BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

359 related articles for article (PubMed ID: 29916933)

  • 1. A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
    Nienhaus M; Zderic I; Wahl D; Gueorguiev B; Rommens PM
    J Bone Joint Surg Am; 2018 Jun; 100(12):e83. PubMed ID: 29916933
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
    Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
    Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Lateral rim variable angle locked plating versus tension band wiring of simple and complex patella fractures: a biomechanical study.
    Warner S; Sommer C; Zderic I; Woodburn W; Castle R; Penman J; Saura-Sanchez E; Helfet DL; Gueorguiev B; Stoffel K
    Arch Orthop Trauma Surg; 2024 May; 144(5):2131-2140. PubMed ID: 38520547
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Anterior variable-angle locked plating versus tension band wiring of simple and complex patella fractures - a biomechanical investigation.
    Stoffel K; Zderic I; Pastor T; Woodburn W; Castle R; Penman J; Saura-Sanchez E; Gueorguiev B; Sommer C
    BMC Musculoskelet Disord; 2023 Apr; 24(1):279. PubMed ID: 37041618
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of a 3.5 mm anterior locking plate to cannulated screws with anterior tension band wiring in comminuted patellar fractures.
    Wagner FC; Neumann MV; Wolf S; Jonaszik A; Izadpanah K; Piatek S; Südkamp NP
    Injury; 2020 Jun; 51(6):1281-1287. PubMed ID: 32197829
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transverse patella fracture fixation: A cadaveric biomechanical comparison of cannulated screws and anterior tension band versus low-profile, multiplanar mesh plating.
    Garner MR; Homcha B; Cowman T; Goss M; Reid JS; Lewis GS
    Injury; 2024 Jun; 55(6):111574. PubMed ID: 38669892
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Open reduction and internal fixation of patellar fractures with tension band wiring through cannulated screws.
    Malik M; Halwai MA
    J Knee Surg; 2014 Oct; 27(5):377-82. PubMed ID: 24414389
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Novel techniques demonstrate superior fixation of simple transverse patella fractures - A biomechanical study.
    Lenihan J; Ramos-Pascual S; Silvestros P; Beak P; Miles AW; Trompeter A
    Injury; 2020 Jun; 51(6):1288-1293. PubMed ID: 32276726
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A Biomechanical Study of an Alternative Internal Fixation Method for Transverse Patella Fractures.
    Han S; Li D; Zhang P; Yin X; Kou Y; Han N; Fu Z
    Orthopedics; 2018 Sep; 41(5):e643-e648. PubMed ID: 30011055
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical comparison of a novel tensioned cable construct versus tension band wiring for transverse patella fracture fixation.
    Kagan BD; Sundet AD; Gardner-Morse M; Chaidarun PL; Beynnon BD; Schottel PC
    Eur J Orthop Surg Traumatol; 2023 Jul; 33(5):1573-1580. PubMed ID: 35759107
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A novel technique for treating simple transverse patellar fractures using cannulated screws: a cadaveric and clinical study.
    Han F; Zhong Z; Zhou M; Chen Q; Liu Y; Rui Y; Li F
    J Orthop Surg Res; 2023 Nov; 18(1):835. PubMed ID: 37926844
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A double button adjustable loop device is biomechanically equivalent to tension band wire in the fixation of transverse patellar fractures-A cadaveric study.
    Han F; Pearce CJ; Ng DQ; Ramruttun AK; Chong DY; Murphy D; Lim CT; Lee BC
    Injury; 2017 Feb; 48(2):270-276. PubMed ID: 27890337
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical evaluation of current patella fracture fixation techniques.
    Carpenter JE; Kasman RA; Patel N; Lee ML; Goldstein SA
    J Orthop Trauma; 1997 Jul; 11(5):351-6. PubMed ID: 9294799
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Factors affecting the outcomes of modified tension band wiring techniques in transverse patellar fractures.
    Hsu KL; Chang WL; Yang CY; Yeh ML; Chang CW
    Injury; 2017 Dec; 48(12):2800-2806. PubMed ID: 29037518
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of cannulated screw with tension band wiring versus compressive cannulated locking bolt and nut device (CompresSURE) in patella fractures-a cadaveric biomechanical study.
    Domby B; Henderson E; Nayak A; Erdoğan M; Gutierrez S; Santoni BG; Sagi HC
    J Orthop Trauma; 2012 Dec; 26(12):678-83. PubMed ID: 22932750
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cannulated Screw Prominence in Tension Band Wiring of Patella Fractures Increases Fracture Gapping: A Cadaver Study.
    Avery MC; Jo S; Chang A; Ricci WM; McAndrew C; Miller AN; Tang S
    Clin Orthop Relat Res; 2019 May; 477(5):1249-1255. PubMed ID: 30998643
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical comparison of three tension band wiring techniques for transverse fracture of patella: Kirschner wires, cannulated screws, and ring pins.
    Lee KH; Lee Y; Lee YH; Cho BW; Kim MB; Baek GH
    J Orthop Surg (Hong Kong); 2019; 27(3):2309499019882140. PubMed ID: 31711358
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical Comparison of Tension Band Fixation of Patella Transverse Fracture: Headless Screws Versus Headed Screws.
    Martin JM; Applin DT; McGrady LM; Wang M; Schmeling GJ
    J Orthop Trauma; 2019 Jun; 33(6):e240-e245. PubMed ID: 30720558
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Arthroscopically assisted percutaneous osteosynthesis of displaced transverse patellar fractures with figure-eight wiring through paired cannulated screws.
    Chiang CC; Huang CK; Chen WM; Lin CF; Tzeng YH; Liu CL
    Arch Orthop Trauma Surg; 2011 Jul; 131(7):949-54. PubMed ID: 21188394
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.