These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

255 related articles for article (PubMed ID: 29916253)

  • 21. Loss-of-function mutations at the rim of the funnel of mechanosensitive channel MscL.
    Yoshimura K; Nomura T; Sokabe M
    Biophys J; 2004 Apr; 86(4):2113-20. PubMed ID: 15041651
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Electromechanical coupling model of gating the large mechanosensitive ion channel (MscL) of Escherichia coli by mechanical force.
    Gu L; Liu W; Martinac B
    Biophys J; 1998 Jun; 74(6):2889-902. PubMed ID: 9635742
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Use of small fluorescent molecules to monitor channel activity.
    Jones SE; Naik RR; Stone MO
    Biochem Biophys Res Commun; 2000 Dec; 279(1):208-12. PubMed ID: 11112440
    [TBL] [Abstract][Full Text] [Related]  

  • 24. A large-conductance mechanosensitive channel in E. coli encoded by mscL alone.
    Sukharev SI; Blount P; Martinac B; Blattner FR; Kung C
    Nature; 1994 Mar; 368(6468):265-8. PubMed ID: 7511799
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Anionic phospholipids affect the rate and extent of flux through the mechanosensitive channel of large conductance MscL.
    Powl AM; East JM; Lee AG
    Biochemistry; 2008 Apr; 47(14):4317-28. PubMed ID: 18341289
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Membrane-protein interactions in mechanosensitive channels.
    Wiggins P; Phillips R
    Biophys J; 2005 Feb; 88(2):880-902. PubMed ID: 15542561
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Temperature-sensitive mutants of MscL mechanosensitive channel.
    Owada N; Yoshida M; Morita K; Yoshimura K
    J Biochem; 2019 Sep; 166(3):281-288. PubMed ID: 31143940
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Visualisation of the mechanosensitive channel of large conductance in bacteria using confocal microscopy.
    Norman C; Liu ZW; Rigby P; Raso A; Petrov Y; Martinac B
    Eur Biophys J; 2005 Jul; 34(5):396-402. PubMed ID: 15812637
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Cross-linking studies and membrane localization and assembly of radiolabelled large mechanosensitive ion channel (MscL) of Escherichia coli.
    Häse CC; Minchin RF; Kloda A; Martinac B
    Biochem Biophys Res Commun; 1997 Mar; 232(3):777-82. PubMed ID: 9126353
    [TBL] [Abstract][Full Text] [Related]  

  • 30. A cytoplasmic helix is required for pentamer formation of the Escherichia coli MscL mechanosensitive channel.
    Ando C; Liu N; Yoshimura K
    J Biochem; 2015 Aug; 158(2):109-14. PubMed ID: 25697390
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Mechanosensitive channels of Escherichia coli: the MscL gene, protein, and activities.
    Sukharev SI; Blount P; Martinac B; Kung C
    Annu Rev Physiol; 1997; 59():633-57. PubMed ID: 9074781
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Activation of bacterial channel MscL in mechanically stimulated droplet interface bilayers.
    Najem JS; Dunlap MD; Rowe ID; Freeman EC; Grant JW; Sukharev S; Leo DJ
    Sci Rep; 2015 Sep; 5():13726. PubMed ID: 26348441
    [TBL] [Abstract][Full Text] [Related]  

  • 33. On the role of individual subunits in MscL gating: "all for one, one for all?".
    Mika JT; Birkner JP; Poolman B; Koçer A
    FASEB J; 2013 Mar; 27(3):882-92. PubMed ID: 23193173
    [TBL] [Abstract][Full Text] [Related]  

  • 34. C-terminal charged cluster of MscL, RKKEE, functions as a pH sensor.
    Kloda A; Ghazi A; Martinac B
    Biophys J; 2006 Mar; 90(6):1992-8. PubMed ID: 16387769
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The mechanosensitive channel of small conductance (MscS) functions as a Jack-in-the box.
    Malcolm HR; Blount P; Maurer JA
    Biochim Biophys Acta; 2015 Jan; 1848(1 Pt A):159-66. PubMed ID: 25450806
    [TBL] [Abstract][Full Text] [Related]  

  • 36. YidC is required for the assembly of the MscL homopentameric pore.
    Pop OI; Soprova Z; Koningstein G; Scheffers DJ; van Ulsen P; Wickström D; de Gier JW; Luirink J
    FEBS J; 2009 Sep; 276(17):4891-9. PubMed ID: 19664056
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Hydrophilicity of a single residue within MscL correlates with increased channel mechanosensitivity.
    Yoshimura K; Batiza A; Schroeder M; Blount P; Kung C
    Biophys J; 1999 Oct; 77(4):1960-72. PubMed ID: 10512816
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Characterizing the mechanosensitive response of Paraburkholderia graminis membranes.
    Miller BL; Dickinson HM; Wingender B; Mikhaylova A; Malcolm HR
    Biochim Biophys Acta Biomembr; 2020 Apr; 1862(4):183176. PubMed ID: 31923411
    [TBL] [Abstract][Full Text] [Related]  

  • 39. The role of the periplasmic loop residue glutamine 65 for MscL mechanosensitivity.
    Tsai IJ; Liu ZW; Rayment J; Norman C; McKinley A; Martinac B
    Eur Biophys J; 2005 Jul; 34(5):403-12. PubMed ID: 15812636
    [TBL] [Abstract][Full Text] [Related]  

  • 40. A hexameric transmembrane pore revealed by two-dimensional crystallization of the large mechanosensitive ion channel (MscL) of Escherichia coli.
    Saint N; Lacapère JJ; Gu LQ; Ghazi A; Martinac B; Rigaud JL
    J Biol Chem; 1998 Jun; 273(24):14667-70. PubMed ID: 9614061
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.