TBL] [Abstract][Full Text] [Related]
11. Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms. Vollmann D; Erdogan A; Himmrich E; Neuzner J; Becker D; Unterberg-Buchwald C; Sperzel J Europace; 2006 May; 8(5):371-6. PubMed ID: 16635998 [TBL] [Abstract][Full Text] [Related]
13. Potential role of antitachycardia pacing alerts for the reduction of emergency presentations following shocks in patients with implantable cardioverter-defibrillators: implications for the implementation of remote monitoring. Boulé S; Ninni S; Finat L; Botcherby EJ; Kouakam C; Klug D; Marquié C; Brigadeau F; Lacroix D; Kacet S; Guédon-Moreau L Europace; 2016 Dec; 18(12):1809-1817. PubMed ID: 26711741 [TBL] [Abstract][Full Text] [Related]