3. Screw-tip augmentation versus standard locked plating of displaced proximal humeral fractures: a retrospective comparative cohort study. Siebenbürger G; Helfen T; Biermann N; Haasters F; Böcker W; Ockert B J Shoulder Elbow Surg; 2019 Jul; 28(7):1326-1333. PubMed ID: 31056395 [TBL] [Abstract][Full Text] [Related]
4. Screw-Tip Augmented Locked Plating Versus Primary Reverse Total Shoulder Arthroplasty in Displaced Proximal Humeral Fractures: A Retrospective Comparative Cohort Study With a Mean Follow-Up of 39 Months. Siebenbürger G; Fleischhacker E; Stumpf U; Helfen T; Böcker W; Ockert B Geriatr Orthop Surg Rehabil; 2021; 12():21514593211039026. PubMed ID: 35070475 [TBL] [Abstract][Full Text] [Related]
5. Does cement augmentation of the screws in angular stable plating for proximal humerus fractures influence the radiological outcome: a retrospective assessment. Knierzinger D; Crepaz-Eger U; Hengg C; Kralinger F Arch Orthop Trauma Surg; 2020 Oct; 140(10):1413-1421. PubMed ID: 32130479 [TBL] [Abstract][Full Text] [Related]
6. Locked plating of 3- and 4-part proximal humerus fractures in older patients: the effect of initial fracture pattern on outcome. Solberg BD; Moon CN; Franco DP; Paiement GD J Orthop Trauma; 2009 Feb; 23(2):113-9. PubMed ID: 19169103 [TBL] [Abstract][Full Text] [Related]
7. Second generation locked plating for complex proximal humerus fractures in very elderly patients. Gavaskar AS; Karthik B B; Tummala NC; Srinivasan P; Gopalan H Injury; 2016 Nov; 47(11):2534-2538. PubMed ID: 27594168 [TBL] [Abstract][Full Text] [Related]
8. Arthroscopy after locked plating of proximal humeral fractures: implant removal, capsular release, and intra-articular findings. Katthagen JC; Hennecke D; Jensen G; Ellwein A; Voigt C; Lill H Arthroscopy; 2014 Sep; 30(9):1061-7. PubMed ID: 24939364 [TBL] [Abstract][Full Text] [Related]
9. The importance of medial support in locked plating of proximal humerus fractures. Gardner MJ; Weil Y; Barker JU; Kelly BT; Helfet DL; Lorich DG J Orthop Trauma; 2007 Mar; 21(3):185-91. PubMed ID: 17473755 [TBL] [Abstract][Full Text] [Related]
10. Is loss of fixation following locked plating of proximal humeral fractures related to the number of screws and their positions in the humeral head? Maddah M; Prall WC; Geyer L; Wirth S; Mutschler W; Ockert B Orthop Rev (Pavia); 2014 Apr; 6(2):5336. PubMed ID: 25002940 [TBL] [Abstract][Full Text] [Related]
11. Double Plating for Complex Proximal Humeral Fractures: Clinical and Radiological Outcomes. Michel PA; Raschke MJ; Katthagen JC; Schliemann B; Reißberg I; Riesenbeck O J Clin Med; 2023 Jan; 12(2):. PubMed ID: 36675625 [TBL] [Abstract][Full Text] [Related]
12. Feasibility and Radiological Outcome of Minimally Invasive Locked Plating of Proximal Humeral Fractures in Geriatric Patients. Schuetze K; Boehringer A; Cintean R; Gebhard F; Pankratz C; Richter PH; Schneider M; Eickhoff AM J Clin Med; 2022 Nov; 11(22):. PubMed ID: 36431230 [TBL] [Abstract][Full Text] [Related]
13. Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: analysis of a prospective randomized study. Ockert B; Pedersen V; Geyer L; Wirth S; Mutschler W; Grote S Eur J Orthop Surg Traumatol; 2014 Jul; 24(5):747-52. PubMed ID: 24253956 [TBL] [Abstract][Full Text] [Related]
14. Timing of surgery for open reduction and internal fixation of displaced proximal humeral fractures. Siebenbürger G; Van Delden D; Helfen T; Haasters F; Böcker W; Ockert B Injury; 2015 Oct; 46 Suppl 4():S58-62. PubMed ID: 26542867 [TBL] [Abstract][Full Text] [Related]
15. The results of tension band rotator cuff suture fixation of locked plating of displaced proximal humerus fractures. Shukla DR; McAnany S; Pean C; Overley S; Lovy A; Parsons BO Injury; 2017 Feb; 48(2):474-480. PubMed ID: 28063677 [TBL] [Abstract][Full Text] [Related]
16. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures. Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H Clin Biomech (Bristol); 2014 Aug; 29(7):735-41. PubMed ID: 24997810 [TBL] [Abstract][Full Text] [Related]
17. Varus malposition relates to functional outcomes following open reduction and internal fixation for proximal humeral fractures: A retrospective comparative cohort study with minimum 2 years follow-up. Fleischhacker E; Siebenbürger G; Helfen T; Gleich J; Böcker W; Ockert B Injury; 2021 Mar; 52(3):506-510. PubMed ID: 32917384 [TBL] [Abstract][Full Text] [Related]
18. Are polyaxially locked screws advantageous in the plate osteosynthesis of proximal humeral fractures in the elderly? A prospective randomized clinical observational study. Voigt C; Geisler A; Hepp P; Schulz AP; Lill H J Orthop Trauma; 2011 Oct; 25(10):596-602. PubMed ID: 21670709 [TBL] [Abstract][Full Text] [Related]
19. Fracture site augmentation with calcium phosphate cement reduces screw penetration after open reduction-internal fixation of proximal humeral fractures. Egol KA; Sugi MT; Ong CC; Montero N; Davidovitch R; Zuckerman JD J Shoulder Elbow Surg; 2012 Jun; 21(6):741-8. PubMed ID: 22192764 [TBL] [Abstract][Full Text] [Related]
20. Geriatric proximal humeral fracture patients show similar clinical outcomes to non-geriatric patients after osteosynthesis with endosteal fibular strut allograft augmentation. Hinds RM; Garner MR; Tran WH; Lazaro LE; Dines JS; Lorich DG J Shoulder Elbow Surg; 2015 Jun; 24(6):889-96. PubMed ID: 25483905 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]