261 related articles for article (PubMed ID: 29914817)
1. Efficacy and safety of sensor-augmented pump therapy (SAPT) with predictive low-glucose management in patients diagnosed with type 1 diabetes mellitus previously treated with SAPT and low glucose suspend.
Gómez AM; Henao DC; Imitola A; Muñoz OM; Sepúlveda MAR; Kattah L; Guerrero JS; Morros E; Llano JP; Jaramillo MG; León-Vargas F
Endocrinol Diabetes Nutr (Engl Ed); 2018 Oct; 65(8):451-457. PubMed ID: 29914817
[TBL] [Abstract][Full Text] [Related]
2. Impact of sensor-augmented pump therapy with predictive low-glucose management on hypoglycemia and glycemic control in patients with type 1 diabetes mellitus: 1-year follow-up.
Gómez AM; Henao DC; Taboada LB; Leguizamón G; Rondón MA; Muñoz OM; García-Jaramillo MA; León Vargas FM
Diabetes Metab Syndr; 2019; 13(4):2625-2631. PubMed ID: 31405686
[TBL] [Abstract][Full Text] [Related]
3. Reduction in Hypoglycemia With the Predictive Low-Glucose Management System: A Long-term Randomized Controlled Trial in Adolescents With Type 1 Diabetes.
Abraham MB; Nicholas JA; Smith GJ; Fairchild JM; King BR; Ambler GR; Cameron FJ; Davis EA; Jones TW;
Diabetes Care; 2018 Feb; 41(2):303-310. PubMed ID: 29191844
[TBL] [Abstract][Full Text] [Related]
4. Long-Term Efficacy and Safety of Sensor Augmented Insulin Pump Therapy with Low-Glucose Suspend Feature in Patients with Type 1 Diabetes.
Gómez AM; Marín Carrillo LF; Muñoz Velandia OM; Rondón Sepúlveda MA; Arévalo Correa CM; Mora Garzón E; Cuervo Diaz MC; Henao Carrillo DC
Diabetes Technol Ther; 2017 Feb; 19(2):109-114. PubMed ID: 28001445
[TBL] [Abstract][Full Text] [Related]
5. Effectiveness of MiniMed 640G with SmartGuard® System for prevention of hypoglycemia in pediatric patients with type 1 diabetes mellitus.
Villafuerte Quispe B; Martín Frías M; Roldán Martín MB; Yelmo Valverde R; Álvarez Gómez MÁ; Barrio Castellanos R
Endocrinol Diabetes Nutr; 2017 Apr; 64(4):198-203. PubMed ID: 28417874
[TBL] [Abstract][Full Text] [Related]
6. Prevention of Insulin-Induced Hypoglycemia in Type 1 Diabetes with Predictive Low Glucose Management System.
Abraham MB; de Bock M; Paramalingam N; O'Grady MJ; Ly TT; George C; Roy A; Spital G; Karula S; Heels K; Gebert R; Fairchild JM; King BR; Ambler GR; Cameron F; Davis EA; Jones TW
Diabetes Technol Ther; 2016 Jul; 18(7):436-43. PubMed ID: 27148807
[TBL] [Abstract][Full Text] [Related]
7. "Let the Algorithm Do the Work": Reduction of Hypoglycemia Using Sensor-Augmented Pump Therapy with Predictive Insulin Suspension (SmartGuard) in Pediatric Type 1 Diabetes Patients.
Biester T; Kordonouri O; Holder M; Remus K; Kieninger-Baum D; Wadien T; Danne T
Diabetes Technol Ther; 2017 Mar; 19(3):173-182. PubMed ID: 28099035
[TBL] [Abstract][Full Text] [Related]
8. Factors associated with clinically significant hypoglycemia in patients with type 1 diabetes using sensor-augmented pump therapy with predictive low-glucose management: A multicentric study on iberoamerica.
Gómez AM; Imitola A; Henao D; García-Jaramillo M; Giménez M; Viñals C; Grassi B; Torres M; Zuluaga I; Muñoz OM; Rondón M; León-Vargas F; Conget I
Diabetes Metab Syndr; 2021; 15(1):267-272. PubMed ID: 33477103
[TBL] [Abstract][Full Text] [Related]
9. Maternal-Fetal Outcomes in 34 Pregnant Women with Type 1 Diabetes in Sensor-Augmented Insulin Pump Therapy.
Gómez AM; Marín Carrillo LF; Arévalo Correa CM; Muñoz Velandia OM; Rondón Sepúlveda MA; Silva Herrera JL; Henao Carrillo DC
Diabetes Technol Ther; 2017 Jul; 19(7):417-422. PubMed ID: 28731823
[TBL] [Abstract][Full Text] [Related]
10. The PILGRIM study: in silico modeling of a predictive low glucose management system and feasibility in youth with type 1 diabetes during exercise.
