375 related articles for article (PubMed ID: 29954216)
1. Ceramic prosthesis surfaces induce an inflammatory cell response and fibrotic tissue changes.
Bertrand J; Delfosse D; Mai V; Awiszus F; Harnisch K; Lohmann CH
Bone Joint J; 2018 Jul; 100-B(7):882-890. PubMed ID: 29954216
[TBL] [Abstract][Full Text] [Related]
2. Periprosthetic Joint Infection in Hip Arthroplasty: Is There an Association Between Infection and Bearing Surface Type?
Pitto RP; Sedel L
Clin Orthop Relat Res; 2016 Oct; 474(10):2213-8. PubMed ID: 27249955
[TBL] [Abstract][Full Text] [Related]
3. Do the Reasons for Ceramic-on-ceramic Revisions Differ From Other Bearings in Total Hip Arthroplasty?
Migaud H; Putman S; Kern G; Isida R; Girard J; Ramdane N; Delaunay CP; Hamadouche M;
Clin Orthop Relat Res; 2016 Oct; 474(10):2190-9. PubMed ID: 27255729
[TBL] [Abstract][Full Text] [Related]
4. Adverse Local Tissue Reactions are Common in Asymptomatic Individuals After Hip Resurfacing Arthroplasty: Interim Report from a Prospective Longitudinal Study.
Koff MF; Gao MA; Neri JP; Chiu YF; Lin BQ; Burge AJ; Su E; Padgett DE; Potter HG
Clin Orthop Relat Res; 2021 Dec; 479(12):2633-2650. PubMed ID: 34232144
[TBL] [Abstract][Full Text] [Related]
5. Wear of novel ceramic-on-ceramic bearings under adverse and clinically relevant hip simulator conditions.
Al-Hajjar M; Jennings LM; Begand S; Oberbach T; Delfosse D; Fisher J
J Biomed Mater Res B Appl Biomater; 2013 Nov; 101(8):1456-62. PubMed ID: 23744622
[TBL] [Abstract][Full Text] [Related]
6. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors.
Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH
Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482
[TBL] [Abstract][Full Text] [Related]
7. Do alumina matrix composite bearings decrease hip noises and bearing fractures at a minimum of 5 years after THA?
Baek SH; Kim WK; Kim JY; Kim SY
Clin Orthop Relat Res; 2015 Dec; 473(12):3796-802. PubMed ID: 26126991
[TBL] [Abstract][Full Text] [Related]
8. Revision for adverse local tissue reaction following metal-on-polyethylene total hip arthroplasty is associated with a high risk of early major complications.
Waterson HB; Whitehouse MR; Greidanus NV; Garbuz DS; Masri BA; Duncan CP
Bone Joint J; 2018 Jun; 100-B(6):720-724. PubMed ID: 29855241
[TBL] [Abstract][Full Text] [Related]
9. Ceramic on Ceramic Bearings for Dysplastic Hips: Analysis of Uncemented 2,861 THAs.
Kusaba A; Asahi M; Hirano M; Sunami H; Kondo S
J Long Term Eff Med Implants; 2020; 30(4):275-282. PubMed ID: 33463928
[TBL] [Abstract][Full Text] [Related]
10. Are ceramic-on-ceramic bearings in total hip arthroplasty associated with reduced revision risk for late dislocation?
Pitto RP; Garland M; Sedel L
Clin Orthop Relat Res; 2015 Dec; 473(12):3790-5. PubMed ID: 26070775
[TBL] [Abstract][Full Text] [Related]
11. Similar incidence of periprosthetic fluid collections after ceramic-on-polyethylene total hip arthroplasties and metal-on-metal resurfacing arthroplasties: results of a screening metal artefact reduction sequence-MRI study.
Bisseling P; de Wit BW; Hol AM; van Gorp MJ; van Kampen A; van Susante JL
Bone Joint J; 2015 Sep; 97-B(9):1175-82. PubMed ID: 26330582
[TBL] [Abstract][Full Text] [Related]
12. Outcomes of different bearings in total hip arthroplasty - implant survival, revision causes, and patient-reported outcome.
Varnum C
Dan Med J; 2017 Mar; 64(3):. PubMed ID: 28260601
[TBL] [Abstract][Full Text] [Related]
13. Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.
Nam D; Barrack T; Johnson SR; Nunley RM; Barrack RL
Clin Orthop Relat Res; 2016 Oct; 474(10):2115-22. PubMed ID: 26911973
[TBL] [Abstract][Full Text] [Related]
14. Edge loading does not increase wear rates of ceramic-on-ceramic and metal-on-polyethylene articulations.
Halma JJ; Señaris J; Delfosse D; Lerf R; Oberbach T; van Gaalen SM; de Gast A
J Biomed Mater Res B Appl Biomater; 2014 Nov; 102(8):1627-38. PubMed ID: 24652696
[TBL] [Abstract][Full Text] [Related]
15. Severe Wear and multiple Pseudotumor formation due to revision for ceramic head breakage after ceramic-on-ceramic Total hip arthroplasty: a case report.
Xing D; Yang C; Li R; Hou Y; Kou B; Li H; Lin J
BMC Musculoskelet Disord; 2019 Jul; 20(1):332. PubMed ID: 31315587
[TBL] [Abstract][Full Text] [Related]
16. How have alternative bearings and modularity affected revision rates in total hip arthroplasty?
Mihalko WM; Wimmer MA; Pacione CA; Laurent MP; Murphy RF; Rider C
Clin Orthop Relat Res; 2014 Dec; 472(12):3747-58. PubMed ID: 25070918
[TBL] [Abstract][Full Text] [Related]
17. [Low-Carbon Metal-on-Metal Articulations for Hip Arthroplasties--Evaluation of Wear and Histology after 11 to 17 Years].
Reinisch G; Huber M; Zweymüller KA
Z Orthop Unfall; 2015 Aug; 153(4):392-8. PubMed ID: 25993351
[TBL] [Abstract][Full Text] [Related]
18. Cost Analysis of Ceramic Heads in Primary Total Hip Arthroplasty.
Carnes KJ; Odum SM; Troyer JL; Fehring TK
J Bone Joint Surg Am; 2016 Nov; 98(21):1794-1800. PubMed ID: 27807111
[TBL] [Abstract][Full Text] [Related]
19. Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners?
Cafri G; Paxton EW; Love R; Bini SA; Kurtz SM
Clin Orthop Relat Res; 2017 May; 475(5):1349-1355. PubMed ID: 27385222
[TBL] [Abstract][Full Text] [Related]
20. No Threshold Exists for Recommending Revision Surgery in Metal-on-Metal Hip Arthroplasty Patients With Adverse Reactions to Metal Debris: A Retrospective Cohort Study of 346 Revisions.
Matharu GS; Berryman F; Dunlop DJ; Revell MP; Judge A; Murray DW; Pandit HG
J Arthroplasty; 2019 Jul; 34(7):1483-1491. PubMed ID: 30992241
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]