BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

402 related articles for article (PubMed ID: 29936634)

  • 1. Atrioventricular and intraventricular block after transcatheter aortic valve implantation.
    Lee JJ; Goldschlager N; Mahadevan VS
    J Interv Card Electrophysiol; 2018 Aug; 52(3):315-322. PubMed ID: 29936634
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Predictors of right ventricular pacing and pacemaker dependence in transcatheter aortic valve replacement patients.
    Sharma E; Chu AF
    J Interv Card Electrophysiol; 2018 Jan; 51(1):77-86. PubMed ID: 29260369
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Conduction Abnormalities and Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement Using the Repositionable LOTUS Device: The United Kingdom Experience.
    Rampat R; Khawaja MZ; Hilling-Smith R; Byrne J; MacCarthy P; Blackman DJ; Krishnamurthy A; Gunarathne A; Kovac J; Banning A; Kharbanda R; Firoozi S; Brecker S; Redwood S; Bapat V; Mullen M; Aggarwal S; Manoharan G; Spence MS; Khogali S; Dooley M; Cockburn J; de Belder A; Trivedi U; Hildick-Smith D
    JACC Cardiovasc Interv; 2017 Jun; 10(12):1247-1253. PubMed ID: 28641846
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Predictors for new-onset conduction block in patients with pure native aortic regurgitation after transcatheter aortic valve replacement with a new-generation self-expanding valve (VitaFlow Liberty
    Zhang X; Liang C; Zha L; Zuo Q; Hu G; Ding J; Tang S
    BMC Cardiovasc Disord; 2024 Jan; 24(1):77. PubMed ID: 38281925
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Conduction disturbance after isolated surgical aortic valve replacement in degenerative aortic stenosis.
    Hwang YM; Kim J; Lee JH; Kim M; Hwang J; Kim JB; Jung SH; Choo SJ; Nam GB; Choi KJ; Chung CH; Lee JW; Kim YH
    J Thorac Cardiovasc Surg; 2017 Nov; 154(5):1556-1565.e1. PubMed ID: 28712585
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Permanent Pacemaker Implantation After Rapid Deployment Aortic Valve Replacement.
    Romano MA; Koeckert M; Mumtaz MA; Slachman FN; Patel HJ; Chitwood WR; Barnhart GR; Grossi EA;
    Ann Thorac Surg; 2018 Sep; 106(3):685-690. PubMed ID: 29705366
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Utility of 30-Day Continuous Ambulatory Monitoring to Identify Patients With Delayed Occurrence of Atrioventricular Block After Transcatheter Aortic Valve Replacement.
    Tian Y; Padmanabhan D; McLeod CJ; Zhang P; Xiao P; Sandhu GS; Greason KL; Gulati R; Nkomo VT; Rihal CS; Polk LE; Sanvick C; Liu XP; Friedman PA; Cha YM
    Circ Cardiovasc Interv; 2019 Dec; 12(12):e007635. PubMed ID: 31833417
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ratio of left ventricular outflow tract area to aortic annulus area and complete atrioventricular block after transcatheter aortic valve replacement for aortic stenosis.
    Kikuchi S; Minamimoto Y; Matsushita K; Cho T; Terasaka K; Hanajima Y; Nakahashi H; Gohbara M; Kimura Y; Yasuda S; Okada K; Matsuzawa Y; Iwahashi N; Kosuge M; Ebina T; Morel O; Ohlmann P; Uchida K; Hibi K
    Int J Cardiol; 2024 Feb; 397():131608. PubMed ID: 38030042
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of New-Onset Right Bundle-Branch Block After Transcatheter Aortic Valve Replacement on Permanent Pacemaker Implantation.
    Kikuchi S; Minamimoto Y; Matsushita K; Cho T; Terasaka K; Hanajima Y; Nakahashi H; Gohbara M; Kimura Y; Yasuda S; Okada K; Matsuzawa Y; Iwahashi N; Kosuge M; Ebina T; Morel O; Ohlmann P; Uchida K; Hibi K
    J Am Heart Assoc; 2024 May; 13(9):e032777. PubMed ID: 38639357
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Is electrophysiological study a novel predictor for permanent pacemaker implantation after transcatheter aortic valve implantation?
    Çetinkaya Z; Elçik D; Keleşoğlu Ş; Cesur B; Yaşan M; Karabiyik U; Bingöl B; Kalay N; Topsakal R; Tunçay A; Doğan A; Inanç MT
    Turk J Med Sci; 2023; 53(6):1799-1806. PubMed ID: 38813482
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Frequency of conduction disturbances after Edwards SAPIEN percutaneous valve implantation.
    Laynez A; Ben-Dor I; Barbash IM; Hauville C; Sardi G; Maluenda G; Xue Z; Satler LF; Pichard AD; Lindsay J; Waksman R
    Am J Cardiol; 2012 Oct; 110(8):1164-8. PubMed ID: 22770935
    [TBL] [Abstract][Full Text] [Related]  

