These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
110 related articles for article (PubMed ID: 29980961)
1. Inappropriate shock from myopotentials due to subcutaneous defibrillator (S-ICD) movement confirmed on fluoroscopy with subsequent device pocket revision. Chieng D; Stewart B; Paul V J Interv Card Electrophysiol; 2018 Nov; 53(2):263-265. PubMed ID: 29980961 [No Abstract] [Full Text] [Related]
2. Subcutaneous Implantable Cardioverter Defibrillator Lead Repositioning for Preventing Inappropriate Shocks Due to Myopotential Oversensing in a Post-Fulminant Myocarditis Patient. Sasaki T; Nakamura K; Naito S Int Heart J; 2019 Mar; 60(2):466-469. PubMed ID: 30745542 [TBL] [Abstract][Full Text] [Related]
3. Long-term incidence of inappropriate shocks in patients with implantable cardioverter defibrillators in clinical practice-an underestimated complication? Hofer D; Steffel J; Hürlimann D; Haegeli L; Lüscher TF; Duru F; Eriksson U; Krasniqi N J Interv Card Electrophysiol; 2017 Dec; 50(3):219-226. PubMed ID: 29177981 [TBL] [Abstract][Full Text] [Related]
4. Inappropriate shock for myopotential over-sensing in a patient with subcutaneous ICD. Corzani A; Ziacchi M; Biffi M; Diemberger I; Martignani C; Boriani G Indian Heart J; 2015; 67(1):56-9. PubMed ID: 25820052 [TBL] [Abstract][Full Text] [Related]
5. S-ICD lead dislodgement in a young isometric athlete: A rare complication. Bissolino A; Andreis A; Magnano M; Budano C; Castagno D; Golzio PG; Giustetto C; De Ferrari GM Pacing Clin Electrophysiol; 2020 Aug; 43(8):898-900. PubMed ID: 32460376 [TBL] [Abstract][Full Text] [Related]
6. Device complications and inappropriate implantable cardioverter defibrillator shocks in patients with hypertrophic cardiomyopathy. Lin G; Nishimura RA; Gersh BJ; Phil D; Ommen SR; Ackerman MJ; Brady PA Heart; 2009 May; 95(9):709-14. PubMed ID: 19282314 [TBL] [Abstract][Full Text] [Related]
7. Inappropriate shock due to late dislocation of electrode. Ruiz-Salas A; Datino T; Peña-Hernández J; Calvo D; Alzueta J Int J Cardiol; 2015 Nov; 199():229-31. PubMed ID: 26209824 [No Abstract] [Full Text] [Related]
8. [ICD inappropriate shock for atrial fibrillation: use of home-monitoring for the prevention]. Amara W Ann Cardiol Angeiol (Paris); 2014 Nov; 63(5):389-93. PubMed ID: 25240744 [TBL] [Abstract][Full Text] [Related]
9. [Inappropriate therapy of an implantable cardioverter-defibrillator--is it always an undesired event? A case report]. Krzyzanowski K; Michałkiewicz D; Wierzbowski R; Gniłka A; Ryczek R; Orski Z; Kubik L Kardiol Pol; 2009 Aug; 67(8):927-9. PubMed ID: 19784895 [TBL] [Abstract][Full Text] [Related]
10. Acute and Long-term Results After Contemporary Subcutaneous Implantable Cardioverter-defibrillator Implantation: A Single-center Experience. Arias MA; Pachón M; Akerström F; Puchol A; Martín-Sierra C; Rodríguez-Padial L Rev Esp Cardiol (Engl Ed); 2018 Nov; 71(11):895-901. PubMed ID: 29221700 [TBL] [Abstract][Full Text] [Related]
11. The Dx-AF study: a prospective, multicenter, randomized controlled trial comparing VDD-ICD to VVI-ICD in detecting sub-clinical atrial fibrillation in defibrillator patients. Shurrab M; Janmohamed A; Sarrazin JF; Ayala-Paredes F; Sturmer M; Williams R; Toal S; Lane C; Thorpe KE; Healey JS; Crystal E J Interv Card Electrophysiol; 2017 Oct; 50(1):57-63. PubMed ID: 28752228 [TBL] [Abstract][Full Text] [Related]
12. Subcutaneous implantable cardioverter-defibrillator: First single-center experience with other cardiac implantable electronic devices. Kuschyk J; Stach K; Tülümen E; Rudic B; Liebe V; Schimpf R; Borggrefe M; Röger S Heart Rhythm; 2015 Nov; 12(11):2230-8. PubMed ID: 26073595 [TBL] [Abstract][Full Text] [Related]
13. Inhibition of bradycardia pacing and detection of ventricular fibrillation due to far-field atrial sensing in a triple chamber implantable cardioverter defibrillator. Vollmann D; Lüthje L; Görtler G; Unterberg C Pacing Clin Electrophysiol; 2002 Oct; 25(10):1513-6. PubMed ID: 12418750 [TBL] [Abstract][Full Text] [Related]
14. Implantable cardiac defibrillator lead failure or myopotential oversensing? An approach to the diagnosis of noise on lead electrograms. Kowalski M; Ellenbogen KA; Wood MA; Friedman PL Europace; 2008 Aug; 10(8):914-7. PubMed ID: 18565976 [TBL] [Abstract][Full Text] [Related]
15. Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience. Weinstock J; Bader YH; Maron MS; Rowin EJ; Link MS J Am Heart Assoc; 2016 Feb; 5(2):. PubMed ID: 26873684 [TBL] [Abstract][Full Text] [Related]
16. Association between ventricular pacing and persistent atrial fibrillation in patients indicated to elective pacemaker replacement: Results of the Prefer for Elective Replacement MVP (PreFER MVP) randomized study. Ricci RP; Botto GL; Bénézet JM; Nielsen JC; De Roy L; Piot O; Quesada A; Quaglione R; Vaccari D; Mangoni L; Grammatico A; Kozák M; Heart Rhythm; 2015 Nov; 12(11):2239-46. PubMed ID: 26142300 [TBL] [Abstract][Full Text] [Related]