Danne T; Tsioli C; Kordonouri O; Blaesig S; Remus K; Roy A; Keenan B; Lee SW; Kaufman FR
Diabetes Technol Ther; 2014 Jun; 16(6):338-47. PubMed ID: 24447074
[TBL] [Abstract][Full Text] [Related]
11. Safety and efficacy of the predictive low glucose management system in the prevention of hypoglycaemia: protocol for randomised controlled home trial to evaluate the Suspend before low function.
Abraham MB; Nicholas JA; Ly TT; Roby HC; Paramalingam N; Fairchild J; King BR; Ambler GR; Cameron F; Davis EA; Jones TW
BMJ Open; 2016 Apr; 6(4):e011589. PubMed ID: 27084290
[TBL] [Abstract][Full Text] [Related]
12. Study of MiniMed 640G Insulin Pump with SmartGuard in Prevention of Low Glucose Events in Adults with Type 1 Diabetes (SMILE): Design of a Hypoglycemia Prevention Trial with Continuous Glucose Monitoring Data as Outcomes.
De Valk HW; Lablanche S; Bosi E; Choudhary P; Silva JD; Castaneda J; Vorrink L; De Portu S; Cohen O
Diabetes Technol Ther; 2018 Nov; 20(11):758-766. PubMed ID: 30325656
[TBL] [Abstract][Full Text] [Related]
13. In-Clinic Evaluation of the MiniMed 670G System "Suspend Before Low" Feature in Children with Type 1 Diabetes.
Wood MA; Shulman DI; Forlenza GP; Bode BW; Pinhas-Hamiel O; Buckingham BA; Kaiserman KB; Liljenquist DR; Bailey TS; Shin J; Huang S; Chen X; Cordero TL; Lee SW; Kaufman FR
Diabetes Technol Ther; 2018 Nov; 20(11):731-737. PubMed ID: 30299976
[TBL] [Abstract][Full Text] [Related]
14. Threshold-based insulin-pump interruption for reduction of hypoglycemia.
Bergenstal RM; Klonoff DC; Garg SK; Bode BW; Meredith M; Slover RH; Ahmann AJ; Welsh JB; Lee SW; Kaufman FR;
N Engl J Med; 2013 Jul; 369(3):224-32. PubMed ID: 23789889
[TBL] [Abstract][Full Text] [Related]
15. The Predictive Low Glucose Management System in Prevention of Clinically Significant Hypoglycemia in Type 1 Diabetes. A Preliminary Study Identifying the Most Common Events Leading Up to Hypoglycemia During Insulin Pump Therapy.
Thomakos P; Mitrakou A; Kepaptsoglou O; Taraoune I; Barreto C; Zoupas CS
Exp Clin Endocrinol Diabetes; 2021 May; 129(5):385-389. PubMed ID: 30986882
[TBL] [Abstract][Full Text] [Related]
16. Efficacy and safety of sensor augmented insulin pump therapy with low-glucose suspend feature in older adults: A retrospective study in Bogota, Colombia.
Morros-González E; Gómez AM; Henao Carrillo DC; Ursida V; Serrano S; Rondón Sepúlveda MA; Muñoz Velandia OM
Diabetes Metab Syndr; 2021; 15(3):649-653. PubMed ID: 33813236
[TBL] [Abstract][Full Text] [Related]
17. Effectiveness of a Predictive Algorithm in the Prevention of Exercise-Induced Hypoglycemia in Type 1 Diabetes.
Abraham MB; Davey R; O'Grady MJ; Ly TT; Paramalingam N; Fournier PA; Roy A; Grosman B; Kurtz N; Fairchild JM; King BR; Ambler GR; Cameron F; Jones TW; Davis EA
Diabetes Technol Ther; 2016 Sep; 18(9):543-50. PubMed ID: 27505305
[TBL] [Abstract][Full Text] [Related]
18. Use of sensor-integrated pump therapy to reduce hypoglycaemia in people with Type 1 diabetes: a real-world study in the UK.
Choudhary P; de Portu S; Arrieta A; Castañeda J; Campbell FM
Diabet Med; 2019 Sep; 36(9):1100-1108. PubMed ID: 31134668
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a Predictive Low-Glucose Management System In-Clinic.
Buckingham BA; Bailey TS; Christiansen M; Garg S; Weinzimer S; Bode B; Anderson SM; Brazg R; Ly TT; Kaufman FR
Diabetes Technol Ther; 2017 May; 19(5):288-292. PubMed ID: 28221823
[TBL] [Abstract][Full Text] [Related]
20. Numerical and clinical precision of continuous glucose monitoring in Colombian patients treated with insulin infusion pump with automated suspension in hypoglycemia.
Gómez AM; Marín Sánchez A; Muñoz OM; Colón Peña CA
Endocrinol Nutr; 2015 Dec; 62(10):485-92. PubMed ID: 26531841
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]