These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 29885635)

  • 1. Detecting illegal intra-corporeal cocaine containers: Which factors influence their density?
    Platon A; Herrera B; Becker M; Perneger T; Getaz L; Wolff H; Lock E; Rutschmann O; Poletti PA
    Clin Imaging; 2018; 51():235-239. PubMed ID: 29885635
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Illegal intra-corporeal packets: can dual energy CT be used for the evaluation of cocaine concentration? A cross sectional study.
    Platon A; Becker M; Becker CD; Lock E; Wolff H; Perneger T; Poletti PA
    BMC Med Imaging; 2016 Jan; 16():3. PubMed ID: 26762344
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Screening of illegal intracorporeal containers ("body packing"): is abdominal radiography sufficiently accurate? A comparative study with low-dose CT.
    Poletti PA; Canel L; Becker CD; Wolff H; Elger B; Lock E; Sarasin F; Bonfanti MS; Dupuis-Lozeron E; Perneger T; Platon A
    Radiology; 2012 Dec; 265(3):772-9. PubMed ID: 22952384
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Swallowed opium packets: CT diagnosis.
    Taheri MS; Hassanian-Moghaddam H; Birang S; Hemadi H; Shahnazi M; Jalali AH; Shakiba M; Nahvi V
    Abdom Imaging; 2008; 33(3):262-6. PubMed ID: 17610106
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Low-dose computed tomography to detect body-packing in an animal model.
    Maurer MH; Niehues SM; Schnapauff D; Grieser C; Rothe JH; Waldmüller D; Chopra SS; Hamm B; Denecke T
    Eur J Radiol; 2011 May; 78(2):302-6. PubMed ID: 20889275
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Body packers on your examination table: How helpful are plain x-ray images? A definitive low-dose CT protocol as a diagnosis tool for body packers.
    Schulz B; Grossbach A; Gruber-Rouh T; Zangos S; Vogl TJ; Eichler K
    Clin Radiol; 2014 Dec; 69(12):e525-30. PubMed ID: 25300556
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiographic features of intracorporeally smuggled liquid cocaine.
    Mozes O; Guranda L; Portnoy O; Apter S; Konen E; Amitai MM
    Forensic Sci Med Pathol; 2014 Dec; 10(4):535-42. PubMed ID: 25326675
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Detection of residual packets in cocaine body packers: low accuracy of abdominal radiography-a prospective study.
    Rousset P; Chaillot PF; Audureau E; Rey-Salmon C; Becour B; Fitton I; Vadrot D; Revel MP
    Eur Radiol; 2013 Aug; 23(8):2146-55. PubMed ID: 23508274
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Low-tube voltage 100 kVp MDCT in screening of cocaine body packing: image quality and radiation dose compared to 120 kVp MDCT.
    Aissa J; Rubbert C; Boos J; Schleich C; Thomas C; Kröpil P; Antoch G; Miese F
    Abdom Imaging; 2015 Oct; 40(7):2152-8. PubMed ID: 26048697
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The role of ultrasonography in the imaging of body packers comparison with CT: a prospective study.
    Cengel F; Bulakci M; Selcuk T; Savas Y; Ceyhan M; Kocak A; Bilgili CO
    Abdom Imaging; 2015 Oct; 40(7):2143-51. PubMed ID: 25906342
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Noise insertion in CT for cocaine body packing: where is the limit of extensive dose reduction?
    Aissa J; Bölke E; Sawicki LM; Appel E; Thomas C; Heusch P; Sedlmair M; Krzymyk K; Kröpil P; Antoch G; Boos J
    Eur J Med Res; 2018 Dec; 23(1):59. PubMed ID: 30526681
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Detection of ingested cocaine-filled packets--diagnostic value of unenhanced CT.
    Schmidt S; Hugli O; Rizzo E; Lepori D; Gudinchet F; Yersin B; Schnyder P; Meuwly JY
    Eur J Radiol; 2008 Jul; 67(1):133-8. PubMed ID: 17768023
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Diagnostic imaging of "body packers"].
    Ichikawa K; Tajima N; Tajima H; Murakami R; Okada S; Hosaka J; Ito K; Yamamoto K; Kumazaki T; Masuno T; Yokota H; Makino T
    Nihon Igaku Hoshasen Gakkai Zasshi; 1997 Feb; 57(3):89-93. PubMed ID: 9077088
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison of diagnostic value of multidetector computed tomography and X-ray in the detection of body packing.
    Bulakci M; Kalelioglu T; Bulakci BB; Kiris A
    Eur J Radiol; 2013 Aug; 82(8):1248-54. PubMed ID: 23357250
    [TBL] [Abstract][Full Text] [Related]  

  • 15. "Drug mules" as a radiological challenge: sensitivity and specificity in identifying internal cocaine in body packers, body pushers and body stuffers by computed tomography, plain radiography and Lodox.
    Flach PM; Ross SG; Ampanozi G; Ebert L; Germerott T; Hatch GM; Thali MJ; Patak MA
    Eur J Radiol; 2012 Oct; 81(10):2518-26. PubMed ID: 22178312
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Non-fatal rupture of a cocaine packet in a man with the 'bodypacker' syndrome].
    Haveman JW; Sonneveld DJ; Uges DR; Delwig H; Zijlstra JG
    Ned Tijdschr Geneeskd; 2002 Nov; 146(47):2246-50. PubMed ID: 12481521
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The body packer syndrome--cocaine smuggling in the gastro-intestinal tract.
    Hartoko TJ; Demey HE; De Schepper AM; Beaucourt LE; Bossaert LL
    Klin Wochenschr; 1988 Nov; 66(22):1116-20. PubMed ID: 3236761
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Plain radiography may underestimate the burden of body packer ingestion: A case report.
    Esterson YB; Patel V; Nicastro J; Friedman B
    Clin Imaging; 2017; 44():57-60. PubMed ID: 28441549
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cocaine by internal mail.
    Bycroft J
    J R Soc Med; 2003 Jun; 96(6):315. PubMed ID: 12782705
    [No Abstract]   [Full Text] [Related]  

  • 20. Foreign objects encountered in the abdominal cavity at CT.
    Gayer G; Petrovitch I; Jeffrey RB
    Radiographics; 2011; 31(2):409-28. PubMed ID: 21415187
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.