These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
282 related articles for article (PubMed ID: 29958004)
1. Accuracy of the Haigis and SRK/T Formulas in Eyes Longer than 29.0 mm and the Influence of Central Corneal Keratometry Reading. Zhang Z; Miao Y; Fang X; Luo Q; Wang Y Curr Eye Res; 2018 Nov; 43(11):1316-1321. PubMed ID: 29958004 [TBL] [Abstract][Full Text] [Related]
2. [The analysis of refractive error of long axial high myopic eyes after IOL implantation]. Zheng Q; Zhao Z; Lian H; Zhao Y Zhonghua Yan Ke Za Zhi; 2015 Apr; 51(4):276-81. PubMed ID: 26081231 [TBL] [Abstract][Full Text] [Related]
3. [Intraocular lens power calculation for high myopic eyes with cataract: comparison of three formulas]. Zhu XJ; He WW; Du Y; Qian DJ; Dai JH; Lu Y Zhonghua Yan Ke Za Zhi; 2017 Apr; 53(4):260-265. PubMed ID: 28412798 [No Abstract] [Full Text] [Related]
4. Comparison of refractive outcomes using conventional keratometry or total keratometry for IOL power calculation in cataract surgery. Srivannaboon S; Chirapapaisan C Graefes Arch Clin Exp Ophthalmol; 2019 Dec; 257(12):2677-2682. PubMed ID: 31486917 [TBL] [Abstract][Full Text] [Related]
5. Intraocular lens power calculation in eyes with keratoconus. Savini G; Abbate R; Hoffer KJ; Mularoni A; Imburgia A; Avoni L; D'Eliseo D; Schiano-Lomoriello D J Cataract Refract Surg; 2019 May; 45(5):576-581. PubMed ID: 30799180 [TBL] [Abstract][Full Text] [Related]
6. Outcomes of the Haigis-L formula for calculating intraocular lens power in extreme long axis eyes after myopic laser in situ keratomileusis. Fang X; Ben S; Dong Y; Chen X; Xue W; Wang Y Eye (Lond); 2022 Jun; 36(6):1178-1184. PubMed ID: 34117389 [TBL] [Abstract][Full Text] [Related]
7. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas. Jeong J; Song H; Lee JK; Chuck RS; Kwon JW BMC Ophthalmol; 2017 May; 17(1):62. PubMed ID: 28464806 [TBL] [Abstract][Full Text] [Related]
8. Assessment of the influence of keratometry on intraocular lens calculation formulas in long axial length eyes. Yin S; Guo C; Qiu K; Ng TK; Li Y; Du Y; Chen B; Wang H; Zhang M Int Ophthalmol; 2022 Oct; 42(10):3211-3219. PubMed ID: 36057757 [TBL] [Abstract][Full Text] [Related]
9. Accuracy of Constant C for Ray Tracing: Assisted Intraocular Lens Power Calculation in Normal Ocular Axial Eyes. Chang PJ; Zhang F; Wang JJ; Zhao YE Ophthalmic Res; 2021; 64(1):85-90. PubMed ID: 32305980 [TBL] [Abstract][Full Text] [Related]
10. Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length. Kim JW; Eom Y; Yoon EG; Choi Y; Song JS; Jeong JW; Park SK; Kim HM Acta Ophthalmol; 2022 May; 100(3):e701-e709. PubMed ID: 34378871 [TBL] [Abstract][Full Text] [Related]
11. Influence of corneal asphericity on the refractive outcome of intraocular lens implantation in cataract surgery. Savini G; Hoffer KJ; Barboni P J Cataract Refract Surg; 2015 Apr; 41(4):785-9. PubMed ID: 25840302 [TBL] [Abstract][Full Text] [Related]
12. Refractive outcomes of intraocular lens power calculation using different corneal power measurements with a new optical biometer. Savini G; Negishi K; Hoffer KJ; Schiano Lomoriello D J Cataract Refract Surg; 2018 Jun; 44(6):701-708. PubMed ID: 29861053 [TBL] [Abstract][Full Text] [Related]
13. Comparison of IOL Power Calculation Formulas for a Trifocal IOL in Eyes With High Myopia. Tan Q; Lin D; Wang L; Chen B; Tang Q; Chen X; Chen M; Tan J; Zhang J; Wu L; Zhu X; Wang Y J Refract Surg; 2021 Aug; 37(8):538-544. PubMed ID: 34388073 [TBL] [Abstract][Full Text] [Related]
14. Performance of the SRK/T formula using A-Scan ultrasound biometry after phacoemulsification in eyes with short and long axial lengths. Karabela Y; Eliacik M; Kaya F BMC Ophthalmol; 2016 Jul; 16():96. PubMed ID: 27391470 [TBL] [Abstract][Full Text] [Related]
15. Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method. Kim M; Eom Y; Lee H; Suh YW; Song JS; Kim HM Invest Ophthalmol Vis Sci; 2018 Feb; 59(2):1016-1024. PubMed ID: 29450545 [TBL] [Abstract][Full Text] [Related]
16. Comparison of SRK/T and Haigis formulas for predicting corneal astigmatism correction with toric intraocular lenses. Eom Y; Song JS; Kim YY; Kim HM J Cataract Refract Surg; 2015 Aug; 41(8):1650-7. PubMed ID: 26432122 [TBL] [Abstract][Full Text] [Related]
17. Intraocular lens power calculation using IOLMaster and various formulas in short eyes. Roh YR; Lee SM; Han YK; Kim MK; Wee WR; Lee JH Korean J Ophthalmol; 2011 Jun; 25(3):151-5. PubMed ID: 21655038 [TBL] [Abstract][Full Text] [Related]
18. [Comparison of the accuracy of intraocular lens power calculation formulas based on the new swept-source optical coherence tomography biometry]. Deng XH; Chang PJ; Huang JH; Wang DD; Zhao YY; Ding XX; Zhao YE Zhonghua Yan Ke Za Zhi; 2021 Jul; 57(7):502-511. PubMed ID: 34256470 [No Abstract] [Full Text] [Related]
19. Accuracy of intraocular lens calculation formulas in cataract patients with steep corneal curvature. Zhang C; Dai G; Pazo EE; Xu L; Wu X; Zhang H; Lin T; He W PLoS One; 2020; 15(11):e0241630. PubMed ID: 33216749 [TBL] [Abstract][Full Text] [Related]
20. [Alternative method of intraocular lens power calculation in eyes with short axial length]. Belov DF; Nikolaenko VP Vestn Oftalmol; 2022; 138(3):24-28. PubMed ID: 35801876 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]