123 related articles for article (PubMed ID: 29960515)
1. Characterisation of a sub-20 ps temporal resolution pulse dilation photomultiplier tube.
Gales SG; Horsfield CJ; Meadowcroft AL; Leatherland AE; Herrmann HW; Hares JD; Dymoke-Bradshaw AKL; Milnes JS; Kim YH; Kleinrath HG; Meaney K; Zylstra AB; Parker S; Hussey D; Wilson L; James SF; Kilkenny JD; Hilsabeck TJ
Rev Sci Instrum; 2018 Jun; 89(6):063506. PubMed ID: 29960515
[TBL] [Abstract][Full Text] [Related]
2. Pulse dilation gas Cherenkov detector for ultra-fast gamma reaction history at the NIF (invited).
Geppert-Kleinrath H; Herrmann HW; Kim YH; Zylstra AB; Meaney K; Lopez FE; Pederson BJ; Carrera J; Khater H; Horsfield CJ; Rubery MS; Gales S; Leatherland A; Meadowcroft A; Hilsabeck T; Kilkenny JD; Malone RM; Hares JD; Dymoke-Bradshaw AKL; Milnes J; McFee C
Rev Sci Instrum; 2018 Oct; 89(10):10I146. PubMed ID: 30399731
[TBL] [Abstract][Full Text] [Related]
3. Development of an ultra-fast photomultiplier tube for gamma-ray Cherenkov detectors at the National Ignition Facility (PD-PMT).
Dymoke-Bradshaw AKL; Hares JD; Milnes J; Herrmann HW; Horsfield CJ; Gales SG; Leatherland A; Hilsabeck T; Kilkenny JD
Rev Sci Instrum; 2018 Oct; 89(10):10I137. PubMed ID: 30399690
[TBL] [Abstract][Full Text] [Related]
4. Progress on next generation gamma-ray Cherenkov detectors for the National Ignition Facility.
Herrmann HW; Kim YH; Zylstra AB; Geppert-Kleinrath H; Meaney KD; Young CS; Lopez FE; Fatherley VE; Pederson BJ; Oertel JA; Hernandez JE; Carrera J; Khater H; Rubery MS; Horsfield CJ; Gales S; Leatherland A; Hilsabeck T; Kilkenny JD; Malone RM; Batha SH
Rev Sci Instrum; 2018 Oct; 89(10):10I148. PubMed ID: 30399772
[TBL] [Abstract][Full Text] [Related]
5. Pulse-dilation enhanced gated optical imager with 5 ps resolution (invited).
Hilsabeck TJ; Hares JD; Kilkenny JD; Bell PM; Dymoke-Bradshaw AK; Koch JA; Celliers PM; Bradley DK; McCarville T; Pivovaroff M; Soufli R; Bionta R
Rev Sci Instrum; 2010 Oct; 81(10):10E317. PubMed ID: 21034015
[TBL] [Abstract][Full Text] [Related]
6. Development and characterization of sub-100 ps photomultiplier tubes.
Horsfield CJ; Rubery MS; Mack JM; Young CS; Herrmann HW; Caldwell SE; Evans SC; Sedilleo TJ; Kim YH; McEvoy A; Milnes JS; Howorth J; Davis B; O'Gara PM; Garza I; Miller EK; Stoeffl W; Ali Z
Rev Sci Instrum; 2010 Oct; 81(10):10D318. PubMed ID: 21033844
[TBL] [Abstract][Full Text] [Related]
7. Next generation gamma-ray Cherenkov detectors for the National Ignition Facility.
Herrmann HW; Kim YH; McEvoy AM; Zylstra AB; Young CS; Lopez FE; Griego JR; Fatherley VE; Oertel JA; Stoeffl W; Khater H; Hernandez JE; Carpenter A; Rubery MS; Horsfield CJ; Gales S; Leatherland A; Hilsabeck T; Kilkenny JD; Malone RM; Hares JD; Milnes J; Shmayda WT; Stoeckl C; Batha SH
Rev Sci Instrum; 2016 Nov; 87(11):11E732. PubMed ID: 27910331
[TBL] [Abstract][Full Text] [Related]
8. X-ray streak camera cathode development and timing accuracy of the 4ω ultraviolet fiducial system at the National Ignition Facility.
