BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

977 related articles for article (PubMed ID: 29960755)

  • 1. Impact of Aortic Root Anatomy and Geometry on Paravalvular Leak in Transcatheter Aortic Valve Replacement With Extremely Large Annuli Using the Edwards SAPIEN 3 Valve.
    Tang GHL; Zaid S; George I; Khalique OK; Abramowitz Y; Maeno Y; Makkar RR; Jilaihawi H; Kamioka N; Thourani VH; Babaliaros V; Webb JG; Htun NM; Attinger-Toller A; Ahmad H; Kaple R; Sharma K; Kozina JA; Kaneko T; Shah P; Hirji SA; Desai ND; Anwaruddin S; Jagasia D; Herrmann HC; Basra SS; Szerlip MA; Mack MJ; Mathur M; Tan CW; Don CW; Sharma R; Gafoor S; Zhang M; Kapadia SR; Mick SL; Krishnaswamy A; Amoroso N; Salemi A; Wong SC; Kini AS; Rodés-Cabau J; Leon MB; Kodali SK
    JACC Cardiovasc Interv; 2018 Jul; 11(14):1377-1387. PubMed ID: 29960755
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mid-Term Outcomes of Transcatheter Aortic Valve Replacement in Extremely Large Annuli With Edwards SAPIEN 3 Valve.
    Sengupta A; Zaid S; Kamioka N; Terre J; Miyasaka M; Hirji SA; Hensey M; Geloo N; Petrossian G; Robinson N; Sarin E; Ryan L; Yoon SH; Tan CW; Khalique OK; Kodali SK; Kaneko T; Shah PB; Wong SC; Salemi A; Sharma K; Kozina JA; Szerlip MA; Don CW; Gafoor S; Zhang M; Newhart Z; Kapadia SR; Mick SL; Krishnaswamy A; Kini A; Ahmad H; Lansman SL; Mack MJ; Webb JG; Babaliaros V; Thourani VH; Makkar RR; Leon MB; George I; Tang GHL
    JACC Cardiovasc Interv; 2020 Jan; 13(2):210-216. PubMed ID: 31883715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Overexpansion of the 29 mm SAPIEN 3 transcatheter heart valve in patients with large aortic annuli (area > 683 mm
    Mathur M; McCabe JM; Aldea G; Pal J; Don CW
    Catheter Cardiovasc Interv; 2018 May; 91(6):1149-1156. PubMed ID: 28836337
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bioprosthetic Valve Performance After Transcatheter Aortic Valve Replacement With Self-Expanding Versus Balloon-Expandable Valves in Large Versus Small Aortic Valve Annuli: Insights From the CHOICE Trial and the CHOICE-Extend Registry.
    Abdelghani M; Mankerious N; Allali A; Landt M; Kaur J; Sulimov DS; Merten C; Sachse S; Mehilli J; Neumann FJ; Frerker C; Kurz T; El-Mawardy M; Richardt G; Abdel-Wahab M
    JACC Cardiovasc Interv; 2018 Dec; 11(24):2507-2518. PubMed ID: 30503595
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative Prediction of Paravalvular Leak in Transcatheter Aortic Valve Replacement Based on Tissue-Mimicking 3D Printing.
    Qian Z; Wang K; Liu S; Zhou X; Rajagopal V; Meduri C; Kauten JR; Chang YH; Wu C; Zhang C; Wang B; Vannan MA
    JACC Cardiovasc Imaging; 2017 Jul; 10(7):719-731. PubMed ID: 28683947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Anatomical risk models for paravalvular leak and landing zone complications for balloon-expandable transcatheter aortic valve replacement.
    Condado JF; Corrigan FE; Lerakis S; Parastatidis I; Stillman AE; Binongo JN; Stewart J; Mavromatis K; Devireddy C; Leshnower B; Guyton R; Forcillo J; Patel A; Thourani VH; Block PC; Babaliaros V
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):690-700. PubMed ID: 28471092
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Outcomes of Direct Transcatheter Aortic Valve Replacement Without Balloon Aortic Valvuloplasty Using a New Generation Valve.
    Aalaei-Andabili SH; Beaver TM; Bavry AA; Petersen JW; Karimi A; Wayangankar S; Arnaoutakis G; Anderson RD
    Cardiovasc Revasc Med; 2019 Dec; 20(12):1100-1104. PubMed ID: 30826204
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Third-Generation Balloon and Self-Expandable Valves for Aortic Stenosis in Large and Extra-Large Aortic Annuli From the TAVR-LARGE Registry.
    Armijo G; Tang GHL; Kooistra N; Ferreira-Neto AN; Toggweiler S; Amat-Santos IJ; Keller LS; Urena M; Ahmad H; Tafur Soto J; Muñoz-Garcia E; Regueiro A; Leenders GE; Tirado-Conte G; Sengupta A; McInerney A; Couture T; Cuevas Herreros O; Rodriguez-Gabella T; Kini A; Ahmed M; Zaid S; Gonzalo N; Nuñez-Gil IJ; Muñoz-Garcia AJ; Jimenez-Quevedo P; Fernández-Ortiz A; Himbert D; Nietlispach F; Stella P; Dangas GD; Escaned J; Macaya C; Rodés-Cabau J; Nombela-Franco L
    Circ Cardiovasc Interv; 2020 Aug; 13(8):e009047. PubMed ID: 32757657
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Outcomes of Redo Transcatheter Aortic Valve Replacement for the Treatment of Postprocedural and Late Occurrence of Paravalvular Regurgitation and Transcatheter Valve Failure.
