These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

375 related articles for article (PubMed ID: 29954216)

  • 21. Midterm Prospective Comparative Analysis of 2 Hard-on-Hard Bearing Total Hip Arthroplasty Designs.
    Martin JR; Jennings JM; Watters TS; Levy DL; Miner TM; Dennis DA
    J Arthroplasty; 2018 Jun; 33(6):1820-1825. PubMed ID: 29429884
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years.
    Hannouche D; Devriese F; Delambre J; Zadegan F; Tourabaly I; Sedel L; Chevret S; Nizard R
    Clin Orthop Relat Res; 2016 Feb; 474(2):520-7. PubMed ID: 26341897
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Comparison of Postoperative Complications Following Metal-on-Metal Total Hip Arthroplasty With Other Hip Bearings in Medicare Population.
    Kleeman LT; Bala A; Penrose CT; Seyler TM; Wellman SS; Bolognesi MP
    J Arthroplasty; 2018 Jun; 33(6):1826-1832. PubMed ID: 29510952
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Higher prevalence of periprosthetic fractures with ceramic on polyethylene hip bearing compared with ceramic on ceramic on the contralateral side: a forty year experience with hip osteonecrosis.
    Hernigou P; Auregan JC; Bastard C; Housset V; Flouzat-Lachaniette CH; Dubory A
    Int Orthop; 2018 Jul; 42(7):1457-1461. PubMed ID: 29504054
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Immunologic adverse reaction associated with low-carbide metal-on-metal bearings in total hip arthroplasty.
    Aroukatos P; Repanti M; Repantis T; Bravou V; Korovessis P
    Clin Orthop Relat Res; 2010 Aug; 468(8):2135-42. PubMed ID: 20020335
    [TBL] [Abstract][Full Text] [Related]  

  • 26. No Threshold Exists for Recommending Revision Surgery in Metal-on-Metal Hip Arthroplasty Patients With Adverse Reactions to Metal Debris: A Retrospective Cohort Study of 346 Revisions.
    Matharu GS; Berryman F; Dunlop DJ; Revell MP; Judge A; Murray DW; Pandit HG
    J Arthroplasty; 2019 Jul; 34(7):1483-1491. PubMed ID: 30992241
    [TBL] [Abstract][Full Text] [Related]  

  • 27. There Are No Differences in Short- to Mid-term Survivorship Among Total Hip-bearing Surface Options: A Network Meta-analysis.
    Wyles CC; Jimenez-Almonte JH; Murad MH; Norambuena-Morales GA; Cabanela ME; Sierra RJ; Trousdale RT
    Clin Orthop Relat Res; 2015 Jun; 473(6):2031-41. PubMed ID: 25516002
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Comparative effectiveness of ceramic-on-ceramic implants in stemmed hip replacement: a multinational study of six national and regional registries.
    Sedrakyan A; Graves S; Bordini B; Pons M; Havelin L; Mehle S; Paxton E; Barber T; Cafri G
    J Bone Joint Surg Am; 2014 Dec; 96 Suppl 1(Suppl 1):34-41. PubMed ID: 25520417
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Revision of ceramic head fracture after third generation ceramic-on-ceramic total hip arthroplasty.
    Koo KH; Ha YC; Kim SY; Yoon KS; Min BW; Kim SR
    J Arthroplasty; 2014 Jan; 29(1):214-8. PubMed ID: 23683525
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Five-year follow-up of a prospective randomised trial comparing ceramic-on-metal and metal-on-metal bearing surfaces in total hip arthroplasty.
    Schouten R; Malone AA; Frampton CM; Tiffen C; Hooper G
    Bone Joint J; 2017 Oct; 99-B(10):1298-1303. PubMed ID: 28963150
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions.
    Al-Hajjar M; Carbone S; Jennings LM; Begand S; Oberbach T; Delfosse D; Fisher J
    J Biomed Mater Res B Appl Biomater; 2017 Aug; 105(6):1361-1368. PubMed ID: 27062442
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Long-Term Survival of Total Hip Arthroplasty Using Implants From Different Manufacturers.
    Taylor JW; Frampton C; Rothwell AG
    J Arthroplasty; 2018 Feb; 33(2):491-495. PubMed ID: 29102074
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Mid-term results of third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty: a ten-year minimum follow-up.
    Yeung E; Bott PT; Chana R; Jackson MP; Holloway I; Walter WL; Zicat BA; Walter WK
    J Bone Joint Surg Am; 2012 Jan; 94(2):138-44. PubMed ID: 22258000
    [TBL] [Abstract][Full Text] [Related]  

  • 35. What are the current clinical issues in wear and tribocorrosion?
    Berry DJ; Abdel MP; Callaghan JJ;
    Clin Orthop Relat Res; 2014 Dec; 472(12):3659-64. PubMed ID: 24711136
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Late Dislocations After Total Hip Arthroplasty: Is the Bearing a Factor?
    Shah SM; Walter WL; Tai SM; Lorimer MF; de Steiger RN
    J Arthroplasty; 2017 Sep; 32(9):2852-2856. PubMed ID: 28529109
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Comparison of Complications Following Revision of Metal-on-Metal Versus Metal-on-Polyethylene Total Hip Arthroplasty.
    Nishio S; Fukunishi S; Yoshiya S; Sing DC; Hansen EN; Vail TP
    Orthopedics; 2017 Jan; 40(1):e164-e169. PubMed ID: 27783837
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study.
    Karidakis GK; Karachalios T
    Clin Orthop Relat Res; 2015 Dec; 473(12):3836-45. PubMed ID: 26290343
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Cementless Total Hip Arthroplasty With Metasul Bearings Provides Good Results in Active Young Patients: A Concise Followup.
    Delaunay CP; Putman S; Puliéro B; Bégin M; Migaud H; Bonnomet F
    Clin Orthop Relat Res; 2016 Oct; 474(10):2126-33. PubMed ID: 27278679
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Revision total hip arthroplasty for ceramic head fracture: a long-term follow-up.
    Sharma V; Ranawat AS; Rasquinha VJ; Weiskopf J; Howard H; Ranawat CS
    J Arthroplasty; 2010 Apr; 25(3):342-7. PubMed ID: 20347713
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 19.