These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

684 related articles for article (PubMed ID: 29954202)

  • 1. Highly crosslinked polyethylene wear rates and acetabular component orientation: a minimum ten-year follow-up.
    Teeter MG; Lanting BA; Naudie DD; McCalden RW; Howard JL; MacDonald SJ
    Bone Joint J; 2018 Jul; 100-B(7):891-897. PubMed ID: 29954202
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Results of a randomized controlled trial with five-year radiostereometric analysis results of vitamin E-infused highly crosslinked versus moderately crosslinked polyethylene in reverse total hip arthroplasty.
    Thoen PS; Nordsletten L; Pripp AH; Röhrl SM
    Bone Joint J; 2020 Dec; 102-B(12):1646-1653. PubMed ID: 33249906
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Change in Acetabular Cup Orientation From Supine to Standing Position and Its Effect on Wear of Highly Crosslinked Polyethylene.
    Teeter MG; Goyal P; Yuan X; Howard JL; Lanting BA
    J Arthroplasty; 2018 Jan; 33(1):263-267. PubMed ID: 28917617
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The Safe Zone Range for Cup Anteversion Is Narrower Than for Inclination in THA.
    Murphy WS; Yun HH; Hayden B; Kowal JH; Murphy SB
    Clin Orthop Relat Res; 2018 Feb; 476(2):325-335. PubMed ID: 29529664
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Effect of Acetabular Position on Polyethylene Liner Wear Measured Using Simultaneous Biplanar Acquisition.
    Goyal P; Howard JL; Yuan X; Teeter MG; Lanting BA
    J Arthroplasty; 2017 May; 32(5):1670-1674. PubMed ID: 28087161
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Revision Total Hip Arthroplasty with Retained Acetabular Component.
    Adelani MA; Mall NA; Nyazee H; Clohisy JC; Barrack RL; Nunley RM
    J Bone Joint Surg Am; 2014 Jun; 96(12):1015-1020. PubMed ID: 24951737
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.
    Garvin KL; White TC; Dusad A; Hartman CW; Martell J
    Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of vitamin E-diffused highly crosslinked polyethylene wear and porous titanium-coated shell stability: a seven-year randomized control trial using radiostereometric analysis.
    Galea VP; Rojanasopondist P; Laursen M; Muratoglu OK; Malchau H; Bragdon C
    Bone Joint J; 2019 Jul; 101-B(7):760-767. PubMed ID: 31256674
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Relationship Between Polyethylene Wear and Periprosthetic Osteolysis in Total Hip Arthroplasty at 12 Years in a Randomized Controlled Trial Cohort.
    Broomfield JA; Malak TT; Thomas GE; Palmer AJ; Taylor A; Glyn-Jones S
    J Arthroplasty; 2017 Apr; 32(4):1186-1191. PubMed ID: 27998657
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correlation of Cup Inclination Angle with Liner Wear for Metal-on-polyethylene in Hip Primary Arthroplasty.
    Tian JL; Sun L; Hu RY; Han W; Tian XB
    Orthop Surg; 2017 May; 9(2):186-190. PubMed ID: 28557297
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Femoral-Acetabular Mating: The Effect of Femoral and Combined Anteversion on Cross-Linked Polyethylene Wear.
    Mayeda BF; Haw JG; Battenberg AK; Schmalzried TP
    J Arthroplasty; 2018 Oct; 33(10):3320-3324. PubMed ID: 29970327
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of native anatomy with recommended safe component orientation in total hip arthroplasty for primary osteoarthritis.
    Merle C; Grammatopoulos G; Waldstein W; Pegg E; Pandit H; Aldinger PR; Gill HS; Murray DW
    J Bone Joint Surg Am; 2013 Nov; 95(22):e172. PubMed ID: 24257672
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Fifteen-Year Results of Total Hip Arthroplasty With Cobalt-Chromium Femoral Heads on Highly Cross-Linked Polyethylene in Patients 50 Years and Less.
    Rames RD; Stambough JB; Pashos GE; Maloney WJ; Martell JM; Clohisy JC
    J Arthroplasty; 2019 Jun; 34(6):1143-1149. PubMed ID: 30808529
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The rate of wear of second-generation highly crosslinked polyethylene liners five years post-operatively does not increase if large femoral heads are used.
    Callary SA; Field JR; Campbell DG
    Bone Joint J; 2016 Dec; 98-B(12):1604-1610. PubMed ID: 27909121
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accelerated polyethylene wear and early failure of the uncemented Reflection acetabular component: a ten to fifteen-year follow-up study.
    Clement ND; Mitchell M; Trayner ME; Porter DE; Lawson GM; Burnett R
    Int Orthop; 2013 Dec; 37(12):2337-43. PubMed ID: 23974837
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Alumina Delta-on-Highly Crosslinked-Remelted Polyethylene Bearing in Cementless Total Hip Arthroplasty in Patients Younger than 50 Years.
    Kim YH; Park JW; Kim JS
    J Arthroplasty; 2016 Dec; 31(12):2800-2804. PubMed ID: 27378639
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Comparative study on association between femoral head size and linear wear rate of highly cross-linked polyethylene liner].
    Guo S; Sun J; Zha G; Wei S; Lu Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Nov; 28(11):1333-7. PubMed ID: 25639045
    [TBL] [Abstract][Full Text] [Related]  

  • 18. What Safe Zone? The Vast Majority of Dislocated THAs Are Within the Lewinnek Safe Zone for Acetabular Component Position.
    Abdel MP; von Roth P; Jennings MT; Hanssen AD; Pagnano MW
    Clin Orthop Relat Res; 2016 Feb; 474(2):386-91. PubMed ID: 26150264
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Wear of a Highly Cross-Linked Polyethylene Liner of the Acetabular Component Placed With Excessive Acetabular Inclination.
    Tanaka S; Ito H
    Orthopedics; 2022; 45(2):e96-e100. PubMed ID: 35021024
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Thin highly cross-linked polyethylene liners combined with large femoral heads in primary total hip arthroplasty show excellent survival and low wear rates at a mean follow-up of 12.8 years.
    Fransen BL; Bengoa FJ; Neufeld ME; Sheridan GA; Garbuz DS; Howard LC
    Bone Joint J; 2023 Jan; 105-B(1):29-34. PubMed ID: 36587249
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 35.