These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 29916260)

  • 1. Platelet Aggregation in Healthy Participants is Not Affected by Smoking, Drinking Coffee, Consuming a High-Fat Meal, or Performing Physical Exercise.
    Krekels JPM; Verhezen PWM; Henskens YMC
    Clin Appl Thromb Hemost; 2019; 25():1076029618782445. PubMed ID: 29916260
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of aspirin response by Multiplate whole blood aggregometry and light transmission aggregometry.
    Pedersen SB; Grove EL; Nielsen HL; Mortensen J; Kristensen SD; Hvas AM
    Platelets; 2009 Sep; 20(6):415-20. PubMed ID: 19658002
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The risk of false results in the assessment of platelet function in the absence of antiplatelet medication: comparison of the PFA-100, multiplate electrical impedance aggregometry and verify now assays.
    Can MM; Tanboğa IH; Türkyilmaz E; Karabay CY; Akgun T; Koca F; Tokgoz HC; Keles N; Ozkan A; Bezgin T; Ozveren O; Sonmez K; Sağlam M; Ozdemir N; Kaymaz C
    Thromb Res; 2010 Apr; 125(4):e132-7. PubMed ID: 19954823
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Assessment of ADP-induced platelet aggregation with light transmission aggregometry and multiple electrode platelet aggregometry before and after clopidogrel treatment.
    Sibbing D; Braun S; Jawansky S; Vogt W; Mehilli J; Schömig A; Kastrati A; von Beckerath N
    Thromb Haemost; 2008 Jan; 99(1):121-6. PubMed ID: 18217143
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of light transmission aggregometry and multiple electrode aggregometry for the evaluation of patients with mucocutaneous bleeding.
    Sun P; McMillan-Ward E; Mian R; Israels SJ
    Int J Lab Hematol; 2019 Feb; 41(1):133-140. PubMed ID: 30358923
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Rapid evaluation of platelet function using the Multiplate® Analyzer.
    Würtz M; Hvas AM; Christensen KH; Rubak P; Kristensen SD; Grove EL
    Platelets; 2014; 25(8):628-33. PubMed ID: 24246241
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Variables influencing Multiplate(TM) whole blood impedance platelet aggregometry and turbidimetric platelet aggregation in healthy individuals.
    Seyfert UT; Haubelt H; Vogt A; Hellstern P
    Platelets; 2007 May; 18(3):199-206. PubMed ID: 17497431
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnosis of Glanzmann thrombasthenia by whole blood impedance analyzer (MEA) vs. light transmission aggregometry.
    Albanyan A; Al-Musa A; AlNounou R; Al Zahrani H; Nasr R; AlJefri A; Saleh M; Malik A; Masmali H; Owaidah T
    Int J Lab Hematol; 2015 Aug; 37(4):503-8. PubMed ID: 25537026
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy.
    Enko D; Mangge H; Münch A; Niedrist T; Mahla E; Metzler H; Prüller F
    Biochem Med (Zagreb); 2017 Feb; 27(1):217-224. PubMed ID: 28392742
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An assessment of cardiopulmonary bypass-induced changes in platelet function using whole blood and classical light transmission aggregometry: the results of a pilot study.
    Velik-Salchner C; Maier S; Innerhofer P; Kolbitsch C; Streif W; Mittermayr M; Praxmarer M; Fries D
    Anesth Analg; 2009 Jun; 108(6):1747-54. PubMed ID: 19448196
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of platelet function on whole blood by multiple electrode aggregometry in high-risk patients with coronary artery disease receiving antiplatelet therapy.
    Paniccia R; Antonucci E; Maggini N; Romano E; Gori AM; Marcucci R; Prisco D; Abbate R
    Am J Clin Pathol; 2009 Jun; 131(6):834-42. PubMed ID: 19461090
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Platelet function in baboons and humans - A comparative study of whole blood using impedance platelet aggregometry (Multiplate®).
    Ponschab M; van Griensven M; Heitmeier S; Laux V; Schlimp CJ; Calatzis A; Bahrami S; Redl H; Schöchl H
    Thromb Res; 2016 Nov; 147():115-121. PubMed ID: 27736703
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Platelet Function Analyzed by Light Transmission Aggregometry.
    Hvas AM; Favaloro EJ
    Methods Mol Biol; 2017; 1646():321-331. PubMed ID: 28804839
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparison between a new platelet count drop method PL-11, light transmission aggregometry, VerifyNow aspirin system and thromboelastography for monitoring short-term aspirin effects in healthy individuals.
    Guan J; Cong Y; Ren J; Zhu Y; Li L; Deng X; Bai J
    Platelets; 2015; 26(1):25-30. PubMed ID: 24433273
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Assessment of platelet function on the routine coagulation analyzer Sysmex CS-2000i.
    Frère C; Kobayashi K; Dunois C; Amiral J; Morange PE; Alessi MC
    Platelets; 2018 Jan; 29(1):95-97. PubMed ID: 28960123
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Centrifugation speed affects light transmission aggregometry.
    Merolla M; Nardi MA; Berger JS
    Int J Lab Hematol; 2012 Feb; 34(1):81-5. PubMed ID: 21794095
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Precision and reliability of 5 platelet function tests in healthy volunteers and donors on daily antiplatelet agent therapy.
    Karon BS; Tolan NV; Koch CD; Wockenfus AM; Miller RS; Lingineni RK; Pruthi RK; Chen D; Jaffe AS
    Clin Chem; 2014 Dec; 60(12):1524-31. PubMed ID: 25281703
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of an automated light transmission aggregometry.
    Ling LQ; Liao J; Niu Q; Wang X; Jia J; Zuo CH; Jiang H; Zhou J
    Platelets; 2017 Nov; 28(7):712-719. PubMed ID: 28150526
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Platelet Aggregation Testing on a Routine Coagulation Analyzer: A Method Comparison Study.
    Stratmann J; Karmal L; Zwinge B; Miesbach W
    Clin Appl Thromb Hemost; 2019; 25():1076029619885184. PubMed ID: 31773967
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of four methods to assess high-on platelet reactivity under P2Y12 receptor inhibitor.
    Mingant F; Didier R; Gilard M; Martin F; Nicol PP; Ugo V; Lippert E; Galinat H
    Platelets; 2018 May; 29(3):257-264. PubMed ID: 29580115
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.