These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
6. On-Chip Platelet Activation Assessment: Microfluidic Emulation of Shear Stress Profiles Induced by Mechanical Circulatory Support Devices. Mencarini T; Bozzi S; Redaelli A Methods Mol Biol; 2022; 2373():201-212. PubMed ID: 34520014 [TBL] [Abstract][Full Text] [Related]
7. Microfludic platforms for the evaluation of anti-platelet agent efficacy under hyper-shear conditions associated with ventricular assist devices. Dimasi A; Rasponi M; Consolo F; Fiore GB; Bluestein D; Slepian MJ; Redaelli A Med Eng Phys; 2017 Oct; 48():31-38. PubMed ID: 28869117 [TBL] [Abstract][Full Text] [Related]
13. Detection of activated platelets in canine blood by use of flow cytometry. Wills TB; Wardrop KJ; Meyers KM Am J Vet Res; 2006 Jan; 67(1):56-63. PubMed ID: 16426212 [TBL] [Abstract][Full Text] [Related]
14. Paradoxical Effect of Nonphysiological Shear Stress on Platelets and von Willebrand Factor. Chen Z; Mondal NK; Ding J; Koenig SC; Slaughter MS; Wu ZJ Artif Organs; 2016 Jul; 40(7):659-68. PubMed ID: 26582038 [TBL] [Abstract][Full Text] [Related]
15. Constricted microfluidic devices to study the effects of transient high shear exposure on platelets. Alsmadi NZ; Shapiro SJ; Lewis CS; Sheth VM; Snyder TA; Schmidtke DW Biomicrofluidics; 2017 Nov; 11(6):064105. PubMed ID: 29204246 [TBL] [Abstract][Full Text] [Related]
16. Effects of upstream shear forces on priming of platelets for downstream adhesion and activation. Rahman SM; Eichinger CD; Hlady V Acta Biomater; 2018 Jun; 73():228-235. PubMed ID: 29654993 [TBL] [Abstract][Full Text] [Related]
17. Effects of physiologically relevant dynamic shear stress on platelet complement activation. Shanmugavelayudam SK; Rubenstein DA; Yin W Platelets; 2011; 22(8):602-10. PubMed ID: 21679034 [TBL] [Abstract][Full Text] [Related]
18. High shear induces platelet dysfunction leading to enhanced thrombotic propensity and diminished hemostatic capacity. Chen Z; Mondal NK; Zheng S; Koenig SC; Slaughter MS; Griffith BP; Wu ZJ Platelets; 2019; 30(1):112-119. PubMed ID: 29182470 [TBL] [Abstract][Full Text] [Related]
19. Shear-induced platelet receptor shedding by non-physiological high shear stress with short exposure time: glycoprotein Ibα and glycoprotein VI. Chen Z; Mondal NK; Ding J; Gao J; Griffith BP; Wu ZJ Thromb Res; 2015 Apr; 135(4):692-8. PubMed ID: 25677981 [TBL] [Abstract][Full Text] [Related]
20. Platelet activation due to hemodynamic shear stresses: damage accumulation model and comparison to in vitro measurements. Nobili M; Sheriff J; Morbiducci U; Redaelli A; Bluestein D ASAIO J; 2008; 54(1):64-72. PubMed ID: 18204318 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]