These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

272 related articles for article (PubMed ID: 29955754)

  • 1. A fluorometric skin-interfaced microfluidic device and smartphone imaging module for in situ quantitative analysis of sweat chemistry.
    Sekine Y; Kim SB; Zhang Y; Bandodkar AJ; Xu S; Choi J; Irie M; Ray TR; Kohli P; Kozai N; Sugita T; Wu Y; Lee K; Lee KT; Ghaffari R; Rogers JA
    Lab Chip; 2018 Jul; 18(15):2178-2186. PubMed ID: 29955754
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Soft, skin-interfaced microfluidic systems with integrated immunoassays, fluorometric sensors, and impedance measurement capabilities.
    Kim S; Lee B; Reeder JT; Seo SH; Lee SU; Hourlier-Fargette A; Shin J; Sekine Y; Jeong H; Oh YS; Aranyosi AJ; Lee SP; Model JB; Lee G; Seo MH; Kwak SS; Jo S; Park G; Han S; Park I; Jung HI; Ghaffari R; Koo J; Braun PV; Rogers JA
    Proc Natl Acad Sci U S A; 2020 Nov; 117(45):27906-27915. PubMed ID: 33106394
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Soft, Skin-Interfaced Microfluidic Systems with Passive Galvanic Stopwatches for Precise Chronometric Sampling of Sweat.
    Bandodkar AJ; Choi J; Lee SP; Jeang WJ; Agyare P; Gutruf P; Wang S; Sponenburg RA; Reeder JT; Schon S; Ray TR; Chen S; Mehta S; Ruiz S; Rogers JA
    Adv Mater; 2019 Aug; 31(32):e1902109. PubMed ID: 31206791
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Soft, Skin-Integrated Multifunctional Microfluidic Systems for Accurate Colorimetric Analysis of Sweat Biomarkers and Temperature.
    Choi J; Bandodkar AJ; Reeder JT; Ray TR; Turnquist A; Kim SB; Nyberg N; Hourlier-Fargette A; Model JB; Aranyosi AJ; Xu S; Ghaffari R; Rogers JA
    ACS Sens; 2019 Feb; 4(2):379-388. PubMed ID: 30707572
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat.
    Koh A; Kang D; Xue Y; Lee S; Pielak RM; Kim J; Hwang T; Min S; Banks A; Bastien P; Manco MC; Wang L; Ammann KR; Jang KI; Won P; Han S; Ghaffari R; Paik U; Slepian MJ; Balooch G; Huang Y; Rogers JA
    Sci Transl Med; 2016 Nov; 8(366):366ra165. PubMed ID: 27881826
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Enhancing On-Skin Analysis: A Microfluidic Device and Smartphone Imaging Module for Real-Time Quantitative Detection of Multianalytes in Sweat.
    Dashtian K; Binabaji F; Zare-Dorabei R
    Anal Chem; 2023 Nov; 95(44):16315-16326. PubMed ID: 37897415
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Towards smart personalized perspiration analysis: An IoT-integrated cellulose-based microfluidic wearable patch for smartphone fluorimetric multi-sensing of sweat biomarkers.
    Ardalan S; Hosseinifard M; Vosough M; Golmohammadi H
    Biosens Bioelectron; 2020 Nov; 168():112450. PubMed ID: 32877780
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat.
    Bandodkar AJ; Gutruf P; Choi J; Lee K; Sekine Y; Reeder JT; Jeang WJ; Aranyosi AJ; Lee SP; Model JB; Ghaffari R; Su CJ; Leshock JP; Ray T; Verrillo A; Thomas K; Krishnamurthi V; Han S; Kim J; Krishnan S; Hang T; Rogers JA
    Sci Adv; 2019 Jan; 5(1):eaav3294. PubMed ID: 30746477
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Soft, skin-interfaced microfluidic systems with integrated enzymatic assays for measuring the concentration of ammonia and ethanol in sweat.
    Kim SB; Koo J; Yoon J; Hourlier-Fargette A; Lee B; Chen S; Jo S; Choi J; Oh YS; Lee G; Won SM; Aranyosi AJ; Lee SP; Model JB; Braun PV; Ghaffari R; Park C; Rogers JA
    Lab Chip; 2020 Jan; 20(1):84-92. PubMed ID: 31776526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Soft, Skin-Interfaced Microfluidic Systems with Wireless, Battery-Free Electronics for Digital, Real-Time Tracking of Sweat Loss and Electrolyte Composition.
    Kim SB; Lee K; Raj MS; Lee B; Reeder JT; Koo J; Hourlier-Fargette A; Bandodkar AJ; Won SM; Sekine Y; Choi J; Zhang Y; Yoon J; Kim BH; Yun Y; Lee S; Shin J; Kim J; Ghaffari R; Rogers JA
    Small; 2018 Nov; 14(45):e1802876. PubMed ID: 30300469
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Skin-interfaced microfluidic systems with spatially engineered 3D fluidics for sweat capture and analysis.
    Wu CH; Ma HJH; Baessler P; Balanay RK; Ray TR
    Sci Adv; 2023 May; 9(18):eadg4272. PubMed ID: 37134158
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Skin-interfaced microfluidic biosensors for colorimetric measurements of the concentrations of ketones in sweat.
    Wu Y; Li X; Madsen KE; Zhang H; Cho S; Song R; Nuxoll RF; Xiong Y; Liu J; Feng J; Yang T; Zhang K; Aranyosi AJ; Wright DE; Ghaffari R; Huang Y; Nuzzo RG; Rogers JA
    Lab Chip; 2024 Sep; 24(18):4288-4295. PubMed ID: 39193649
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Three-Dimensional Integrated Ultra-Low-Volume Passive Microfluidics with Ion-Sensitive Field-Effect Transistors for Multiparameter Wearable Sweat Analyzers.
    Garcia-Cordero E; Bellando F; Zhang J; Wildhaber F; Longo J; Guérin H; Ionescu AM
    ACS Nano; 2018 Dec; 12(12):12646-12656. PubMed ID: 30543395
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A Skin-Interfaced, Miniaturized Microfluidic Analysis and Delivery System for Colorimetric Measurements of Nutrients in Sweat and Supply of Vitamins Through the Skin.
    Kim J; Wu Y; Luan H; Yang DS; Cho D; Kwak SS; Liu S; Ryu H; Ghaffari R; Rogers JA
    Adv Sci (Weinh); 2022 Jan; 9(2):e2103331. PubMed ID: 34747140
    [TBL] [Abstract][Full Text] [Related]  

