These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 29960511)

  • 1. Note: Measurement of the cathode layer thickness in glow discharges with a Langmuir probe.
    Wang H; Hou X; Zou X; Luo H; Wang X
    Rev Sci Instrum; 2018 Jun; 89(6):066103. PubMed ID: 29960511
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Spectroscopic characteristics of DC excited atmospheric pressure glow discharges generated in a needle-plate electrode device and a needle-water electrode one].
    Li XC; Bao WT; Jia PY; Zhao HH; Di C
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Jan; 34(1):16-9. PubMed ID: 24783524
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hollow Cathode Discharges: Analytical Applications.
    Mavrodineanu R
    J Res Natl Bur Stand (1977); 1984; 89(2):143-185. PubMed ID: 34566122
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Glow Discharge Characteristics of Hollow Needle-Plate Electrode in Atmospheric Pressure Argon].
    Liu SH; Jia PY; Di C; Li XC; Yang F
    Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Sep; 35(9):2473-7. PubMed ID: 26669150
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Measurement of rotational temperature in N2 DC glow discharge by optical emission spectroscopy].
    Liu LY; Zhang JL; Ma TC; Deng XL
    Guang Pu Xue Yu Guang Pu Fen Xi; 2002 Dec; 22(6):1013-8. PubMed ID: 12914187
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Bifurcations of current transfer through a collisional sheath with ionization and self-organization on glow cathodes.
    Benilov MS
    Phys Rev E Stat Nonlin Soft Matter Phys; 2008 Mar; 77(3 Pt 2):036408. PubMed ID: 18517534
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Apparent secondary-electron emission coefficient and the voltage-current characteristics of argon glow discharges.
    Donkó Z
    Phys Rev E Stat Nonlin Soft Matter Phys; 2001 Aug; 64(2 Pt 2):026401. PubMed ID: 11497705
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The design and characteristics of direct current glow discharge atomic emission source operated with plain and hollow cathodes.
    Qayyum A; Mahmood MI
    Anal Chim Acta; 2008 Jan; 606(1):108-11. PubMed ID: 18068777
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Spatial distribution of electrons with high energy in atmospheric pressure glow discharge excited by DC voltage].
    Liu ZQ; Jia PY; Liu T
    Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Sep; 33(9):2321-4. PubMed ID: 24369623
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Rotational temperature of nitrogen glow discharge obtained by optical emission spectroscopy.
    Zhang J; Liu L; Ma T; Deng X
    Spectrochim Acta A Mol Biomol Spectrosc; 2002 Jul; 58(9):1915-22. PubMed ID: 12164491
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Verification of high efficient broad beam cold cathode ion source.
    Abdel Reheem AM; Ahmed MM; Abdelhamid MM; Ashour AH
    Rev Sci Instrum; 2016 Aug; 87(8):083302. PubMed ID: 27587108
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Double flush-mounted probe diagnostics and data analysis technique for argon glow discharge plasma.
    Yu P; Liu Y; Cao J; Xu L; Zhang X; Zhang Z; Wang P
    Rev Sci Instrum; 2017 Jan; 88(1):013502. PubMed ID: 28147698
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Design and experiment of a needle-to-cylinder electrode structure realizing the negative DC glow discharge in ambient air].
    Li H; Wei CY; Liu CX; Shen XH; Chen ZC
    Guang Pu Xue Yu Guang Pu Fen Xi; 2014 Jul; 34(7):1797-800. PubMed ID: 25269283
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mathematical description of a direct current glow discharge in argon.
    Bogaerts A; Gijbels R
    Anal Bioanal Chem; 1996 Jul; 355(7-8):853-7. PubMed ID: 15045278
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Rydberg gas theory of a glow discharge plasma: I. Application to the electrical behaviour of a fast flowing glow discharge plasma.
    Mason RS; Mitchell DJ; Dickinson PM
    Phys Chem Chem Phys; 2010 Apr; 12(15):3698-717. PubMed ID: 20358066
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Microbial fuel cell cathodes with poly(dimethylsiloxane) diffusion layers constructed around stainless steel mesh current collectors.
    Zhang F; Saito T; Cheng S; Hickner MA; Logan BE
    Environ Sci Technol; 2010 Feb; 44(4):1490-5. PubMed ID: 20099808
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Spectroscopic study of atmospheric pressure argon DC microdischarge].
    Zheng PC; Wang HM; Li JQ; Han HY; Xu GH; Shen CY; Chu YN
    Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Oct; 28(10):2224-7. PubMed ID: 19123377
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Using a direct current (DC) glow discharge electrode as a non-invasive impedance probe for measuring electron density.
    Gillman ED; Tejero E; Blackwell D; Amatucci WE
    Rev Sci Instrum; 2018 Nov; 89(11):113505. PubMed ID: 30501359
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Broadband microwave characteristics of a novel coaxial gridded hollow cathode argon plasma.
    Gao R; Yuan C; Li H; Jia J; Zhou ZX; Wang Y; Wang X; Wu J
    Rev Sci Instrum; 2016 Aug; 87(8):083506. PubMed ID: 27587122
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Analysis of double-probe characteristics in low-frequency gas discharges and its improvement.
    Liu D; Li X; Xie K; Liu Z; Shao M
    Rev Sci Instrum; 2015 Jan; 86(1):013504. PubMed ID: 25638083
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.