BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

283 related articles for article (PubMed ID: 29921222)

  • 1. Is intra-bladder pressure measurement a reliable indicator for raised intra-abdominal pressure? A prospective comparative study.
    Al-Abassi AA; Al Saadi AS; Ahmed F
    BMC Anesthesiol; 2018 Jun; 18(1):69. PubMed ID: 29921222
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The evaluation of the effect of body positioning on intra-abdominal pressure measurement and the effect of intra-abdominal pressure at different body positioning on organ function and prognosis in critically ill patients.
    Yi M; Leng Y; Bai Y; Yao G; Zhu X
    J Crit Care; 2012 Apr; 27(2):222.e1-6. PubMed ID: 22033056
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Utility of monitoring intra-abdominal pressure in critically ill children].
    González L; Rodríguez R; Mencía S; Gil-Ruiz M; Sanavia E; López Herce J
    An Pediatr (Barc); 2012 Oct; 77(4):254-60. PubMed ID: 22455949
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Increases in intra-abdominal pressure affect pulmonary compliance.
    Obeid F; Saba A; Fath J; Guslits B; Chung R; Sorensen V; Buck J; Horst M
    Arch Surg; 1995 May; 130(5):544-7; discussion 547-8. PubMed ID: 7748095
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intra-abdominal pressure measurement method via the urinary-tube: bedside validation of a biomechanical model integrating urine column height and bladder urinary volume.
    Vallee F; Dupas C; Feuvrier V; Mebazaa A; Ferre F; Mari A; Genestal M; Fourcade O
    Ann Surg; 2010 Jan; 251(1):127-32. PubMed ID: 19864939
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Can femoral venous pressure be used as an estimate for standard vesical intra-abdominal pressure measurement?
    Howard AE; Regli A; Litton E; Malbrain MM; Palermo AM; De Keulenaer BL
    Anaesth Intensive Care; 2016 Nov; 44(6):704-711. PubMed ID: 27832556
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Noninvasive assessment of intra-abdominal pressure by measurement of abdominal wall tension.
    van Ramshorst GH; Salih M; Hop WC; van Waes OJ; Kleinrensink GJ; Goossens RH; Lange JF
    J Surg Res; 2011 Nov; 171(1):240-4. PubMed ID: 20462598
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In Vitro Validation of a Novel Continuous Intra-Abdominal Pressure Measurement System (TraumaGuard).
    Tayebi S; Wise R; Zarghami A; Malbrain L; Khanna AK; Dabrowski W; Stiens J; Malbrain MLNG
    J Clin Med; 2023 Sep; 12(19):. PubMed ID: 37834904
    [No Abstract]   [Full Text] [Related]  

  • 9. [New device and technique to measure intra-abdominal pressure].
    Castañón-González JA; Satué-Rodríguez J; Carrillo Rosales F; Polanco-González C; Miranda-Ruíz R; Camacho-Juárez S
    Cir Cir; 2013; 81(2):112-7. PubMed ID: 23522311
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does femoral venous pressure measurement correlate well with intrabladder pressure measurement? A multicenter observational trial.
    De Keulenaer BL; Regli A; Dabrowski W; Kaloiani V; Bodnar Z; Cea JI; Litvin AA; Davis WA; Palermo AM; De Waele JJ; Malbrain ML
    Intensive Care Med; 2011 Oct; 37(10):1620-7. PubMed ID: 21739341
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Feasibility analysis of a novel non-invasive ultrasonographic method for the measurement of intra-abdominal pressure in the intensive care unit.
    See KC; Tayebi S; Sum CL; Phua J; Stiens J; Wise R; Mukhopadhyay A; Malbrain MLNG
    J Clin Monit Comput; 2023 Oct; 37(5):1351-1359. PubMed ID: 37133628
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Evaluation of transvesical intra-abdominal pressure measurement in hospitalized dogs.
    Fetner M; Prittie J
    J Vet Emerg Crit Care (San Antonio); 2012 Apr; 22(2):230-8. PubMed ID: 22487320
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intra-abdominal hypertension in the critically ill: interrater reliability of bladder pressure measurement.
    Katsios C; Ye C; Hoad N; Piraino T; Soth M; Cook D
    J Crit Care; 2013 Oct; 28(5):886.e1-6. PubMed ID: 23726386
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Reliability of intra-abdominal pressure measurements using the modified Kron technique.
    Hunt L; Frost SA; Alexandrou E; Hillman K; Newton PJ; Davidson PM
    Acta Clin Belg; 2015 Apr; 70(2):116-20. PubMed ID: 25287555
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparison of fluid instillation volumes to assess intra-abdominal pressure using Kron's methods.
    Hunt L; Van Luenen H; Alexandrou E; Frost SA; Davidson PM; Hillman K; D'Amours S
    J Trauma Acute Care Surg; 2012 Jul; 73(1):152-5. PubMed ID: 22710774
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Effects of different reference point on intra-abdominal pressure measurement in critically ill patients: a clinical trial].
    Liu T; Liu SQ; Liu L; Yang CS; Yang -; Qiu HB
    Zhonghua Wai Ke Za Zhi; 2011 Jan; 49(1):49-52. PubMed ID: 21418838
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of intra-abdominal pressure in large incisional hernia repair to prevent abdominal compartmental syndrome.
    Angelici AM; Perotti B; Dezzi C; Amatucci C; Mancuso G; Caronna R; Palumbo P
    G Chir; 2016; 37(1):31-6. PubMed ID: 27142823
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Harrahill's technique: a simple screening test for intra-abdominal pressure measurement.
    Otto J; Binnebösel M; Junge K; Jansen M; Dembinski R; Schumpelick V; Schachtrupp A
    Hernia; 2010 Aug; 14(4):415-9. PubMed ID: 20490586
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Intestinal fatty acid binding protein as a marker for intra-abdominal pressure-related complications in patients admitted to the intensive care unit; study protocol for a prospective cohort study (I-Fabulous study).
    Strang SG; Van Waes OJ; Van der Hoven B; Ali S; Verhofstad MH; Pickkers P; Van Lieshout EM
    Scand J Trauma Resusc Emerg Med; 2015 Jan; 23():6. PubMed ID: 25591785
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Comparison of direct and indirect methods of intra-abdominal pressure measurement in normal horses.
    Munsterman AS; Hanson RR
    J Vet Emerg Crit Care (San Antonio); 2009 Dec; 19(6):545-53. PubMed ID: 20017760
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.