  • 15. 3D-printed epidermal sweat microfluidic systems with integrated microcuvettes for precise spectroscopic and fluorometric biochemical assays.
    Yang DS; Wu Y; Kanatzidis EE; Avila R; Zhou M; Bai Y; Chen S; Sekine Y; Kim J; Deng Y; Guo H; Zhang Y; Ghaffari R; Huang Y; Rogers JA
    Mater Horiz; 2023 Oct; 10(11):4992-5003. PubMed ID: 37641877
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Soft, skin-interfaced sweat stickers for cystic fibrosis diagnosis and management.
    Ray TR; Ivanovic M; Curtis PM; Franklin D; Guventurk K; Jeang WJ; Chafetz J; Gaertner H; Young G; Rebollo S; Model JB; Lee SP; Ciraldo J; Reeder JT; Hourlier-Fargette A; Bandodkar AJ; Choi J; Aranyosi AJ; Ghaffari R; McColley SA; Haymond S; Rogers JA
    Sci Transl Med; 2021 Mar; 13(587):. PubMed ID: 33790027
    [TBL] [Abstract][Full Text] [Related]  

  • 17. State of Sweat: Emerging Wearable Systems for Real-Time, Noninvasive Sweat Sensing and Analytics.
    Ghaffari R; Yang DS; Kim J; Mansour A; Wright JA; Model JB; Wright DE; Rogers JA; Ray TR
    ACS Sens; 2021 Aug; 6(8):2787-2801. PubMed ID: 34351759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A thread/fabric-based band as a flexible and wearable microfluidic device for sweat sensing and monitoring.
    Zhao Z; Li Q; Chen L; Zhao Y; Gong J; Li Z; Zhang J
    Lab Chip; 2021 Mar; 21(5):916-932. PubMed ID: 33438703
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Skin-interfaced soft microfluidic systems with modular and reusable electronics for
    Hourlier-Fargette A; Schon S; Xue Y; Avila R; Li W; Gao Y; Liu C; Kim SB; Raj MS; Fields KB; Parsons BV; Lee K; Lee JY; Chung HU; Lee SP; Johnson M; Bandodkar AJ; Gutruf P; Model JB; Aranyosi AJ; Choi J; Ray TR; Ghaffari R; Huang Y; Rogers JA
    Lab Chip; 2020 Nov; 20(23):4391-4403. PubMed ID: 33089837
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Waterproof, electronics-enabled, epidermal microfluidic devices for sweat collection, biomarker analysis, and thermography in aquatic settings.
    Reeder JT; Choi J; Xue Y; Gutruf P; Hanson J; Liu M; Ray T; Bandodkar AJ; Avila R; Xia W; Krishnan S; Xu S; Barnes K; Pahnke M; Ghaffari R; Huang Y; Rogers JA
    Sci Adv; 2019 Jan; 5(1):eaau6356. PubMed ID: 30746456
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.