    Barbanti M; Webb JG; Tamburino C; Van Mieghem NM; Makkar RR; Piazza N; Latib A; Sinning JM; Won-Keun K; Bleiziffer S; Bedogni F; Kapadia S; Tchetche D; Rodés-Cabau J; Fiorina C; Nombela-Franco L; De Marco F; de Jaegere PP; Chakravarty T; Vaquerizo B; Colombo A; Svensson L; Lange R; Nickenig G; Möllmann H; Walther T; Della Rosa F; Elhmidi Y; Dvir D; Brambilla N; Immè S; Sgroi C; Gulino S; Todaro D; Pilato G; Petronio AS; Tamburino C
    Circ Cardiovasc Interv; 2016 Sep; 9(9):. PubMed ID: 27578840
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Computed Tomography-Based Oversizing Degrees and Incidence of Paravalvular Regurgitation of a New Generation Transcatheter Heart Valve.
    Blanke P; Pibarot P; Hahn R; Weissman N; Kodali S; Thourani V; Parvataneni R; Dvir D; Naoum C; Nørgaard BL; Douglas P; Jaber W; Khalique OK; Jilaihawi H; Mack M; Smith C; Leon M; Webb J; Leipsic J
    JACC Cardiovasc Interv; 2017 Apr; 10(8):810-820. PubMed ID: 28427598
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic valve and left ventricular outflow tract calcium volume and distribution in transcatheter aortic valve replacement: Influence on the risk of significant paravalvular regurgitation.
    Hansson NC; Leipsic J; Pugliese F; Andersen HR; Rossi A; Simonato M; Jensen KT; Christiansen EH; Terkelsen CJ; Blanke P; Tang M; Krusell LR; Klaaborg KE; Terp K; Kennon S; Dvir D; Bøtker HE; Webb J; Nørgaard BL
    J Cardiovasc Comput Tomogr; 2018; 12(4):290-297. PubMed ID: 29519754
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 3-Dimensional printing to predict paravalvular regurgitation after transcatheter aortic valve replacement.
    Reiff C; Zhingre Sanchez JD; Mattison LM; Iaizzo PA; Garcia S; Raveendran G; Gurevich S
    Catheter Cardiovasc Interv; 2020 Dec; 96(7):E703-E710. PubMed ID: 32077222
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Risk factors for paravalvular leak after transcatheter aortic valve replacement.
    Pollari F; Dell'Aquila AM; Söhn C; Marianowicz J; Wiehofsky P; Schwab J; Pauschinger M; Hitzl W; Fischlein T; Pfeiffer S
    J Thorac Cardiovasc Surg; 2019 Apr; 157(4):1406-1415.e3. PubMed ID: 30482527
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Novel predictors of mild paravalvular aortic regurgitation in SAPIEN 3 transcatheter aortic valve implantation.
    Tang GHL; Zaid S; Schnittman SR; Ahmad H; Kaple R; Undemir C; Dutta T; Poniros A; Bennett J; Feng C; Cohen M; Lansman SL
    EuroIntervention; 2018 May; 14(1):58-68. PubMed ID: 29488887
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Replacement With the SAPIEN 3.
    Mauri V; Reimann A; Stern D; Scherner M; Kuhn E; Rudolph V; Rosenkranz S; Eghbalzadeh K; Friedrichs K; Wahlers T; Baldus S; Madershahian N; Rudolph TK
    JACC Cardiovasc Interv; 2016 Nov; 9(21):2200-2209. PubMed ID: 27832845
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of transcatheter valves for aortic valve replacement in pediatric patients: A case series.
    Sinha S; Khan A; Qureshi AM; Suh W; Laks H; Aboulhosn J; Biniwale R; Adachi I; Fernando A; Levi D
    Catheter Cardiovasc Interv; 2020 Feb; 95(2):253-261. PubMed ID: 31609055
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Optimal positioning of self-expanding valves before deployment decreases paravalvular regurgitation following transcatheter aortic valve replacement.
    Dadu RT; Xu J; Rehman H; von Ballmoos MW; Barker CM; Reyes M; Ramchandani M; Reul RM; Reardon MJ; Kleiman NS
    Catheter Cardiovasc Interv; 2019 Jan; 93(1):149-155. PubMed ID: 30218488
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Pre-procedural fit-testing of TAVR valves using parametric modeling and 3D printing.
    Hosny A; Dilley JD; Kelil T; Mathur M; Dean MN; Weaver JC; Ripley B
    J Cardiovasc Comput Tomogr; 2019; 13(1):21-30. PubMed ID: 30322772
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Initial Experience of a Second-Generation Self-Expanding Transcatheter Aortic Valve: The UK & Ireland Evolut R Implanters' Registry.
    Kalra SS; Firoozi S; Yeh J; Blackman DJ; Rashid S; Davies S; Moat N; Dalby M; Kabir T; Khogali SS; Anderson RA; Groves PH; Mylotte D; Hildick-Smith D; Rampat R; Kovac J; Gunarathne A; Laborde JC; Brecker SJ
    JACC Cardiovasc Interv; 2017 Feb; 10(3):276-282. PubMed ID: 28183467
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The Effect of Post-Dilatation on Outcomes in the PARTNER 2 SAPIEN 3 Registry.
    Hahn RT; Pibarot P; Leipsic J; Blanke P; Douglas PS; Weissman NJ; Kapadia S; Thourani VH; Herrmann HC; Nazif T; McAndrew T; Webb JG; Leon MB; Kodali S
    JACC Cardiovasc Interv; 2018 Sep; 11(17):1710-1718. PubMed ID: 30121276
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 49.