These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
675 related articles for article (PubMed ID: 29900633)
1. Isolation and molecular analysis of circulating tumor cells from lung cancer patients using a microfluidic chip type cell sorter. Watanabe M; Kenmotsu H; Ko R; Wakuda K; Ono A; Imai H; Taira T; Naito T; Murakami H; Abe M; Endo M; Nakajima T; Koh Y; Takahashi T Cancer Sci; 2018 Aug; 109(8):2539-2548. PubMed ID: 29900633 [TBL] [Abstract][Full Text] [Related]
2. Detection of circulating tumor cells in patients with lung cancer using a rare cell sorter: a pilot study. Sugai K; Mori T; Bilal T; Furukawa A; Sekine Y; Kobayashi N; Kikuchi S; Goto Y; Ichimura H; Masuda T; Arai F; Sato Y; Matsusaka S BMC Cancer; 2024 Oct; 24(1):1291. PubMed ID: 39425044 [TBL] [Abstract][Full Text] [Related]
3. A novel flow cytometry-based cell capture platform for the detection, capture and molecular characterization of rare tumor cells in blood. Watanabe M; Serizawa M; Sawada T; Takeda K; Takahashi T; Yamamoto N; Koizumi F; Koh Y J Transl Med; 2014 May; 12():143. PubMed ID: 24886394 [TBL] [Abstract][Full Text] [Related]
4. Nanoroughened adhesion-based capture of circulating tumor cells with heterogeneous expression and metastatic characteristics. Chen W; Allen SG; Reka AK; Qian W; Han S; Zhao J; Bao L; Keshamouni VG; Merajver SD; Fu J BMC Cancer; 2016 Aug; 16():614. PubMed ID: 27501846 [TBL] [Abstract][Full Text] [Related]
5. Size-based isolation of circulating tumor cells in lung cancer patients using a microcavity array system. Hosokawa M; Kenmotsu H; Koh Y; Yoshino T; Yoshikawa T; Naito T; Takahashi T; Murakami H; Nakamura Y; Tsuya A; Shukuya T; Ono A; Akamatsu H; Watanabe R; Ono S; Mori K; Kanbara H; Yamaguchi K; Tanaka T; Matsunaga T; Yamamoto N PLoS One; 2013; 8(6):e67466. PubMed ID: 23840710 [TBL] [Abstract][Full Text] [Related]
6. Sensitive cytometry based system for enumeration, capture and analysis of gene mutations of circulating tumor cells. Sawada T; Watanabe M; Fujimura Y; Yagishita S; Shimoyama T; Maeda Y; Kanda S; Yunokawa M; Tamura K; Tamura T; Minami H; Koh Y; Koizumi F Cancer Sci; 2016 Mar; 107(3):307-14. PubMed ID: 26708016 [TBL] [Abstract][Full Text] [Related]
7. A prospective examination of circulating tumor cell profiles in non-small-cell lung cancer molecular subgroups. Lindsay CR; Faugeroux V; Michiels S; Pailler E; Facchinetti F; Ou D; Bluthgen MV; Pannet C; Ngo-Camus M; Bescher G; Caramella C; Billiot F; Remon J; Planchard D; Soria JC; Besse B; Farace F Ann Oncol; 2017 Jul; 28(7):1523-1531. PubMed ID: 28633480 [TBL] [Abstract][Full Text] [Related]
8. Analysis of circulating tumor cells in patients with non-small cell lung cancer using epithelial marker-dependent and -independent approaches. Krebs MG; Hou JM; Sloane R; Lancashire L; Priest L; Nonaka D; Ward TH; Backen A; Clack G; Hughes A; Ranson M; Blackhall FH; Dive C J Thorac Oncol; 2012 Feb; 7(2):306-15. PubMed ID: 22173704 [TBL] [Abstract][Full Text] [Related]
9. Polymer nanofiber-based microchips for EGFR mutation analysis of circulating tumor cells in lung adenocarcinoma. Jiang W; Wang H; Cui Y; Lei Y; Wang Y; Xu D; Jiang N; Chen Y; Sun Y; Zhang Y; Cao J; Ke Z Int J Nanomedicine; 2018; 13():1633-1642. PubMed ID: 29588590 [TBL] [Abstract][Full Text] [Related]