  • 12. High-degree atrioventricular block in patients with preexisting bundle branch block or bundle branch block occurring during transcatheter aortic valve implantation.
    Egger F; Nürnberg M; Rohla M; Weiss TW; Unger G; Smetana P; Geppert A; Gruber SC; Bambazek A; Falkensammer J; Waldenberger FR; Huber K; Freynhofer MK
    Heart Rhythm; 2014 Dec; 11(12):2176-82. PubMed ID: 25034184
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factors for atrioventricular block after transcatheter aortic valve implantation: a single-centre analysis including assessment of aortic calcifications and follow-up.
    Pollari F; Großmann I; Vogt F; Kalisnik JM; Cuomo M; Schwab J; Fischlein T; Pfeiffer S
    Europace; 2019 May; 21(5):787-795. PubMed ID: 30629159
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Low permanent pacemaker rates following Lotus device implantation for transcatheter aortic valve replacement due to modified implantation protocol.
    Krackhardt F; Kherad B; Krisper M; Pieske B; Laule M; Tschöpe C
    Cardiol J; 2017; 24(3):250-258. PubMed ID: 28248410
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A single-centre cohort and short-term follow-up of patients who developed persistent new onset left bundle branch block after transcatheter aortic valve replacement.
    Akdemir B; Roukoz H
    Acta Cardiol; 2020 Aug; 75(4):360-365. PubMed ID: 31984845
    [No Abstract]   [Full Text] [Related]  

  • 16. Intraprocedural high-degree atrioventricular block or complete heart block in transcatheter aortic valve replacement recipients with no prior intraventricular conduction disturbances.
    Junquera L; Freitas-Ferraz AB; Padrón R; Silva I; Nunes Ferreira-Neto A; Guimaraes L; Mohammadi S; Morís C; Philippon F; Rodés-Cabau J
    Catheter Cardiovasc Interv; 2020 Apr; 95(5):982-990. PubMed ID: 31037836
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Permanent pacing after transcatheter aortic valve implantation of a CoreValve prosthesis as determined by electrocardiographic and electrophysiological predictors: a single-centre experience.
    Kostopoulou A; Karyofillis P; Livanis E; Thomopoulou S; Stefopoulos C; Doudoumis K; Theodorakis G; Voudris V
    Europace; 2016 Jan; 18(1):131-7. PubMed ID: 26060209
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pacemaker implantation and need for ventricular pacing during follow-up after transcatheter aortic valve implantation.
    Calvi V; Pruiti GP
    Pacing Clin Electrophysiol; 2014 Dec; 37(12):1589-91. PubMed ID: 25319956
    [No Abstract]   [Full Text] [Related]  

  • 19. Pacemaker implantation and need for ventricular pacing during follow-up after transcatheter aortic valve implantation.
    Ramazzina C; Knecht S; Jeger R; Kaiser C; Schaer B; Osswald S; Sticherling C; Kühne M
    Pacing Clin Electrophysiol; 2014 Dec; 37(12):1592-601. PubMed ID: 25223835
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Need for pacemaker implantation in patients with normal QRS duration immediately after transcatheter aortic valve implantation.
    Schoechlin S; Jalil F; Blum T; Ruile P; Hein M; Nührenberg TG; Arentz T; Neumann FJ
    Europace; 2019 Dec; 21(12):1851-1856. PubMed ID: 31578544
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.