These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 29959078)

  • 1. Perioperative Measurement of Radiation Exposure to Radiation-Sensitive Organs of Patients Undergoing Lumbar Surgeries Using a Thermoluminescent Dosimeter.
    Chen X; Song Y; Li Z; Luo S; Yue B; Xu H; He Z; Ren Z; Xu D; Li S
    World Neurosurg; 2018 Oct; 118():e43-e51. PubMed ID: 29959078
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery.
    Lange J; Karellas A; Street J; Eck JC; Lapinsky A; Connolly PJ; Dipaola CP
    Spine (Phila Pa 1976); 2013 Mar; 38(5):E306-12. PubMed ID: 23238490
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dose absorption in lumbar and femoral dual energy X-ray absorptiometry examinations using three different scan modalities: an anthropomorphic phantom study.
    Bandirali M; Lanza E; Messina C; Sconfienza LM; Brambilla R; Maurizio R; Marchelli D; Piodi LP; Di Leo G; Ulivieri FM; Sardanelli F
    J Clin Densitom; 2013; 16(3):279-282. PubMed ID: 23535250
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automatic exposure control in pediatric and adult computed tomography examinations: can we estimate organ and effective dose from mean MAS reduction?
    Papadakis AE; Perisinakis K; Oikonomou I; Damilakis J
    Invest Radiol; 2011 Oct; 46(10):654-62. PubMed ID: 21673583
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Radiation dose of cone-beam computed tomography compared to conventional radiographs in orthodontics.
    Signorelli L; Patcas R; Peltomäki T; Schätzle M
    J Orofac Orthop; 2016 Jan; 77(1):9-15. PubMed ID: 26747662
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Dose reduction in maxillofacial imaging using low dose Cone Beam CT.
    Tsiklakis K; Donta C; Gavala S; Karayianni K; Kamenopoulou V; Hourdakis CJ
    Eur J Radiol; 2005 Dec; 56(3):413-7. PubMed ID: 15978765
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Radiation exposure of patients who undergo CT of the trunk.
    Mini RL; Vock P; Mury R; Schneeberger PP
    Radiology; 1995 May; 195(2):557-62. PubMed ID: 7724783
    [TBL] [Abstract][Full Text] [Related]  

  • 8. MEASUREMENTS OF RADIATION EXPOSURE OF RADIOGRAPHY STUDENTS DURING THEIR CLINICAL TRAINING USING THERMOLUMINESCENT DOSIMETRY.
    Abuzaid MM; Elshami W; Steelman C
    Radiat Prot Dosimetry; 2018 May; 179(3):244-247. PubMed ID: 29186490
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Radiation exposure to the surgeon during percutaneous endoscopic lumbar discectomy: a prospective study.
    Ahn Y; Kim CH; Lee JH; Lee SH; Kim JS
    Spine (Phila Pa 1976); 2013 Apr; 38(7):617-25. PubMed ID: 23026867
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Estimation of occupational radiation doses in neuroendovascular procedures.
    López-Ángeles D; Gamboa-deBuen I; Martínez-de Los Santos C; Alaniz-Sida K; Vega-Montesinos S; Lopez-Rendon X
    J Radiol Prot; 2021 Nov; 41(4):. PubMed ID: 34348239
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Skin and thyroid dosimetry in cervical spine screening: two methods for evaluation and a comparison between a helical CT and radiographic trauma series.
    Rybicki F; Nawfel RD; Judy PF; Ledbetter S; Dyson RL; Halt PS; Shu KM; Nuñez DB
    AJR Am J Roentgenol; 2002 Oct; 179(4):933-7. PubMed ID: 12239041
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of breast absorbed doses during thoracic computed tomography scan to evaluate the effectiveness of bismuth shielding.
    Alonso TC; Mourão AP; Santana PC; da Silva TA
    Appl Radiat Isot; 2016 Nov; 117():55-57. PubMed ID: 27033028
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of a full and empty bladder on radiation dose to the uterus, ovaries and bladder from lumbar spine CT and X-ray examinations.
    Nicholson R; Coucher J; Thornton A; Connor F
    Br J Radiol; 2000 Dec; 73(876):1290-6. PubMed ID: 11205673
    [TBL] [Abstract][Full Text] [Related]  

  • 14. "Anode heel effect" on patient dose in lumbar spine radiography.
    Fung KK; Gilboy WB
    Br J Radiol; 2000 May; 73(869):531-6. PubMed ID: 10884750
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Radiation protection in CT pelvis in Fantoma Rando by thermoluminescent dosimetry.
    Madrid-González OA; Rivera-Montalvo T; Azorín-Nieto J
    Appl Radiat Isot; 2012 Dec; 71 Suppl():40-3. PubMed ID: 22898298
    [TBL] [Abstract][Full Text] [Related]  

  • 16. TLD assessment of mouse dosimetry during microCT imaging.
    Figueroa SD; Winkelmann CT; Miller HW; Volkert WA; Hoffman TJ
    Med Phys; 2008 Sep; 35(9):3866-74. PubMed ID: 18841837
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fluoroscopically guided percutaneous vertebroplasty: assessment of radiation doses and implementation of procedural routines to reduce operator exposure.
    von Wrangel A; Cederblad A; Rodriguez-Catarino M
    Acta Radiol; 2009 Jun; 50(5):490-6. PubMed ID: 19363715
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Low-dose computed tomography of the lumbar spine: a phantom study on imaging parameters and image quality.
    Alshamari M; Geijer M; Norrman E; Geijer H
    Acta Radiol; 2014 Sep; 55(7):824-32. PubMed ID: 24215904
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Patient and surgeon radiation exposure during spinal instrumentation using intraoperative computed tomography-based navigation.
    Mendelsohn D; Strelzow J; Dea N; Ford NL; Batke J; Pennington A; Yang K; Ailon T; Boyd M; Dvorak M; Kwon B; Paquette S; Fisher C; Street J
    Spine J; 2016 Mar; 16(3):343-54. PubMed ID: 26686604
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Radiation exposure to the spine surgeon in lumbar and thoracolumbar fusions with the use of an intraoperative computed tomographic 3-dimensional imaging system.
    Abdullah KG; Bishop FS; Lubelski D; Steinmetz MP; Benzel EC; Mroz TE
    Spine (Phila Pa 1976); 2012 Aug; 37(17):E1074-8. PubMed ID: 22472810
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.