10. Prognostic impact of circulating tumor cells detected with the microfluidic "universal CTC-chip" for primary lung cancer. Kanayama M; Kuwata T; Mori M; Nemoto Y; Nishizawa N; Oyama R; Matsumiya H; Taira A; Shinohara S; Takenaka M; Yoneda K; Kuroda K; Ohnaga T; Tanaka F Cancer Sci; 2022 Mar; 113(3):1028-1037. PubMed ID: 34964211 [TBL] [Abstract][Full Text] [Related]
11. EGFR mutation detection of lung circulating tumor cells using a multifunctional microfluidic chip. Wang Y; Gao W; Wu M; Zhang X; Liu W; Zhou Y; Jia C; Cong H; Chen X; Zhao J Talanta; 2021 Apr; 225():122057. PubMed ID: 33592778 [TBL] [Abstract][Full Text] [Related]
12. Detection of circulating tumor cells with a novel microfluidic system in malignant pleural mesothelioma. Yoneda K; Kuwata T; Chikaishi Y; Mori M; Kanayama M; Takenaka M; Oka S; Hirai A; Imanishi N; Kuroda K; Ichiki Y; Ohnaga T; Tanaka F Cancer Sci; 2019 Feb; 110(2):726-733. PubMed ID: 30499156 [TBL] [Abstract][Full Text] [Related]
13. A Modified Method to Isolate Circulating Tumor Cells and Identify by a Panel of Gene Mutations in Lung Cancer. Wang H; Wu J; Zhang Q; Hao J; Wang Y; Li Z; Niu H; Zhang H; Zhang S Technol Cancer Res Treat; 2021; 20():1533033821995275. PubMed ID: 34032165 [TBL] [Abstract][Full Text] [Related]
14. Clinical validation of an ultra high-throughput spiral microfluidics for the detection and enrichment of viable circulating tumor cells. Khoo BL; Warkiani ME; Tan DS; Bhagat AA; Irwin D; Lau DP; Lim AS; Lim KH; Krisna SS; Lim WT; Yap YS; Lee SC; Soo RA; Han J; Lim CT PLoS One; 2014; 9(7):e99409. PubMed ID: 24999991 [TBL] [Abstract][Full Text] [Related]
15. Rapid detection of EGFR mutation in CTCs based on a double spiral microfluidic chip and the real-time RPA method. Li WM; Ren XD; Jiang YZ; Su N; Li BW; Sun XG; Li RX; Lu WP; Deng SL; Li J; Li MX; Huang Q Anal Bioanal Chem; 2023 Jul; 415(17):3535-3547. PubMed ID: 37254002 [TBL] [Abstract][Full Text] [Related]
16. Optimization and Evaluation of a Novel Size Based Circulating Tumor Cell Isolation System. Xu L; Mao X; Imrali A; Syed F; Mutsvangwa K; Berney D; Cathcart P; Hines J; Shamash J; Lu YJ PLoS One; 2015; 10(9):e0138032. PubMed ID: 26397728 [TBL] [Abstract][Full Text] [Related]
17. Detection of CTCs and CSCs in the staging and metastasis of non-small cell lung cancer based on microfluidic chip and the diagnostic significance. Wang SQ; Shuai ZF; Zhang XJ; Wu T; Dong HY; Liu T; Wen QT; Yu XW Eur Rev Med Pharmacol Sci; 2020 Sep; 24(18):9487-9496. PubMed ID: 33015791 [TBL] [Abstract][Full Text] [Related]
19. Wedge-shaped microfluidic chip for circulating tumor cells isolation and its clinical significance in gastric cancer. Yang C; Zhang N; Wang S; Shi D; Zhang C; Liu K; Xiong B J Transl Med; 2018 May; 16(1):139. PubMed ID: 29792200 [TBL] [Abstract][Full Text] [Related]
20. Semi-automatic PD-L1 Characterization and Enumeration of Circulating Tumor Cells from Non-small Cell Lung Cancer Patients by Immunofluorescence. Garcia J; Barthelemy D; Geiguer F; Ballandier J; Li KW; Aurel JP; Le Breton F; Rodriguez-Lafrasse C; Manship B; Couraud S; Payen L J Vis Exp; 2019 Aug; (150):. PubMed ID: 31475991 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]