These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

108 related articles for article (PubMed ID: 29945312)

  • 1. Interchangeability of Procalcitonin Measurements Using the Point of Care Testing i-CHROMATM Reader and the Automated Liaison XL.
    Stenner E; Barbati G; West N; Ben FD; Martin F; Ruscio M
    Clin Lab; 2018 Jun; 64(6):1097-1100. PubMed ID: 29945312
    [TBL] [Abstract][Full Text] [Related]  

  • 2. As a Novel Procalcitonin Assay is Architect B∙R∙A∙H∙M∙S PCT; Comparison of Two Commercial Systems.
    Aydemir Ö; Karakeçe E; Köroğlu M; Aydemir Y; Terzi HA; Erkorkmaz Ü; Altindiş M
    Clin Lab; 2019 Apr; 65(4):. PubMed ID: 30969065
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Procalcitonin Assays on KRYPTOR and LIAISON
    Dipalo M; Gnocchi C; Avanzini P; Musa R; Di Pietro M; Aloe R
    Diagnostics (Basel); 2019 Aug; 9(3):. PubMed ID: 31398868
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison and Agreement Analysis of ARCHITECT i2000SR and i-CHROMATM Reader for Detecting Human Chorionic Gonadotropin Beta Subunit in Plasma.
    Ma M; Zhu M; Zhuo B; Wang X; Wu Z; Xu L
    Clin Lab; 2019 Sep; 65(9):. PubMed ID: 31532105
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of the Siemens Atellica BRAHMS and the Abbott Architect BRAHMS Procalcitonin Assays.
    Walker C; Shuster A; Weber C; Gebhardt K; Scheidegger M; Swartzwelder J; Williams J; Li J
    Ann Clin Lab Sci; 2021 Mar; 51(2):241-244. PubMed ID: 33941564
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Development of a novel chemiluminescence immunoassay for the detection of procalcitonin.
    Wang G; Wan Y; Lin G; Li Z; Dong Z; Liu T
    J Immunol Methods; 2020; 484-485():112829. PubMed ID: 32673618
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Clinical performance of the novel DiaSorin LIAISON(®) XL murex: HBsAg Quant, HCV-Ab, HIV-Ab/Ag assays.
    Krawczyk A; Hintze C; Ackermann J; Goitowski B; Trippler M; Grüner N; Neumann-Fraune M; Verheyen J; Fiedler M
    J Clin Virol; 2014 Jan; 59(1):44-9. PubMed ID: 24268764
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Two-center comparison of 10 fully-automated commercial procalcitonin (PCT) immunoassays.
    Lippi G; Salvagno GL; Gelati M; Pucci M; Lo Cascio C; Demonte D; Faggian D; Plebani M
    Clin Chem Lab Med; 2019 Dec; 58(1):77-84. PubMed ID: 31539351
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Quantification of hepatitis B surface antigen with the novel DiaSorin LIAISON XL Murex HBsAg Quant: correlation with the ARCHITECT quantitative assays.
    Burdino E; Ruggiero T; Proietti A; Milia MG; Olivero A; Caviglia GP; Marietti M; Rizzetto M; Smedile A; Ghisetti V
    J Clin Virol; 2014 Aug; 60(4):341-6. PubMed ID: 24930708
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term stability of procalcitonin in frozen samples and comparison of Kryptor and VIDAS automated immunoassays.
    Schuetz P; Christ-Crain M; Huber AR; Müller B
    Clin Biochem; 2010 Feb; 43(3):341-4. PubMed ID: 19747473
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of a fully automated procalcitonin chemiluminescence immunoassay.
    Hubl W; Krassler J; Zingler C; Pertschy A; Hentschel J; Gerhards-Reich C; Mack M; Demant T
    Clin Lab; 2003; 49(7-8):319-27. PubMed ID: 12908732
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quality planning and control strategy for AQT90 flex Radiometer
    Ilardo C; Reynaud C; Bonneton R; Barthes J
    Scand J Clin Lab Invest; 2020 Sep; 80(5):427-432. PubMed ID: 32478619
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Serum 25-hydroxyvitamin D measurement: Comparative evaluation of three automated immunoassays.
    Trimboli F; Rotundo S; Armili S; Mimmi S; Lucia F; Montenegro N; Antico GC; Cerra A; Gaetano M; Galato F; Giaquinto Carinci L; Iania D; Mancuso S; Martucci M; Teti C; Greco M; Cuda G; Angotti E
    Pract Lab Med; 2021 Aug; 26():e00251. PubMed ID: 34386568
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Assay-specific decision limits for two new automated parathyroid hormone and 25-hydroxyvitamin D assays.
    Souberbielle JC; Fayol V; Sault C; Lawson-Body E; Kahan A; Cormier C
    Clin Chem; 2005 Feb; 51(2):395-400. PubMed ID: 15563480
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Performance analysis of newly developed point-of-care hemoglobinometer (TrueHb) against an automated hematology analyzer (Sysmex XT 1800i) in terms of precision in hemoglobin measurement.
    Srivastava A; Koul V; Dwivedi SN; Upadhyaya AD; Ahuja A; Saxena R
    Int J Lab Hematol; 2015 Aug; 37(4):483-5. PubMed ID: 25418886
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Quantum Dots-Based Point-of-Care Measurement of Procalcitonin in Finger-Prick Blood and Venous Whole Blood Specimens.
    Tang J; Jiang Y; Ge Z; Wu H; Chen H; Dai J; Gu Y; Mao X; Lu J
    Lab Med; 2020 Jan; 51(1):34-40. PubMed ID: 31245815
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Heparin Reversal After Cardiopulmonary Bypass: Are Point-of-Care Coagulation Tests Interchangeable?
    Willems A; Savan V; Faraoni D; De Ville A; Rozen L; Demulder A; Van der Linden P
    J Cardiothorac Vasc Anesth; 2016 Oct; 30(5):1184-9. PubMed ID: 27461795
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of the performance of a new automated HIV combination assay.
    Ghisetti V; Coignard C; Allice T; Thoai Duong L
    J Clin Virol; 2017 Nov; 96():80-83. PubMed ID: 29020658
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The "Petechiae in children" (PiC) study: evaluating potential clinical decision rules for the management of feverish children with non-blanching rashes, including the role of point of care testing for Procalcitonin & Neisseria meningitidis DNA - a study protocol.
    Waterfield T; Lyttle MD; Fairley D; Mckenna J; Woolfall K; Lynn F; Maney JA; Roland D; Weir A; Shields MD;
    BMC Pediatr; 2018 Jul; 18(1):246. PubMed ID: 30060751
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the Comparability of Wantai Wan200+ Instrument with Routine Laboratory Assays for 21 Different Analytes.
    Talli I; Padoan A; Cosma C; Furlan G; Zaninotto M; Marchioro L; Galozzi P; Basso D; Plebani M
    J Clin Med; 2024 Apr; 13(8):. PubMed ID: 38673517
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 6.