These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 29955366)

  • 1. Effect of three types of horseshoes and unshod feet on selected non-podal forelimb kinematic variables measured by an extremity mounted inertial measurement unit sensor system in sound horses at the trot under conditions of treadmill and soft geotextile surface exercise.
    Stutz JC; Vidondo B; Ramseyer A; Maninchedda UE; Cruz AM
    Vet Rec Open; 2018; 5(1):e000237. PubMed ID: 29955366
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of an in-shoe pressure measurement system in horses.
    Judy CE; Galuppo LD; Snyder JR; Willits NH
    Am J Vet Res; 2001 Jan; 62(1):23-8. PubMed ID: 11197554
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Short Communication: changes in gait after 12 wk of shoeing in previously barefoot horses.
    Panos KE; Morgan K; Gately R; Wilkinson J; Uden A; Reed SA
    J Anim Sci; 2023 Jan; 101():. PubMed ID: 36383438
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Inter-evaluator and Intra-evaluator Reliability of a Software Program Used to Extract Kinematic Variables Obtained by an Extremity-Mounted Inertial Measurement Unit System in Sound Horses at the Trot Under Soft and Hard Ground Conditions and Treadmill Exercise.
    Schwarz J; Vidondo B; Maninchedda UE; Sprick M; Schöpfer MC; Cruz AM
    Front Vet Sci; 2021; 8():595455. PubMed ID: 33748204
    [No Abstract]   [Full Text] [Related]  

  • 5. Assessment of the effect of horseshoes with and without traction adaptations on the gait kinetics of nonlame horses during a trot on a concrete runway.
    Wang P; Takawira C; Taguchi T; Niu X; Nazzal MD; Lopez MJ
    Am J Vet Res; 2021 Apr; 82(4):292-301. PubMed ID: 33764831
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Adaptation strategies of horses with induced forelimb lameness walking on a treadmill.
    Serra Bragança FM; Hernlund E; Thomsen MH; Waldern NM; Rhodin M; Byström A; van Weeren PR; Weishaupt MA
    Equine Vet J; 2021 May; 53(3):600-611. PubMed ID: 32888199
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of distal limb mounted inertial measurement unit sensors for stride detection in Warmblood horses at walk and trot.
    Bragança FM; Bosch S; Voskamp JP; Marin-Perianu M; Van der Zwaag BJ; Vernooij JCM; van Weeren PR; Back W
    Equine Vet J; 2017 Jul; 49(4):545-551. PubMed ID: 27862238
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of 'navicular' shoeing on equine distal forelimb kinematics on different track surface.
    Scheffer CJ; Back W
    Vet Q; 2001 Nov; 23(4):191-5. PubMed ID: 11765238
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Fetlock Joint Angle Pattern and Range of Motion Quantification Using Two Synchronized Wearable Inertial Sensors per Limb in Sound Horses and Horses with Single Limb Naturally Occurring Lameness.
    Pagliara E; Marenchino M; Antenucci L; Costantini M; Zoppi G; Giacobini MDL; Bullone M; Riccio B; Bertuglia A
    Vet Sci; 2022 Aug; 9(9):. PubMed ID: 36136672
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of trotting speed on kinematic variables measured by use of extremity-mounted inertial measurement units in nonlame horses performing controlled treadmill exercise.
    Cruz AM; Vidondo B; Ramseyer AA; Maninchedda UE
    Am J Vet Res; 2018 Feb; 79(2):211-218. PubMed ID: 29359977
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Can the hoof be shod without limiting the heel movement? A comparative study between barefoot, shoeing with conventional shoes and a split-toe shoe.
    Brunsting J; Dumoulin M; Oosterlinck M; Haspeslagh M; Lefère L; Pille F
    Vet J; 2019 Apr; 246():7-11. PubMed ID: 30902192
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of different shoeing conditions on equine cervical and back kinematics during walking and trotting on a soft surface.
    Caure S; Dendauw P; Thesee L; Villedey E; Malinvaud A; Cousty M; Prie V; Horan K; Weller R
    J Equine Vet Sci; 2024 Nov; 142():105194. PubMed ID: 39276952
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Influence of trimming, hoof angle and shoeing on breakover duration in sound horses examined with hoof-mounted inertial sensors.
    Hagen J; Bos R; Brouwer J; Lux S; Jung FT
    Vet Rec; 2021 Aug; 189(4):e450. PubMed ID: 33993524
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Toe modifications in hind feet shoes optimise hoof-unrollment in sound Warmblood horses at trot.
    Spaak B; van Heel MC; Back W
    Equine Vet J; 2013 Jul; 45(4):485-9. PubMed ID: 23094947
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Repeatability of gait pattern variables measured by use of extremity-mounted inertial measurement units in nonlame horses during trotting.
    Cruz AM; Maninchedda UE; Burger D; Wanda S; Vidondo B
    Am J Vet Res; 2017 Sep; 78(9):1011-1018. PubMed ID: 28836845
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Use of an inertial measurement unit to assess the effect of forelimb lameness on three-dimensional hoof orientation in horses at a walk and trot.
    Moorman VJ; Reiser RF; Mahaffey CA; Peterson ML; McIlwraith CW; Kawcak CE
    Am J Vet Res; 2014 Sep; 75(9):800-8. PubMed ID: 25157883
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of limb kinematics between collected and lengthened (medium/extended) trot in two groups of dressage horses on two different surfaces.
    Walker VA; Tranquille CA; Newton JR; Dyson SJ; Brandham J; Northrop AJ; Murray RC
    Equine Vet J; 2017 Sep; 49(5):673-680. PubMed ID: 28052378
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Does 'hacking' surface type affect equine forelimb foot placement, movement symmetry or hoof impact deceleration during ridden walk and trot exercise?
    Barstow A; Bailey J; Campbell J; Harris C; Weller R; Pfau T
    Equine Vet J; 2019 Jan; 51(1):108-114. PubMed ID: 29665054
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validity of shoe-type inertial measurement units for Parkinson's disease patients during treadmill walking.
    Lee M; Youm C; Jeon J; Cheon SM; Park H
    J Neuroeng Rehabil; 2018 May; 15(1):38. PubMed ID: 29764466
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of induced forelimb lameness on thoracolumbar kinematics during treadmill locomotion.
    Gómez Alvarez CB; Wennerstrand J; Bobbert MF; Lamers L; Johnston C; Back W; van Weeren PR
    Equine Vet J; 2007 May; 39(3):197-201. PubMed ID: 17520968
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.