These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
177 related articles for article (PubMed ID: 29891030)
1. The history of proximal carotid protection and flow reversal to prevent stent angioplasty embolization. Parodi J; Bates MC; Ohki T; Schönholz C Semin Vasc Surg; 2018 Mar; 31(1):9-14. PubMed ID: 29891030 [TBL] [Abstract][Full Text] [Related]
2. A Prospective, Multicenter Study of a Novel Mesh-Covered Carotid Stent: The CGuard CARENET Trial (Carotid Embolic Protection Using MicroNet). Schofer J; Musiałek P; Bijuklic K; Kolvenbach R; Trystula M; Siudak Z; Sievert H JACC Cardiovasc Interv; 2015 Aug; 8(9):1229-1234. PubMed ID: 26292586 [TBL] [Abstract][Full Text] [Related]
3. Technique and clinical evidence of neuroprotection in carotid artery stenting. Knur R Vasa; 2014 Mar; 43(2):100-12. PubMed ID: 24627316 [TBL] [Abstract][Full Text] [Related]
4. Embolic protection in carotid artery stenting: "a no-brainer"? Macdonald S J Cardiovasc Surg (Torino); 2010 Dec; 51(6):861-4. PubMed ID: 21124283 [No Abstract] [Full Text] [Related]
5. Will mesh-covered stents help reduce stroke associated with carotid stent angioplasty? Richards CN; Schneider PA Semin Vasc Surg; 2017 Mar; 30(1):25-30. PubMed ID: 28818256 [TBL] [Abstract][Full Text] [Related]
6. The incidence of microemboli to the brain is less with endarterectomy than with percutaneous revascularization with distal filters or flow reversal. Gupta N; Corriere MA; Dodson TF; Chaikof EL; Beaulieu RJ; Reeves JG; Salam AA; Kasirajan K J Vasc Surg; 2011 Feb; 53(2):316-22. PubMed ID: 21129899 [TBL] [Abstract][Full Text] [Related]
7. New technologies for CAS that might overcome the burden of microembolization. Yamada R; Guimaraes M; Adams J; Schönholz C J Cardiovasc Surg (Torino); 2015 Dec; 56(6):859-65. PubMed ID: 26173393 [TBL] [Abstract][Full Text] [Related]
8. Safety and feasibility of a novel transcervical access neuroprotection system for carotid artery stenting in the PROOF Study. Pinter L; Ribo M; Loh C; Lane B; Roberts T; Chou TM; Kolvenbach RR J Vasc Surg; 2011 Nov; 54(5):1317-23. PubMed ID: 21658889 [TBL] [Abstract][Full Text] [Related]
16. Assessment of reverse flow as a means of cerebral protection during carotid artery stent placement with diffusion-weighted and transcranial Doppler imaging. Goode SD; Hoggard N; Macdonald S; Evans DH; Cleveland TJ; Gaines PA J Vasc Interv Radiol; 2013 Apr; 24(4):528-33. PubMed ID: 23462063 [TBL] [Abstract][Full Text] [Related]
17. Analysis of the ROADSTER pivotal and extended-access cohorts shows excellent 1-year durability of transcarotid stenting with dynamic flow reversal. Malas MB; Leal Lorenzo JI; Nejim B; Hanover TM; Mehta M; Kashyap V; Kwolek CJ; Cambria R J Vasc Surg; 2019 Jun; 69(6):1786-1796. PubMed ID: 30611582 [TBL] [Abstract][Full Text] [Related]
18. Angioplasty and stenting of the cervical carotid artery with embolic protection of the cerebral circulation. Technol Eval Cent Assess Program Exec Summ; 2010 Aug; 24(12):1-3. PubMed ID: 21114063 [No Abstract] [Full Text] [Related]