Opachich YP; Palmer N; Homoelle D; Hatch B; Bell P; Bradley D; Kalantar D; Browning D; Zuegel J; Landen O
Rev Sci Instrum; 2012 Oct; 83(10):10E123. PubMed ID: 23126945
[TBL] [Abstract][Full Text] [Related]
9. Dilation x-ray framing camera and its temporal resolution uniformity.
Cai H; Fu W; Wang D; Lei Y; Liu J
Opt Express; 2019 Feb; 27(3):2817-2827. PubMed ID: 30732313
[TBL] [Abstract][Full Text] [Related]
10. Synchronous gating in dilation x-ray detector without 1:1 image ratio.
Cai H; Fu W; Wang D; Lei Y; Liu J
Opt Express; 2019 Apr; 27(9):12470-12482. PubMed ID: 31052786
[TBL] [Abstract][Full Text] [Related]
11. Investigating high speed phenomena in laser plasma interactions using dilation x-ray imager (invited).
Nagel SR; Hilsabeck TJ; Bell PM; Bradley DK; Ayers MJ; Piston K; Felker B; Kilkenny JD; Chung T; Sammuli B; Hares JD; Dymoke-Bradshaw AK
Rev Sci Instrum; 2014 Nov; 85(11):11E504. PubMed ID: 25430346
[TBL] [Abstract][Full Text] [Related]
12. Laser induced breakdown spectroscopy of pure aluminum with high temporal resolution.
Li YT; Liu TA; Chen CW; Lee YH; Yabushita A
Opt Express; 2013 Sep; 21(18):21579-86. PubMed ID: 24104032
[TBL] [Abstract][Full Text] [Related]
13. Monte Carlo validation experiments for the gas Cherenkov detectors at the National Ignition Facility and Omega.
Rubery MS; Horsfield CJ; Herrmann H; Kim Y; Mack JM; Young C; Evans S; Sedillo T; McEvoy A; Caldwell SE; Grafil E; Stoeffl W; Milnes JS
Rev Sci Instrum; 2013 Jul; 84(7):073504. PubMed ID: 23902060
[TBL] [Abstract][Full Text] [Related]
14. Characterization of photodetector temporal response for neutron time-of-flight (nToF) diagnostics at the National Ignition Facility.
Gordon JM; Schlossberg DJ; Eckart MJ; Datte PS; Durand CE; Grim GP; Hartouni EP; Hatarik R; Moore AS
Rev Sci Instrum; 2018 Oct; 89(10):10I135. PubMed ID: 30399914
[TBL] [Abstract][Full Text] [Related]
15. Comparison of implosion core metrics: A 10 ps dilation X-ray imager vs a 100 ps gated microchannel plate.
Nagel SR; Benedetti LR; Bradley DK; Hilsabeck TJ; Izumi N; Khan S; Kyrala GA; Ma T; Pak A
Rev Sci Instrum; 2016 Nov; 87(11):11E311. PubMed ID: 27910406
[TBL] [Abstract][Full Text] [Related]
16. Restoration of saturated outputs from microchannel plate photomultiplier tubes in sub-microsecond single-pulse-current mode.
Meng S; Yi Q; Zhou L; Yan X; Yang J; Ye F; Yang R; Jiang S; Ning J; Huang Z; Xu Z; Li Z; Lu J
Rev Sci Instrum; 2023 Nov; 94(11):. PubMed ID: 37921519
[TBL] [Abstract][Full Text] [Related]
17. Simulation of the temporal resolution uniformity of a dilation framing camera.
Lin K; Luo Q; Chen J; Wang J; Huang J; Wang D; Liu J; Cai H
Appl Opt; 2022 Nov; 61(31):9107-9111. PubMed ID: 36607043
[TBL] [Abstract][Full Text] [Related]
18.
Schlossberg DJ; Moore AS; Beeman BV; Eckart MJ; Grim GP; Hartouni EP; Hatarik R; Rubery MS; Sayre DB; Waltz C
Rev Sci Instrum; 2018 Oct; 89(10):10I136. PubMed ID: 30399741
[TBL] [Abstract][Full Text] [Related]
19. A 4-GHz frequency-domain fluorometer with internal microchannel plate photomultiplier cross-correlation.
Berndt KW; Gryczynski I; Lakowicz JR
Anal Biochem; 1991 Jan; 192(1):131-7. PubMed ID: 2048714
[TBL] [Abstract][Full Text] [Related]
20. The development of an improved streak tube for fusion diagnostics.
Howorth JR; Milnes JS; Fisher Y; Jadwin A; Boni R; Jaanimagi PA
Rev Sci Instrum; 2016 Nov; 87(11):11D447. PubMed ID: 27910574
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]