BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

345 related articles for article (PubMed ID: 29982361)

  • 1. Comparative Accuracy of Bowel Ultrasound Versus Magnetic Resonance Enterography in Combination With Colonoscopy in Assessing Crohn's Disease and Guiding Clinical Decision-making.
    Allocca M; Fiorino G; Bonifacio C; Furfaro F; Gilardi D; Argollo M; Peyrin-Biroulet L; Danese S
    J Crohns Colitis; 2018 Nov; 12(11):1280-1287. PubMed ID: 29982361
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Prevalence of Bowel Damage Assessed by Cross-Sectional Imaging in Early Crohn's Disease and its Impact on Disease Outcome.
    Fiorino G; Morin M; Bonovas S; Bonifacio C; Spinelli A; Germain A; Laurent V; Zallot C; Peyrin-Biroulet L; Danese S
    J Crohns Colitis; 2017 Mar; 11(3):274-280. PubMed ID: 27799269
    [TBL] [Abstract][Full Text] [Related]  

  • 3. David Against Goliath: Direct Comparison of Handheld Bowel Sonography and Magnetic Resonance Enterography for Diagnosis of Crohn's Disease.
    Rispo A; de Sire R; Mainenti PP; Imperatore N; Testa A; Maurea S; Ricciolino S; Nardone OM; Olmo O; Castiglione F
    Inflamm Bowel Dis; 2023 Apr; 29(4):563-569. PubMed ID: 35666249
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Intra-Abdominal Adhesions Make the Interpretation of Magnetic Resonance Enterography in Crohn's Disease More Difficult.
    Aaltonen G; Keränen I; Carpelan-Holmström M; Savolainen R; Lindén R; Lepistö A
    Dig Surg; 2017; 34(1):30-35. PubMed ID: 27384313
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intra-Cavitary Contrast-Enhanced Ultrasound: A Novel Radiation-Free Method for Detecting Abscess-Associated Penetrating Disease in Crohn's Disease.
    Mao R; Chen YJ; Chen BL; Xie XH; He Y; Chen SL; Xu M; Li XH; Zhang J; Song XM; Zeng ZR; Rimola J; Rieder F; Ben-Horin S; Chen MH; Xie XY
    J Crohns Colitis; 2019 Apr; 13(5):593-599. PubMed ID: 30544185
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Magnetic resonance enterography compared with ultrasonography in newly diagnosed and relapsing Crohn's disease patients: the METRIC diagnostic accuracy study.
    Taylor SA; Mallett S; Bhatnagar G; Morris S; Quinn L; Tomini F; Miles A; Baldwin-Cleland R; Bloom S; Gupta A; Hamlin PJ; Hart AL; Higginson A; Jacobs I; McCartney S; Murray CD; Plumb AA; Pollok RC; Rodriguez-Justo M; Shabir Z; Slater A; Tolan D; Travis S; Windsor A; Wylie P; Zealley I; Halligan S
    Health Technol Assess; 2019 Aug; 23(42):1-162. PubMed ID: 31432777
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ultrasonographic detection of intestinal complications in Crohn's disease.
    Maconi G; Bollani S; Bianchi Porro G
    Dig Dis Sci; 1996 Aug; 41(8):1643-8. PubMed ID: 8769293
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Contrast radiology, computed tomography and ultrasonography in detecting internal fistulas and intra-abdominal abscesses in Crohn's disease: a prospective comparative study.
    Maconi G; Sampietro GM; Parente F; Pompili G; Russo A; Cristaldi M; Arborio G; Ardizzone S; Matacena G; Taschieri AM; Bianchi Porro G
    Am J Gastroenterol; 2003 Jul; 98(7):1545-55. PubMed ID: 12873576
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Small intestinal contrast ultrasonography for the detection of small bowel complications in Crohn's disease: correlation with intraoperative findings and magnetic resonance enterography.
    Kumar S; Hakim A; Alexakis C; Chhaya V; Tzias D; Pilcher J; Vlahos J; Pollok R
    J Gastroenterol Hepatol; 2015 Jan; 30(1):86-91. PubMed ID: 25168482
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Prospective comparison of computed tomography enterography and magnetic resonance enterography for assessment of disease activity and complications in ileocolonic Crohn's disease.
    Fiorino G; Bonifacio C; Peyrin-Biroulet L; Minuti F; Repici A; Spinelli A; Fries W; Balzarini L; Montorsi M; Malesci A; Danese S
    Inflamm Bowel Dis; 2011 May; 17(5):1073-80. PubMed ID: 21484958
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A Fixed Stricture on Routine Cross-sectional Imaging Predicts Disease-Related Complications and Adverse Outcomes in Patients with Crohn's Disease.
    Chaudhry NA; Riverso M; Grajo JR; Moser PP; Zou F; Homsi M; Punglia DR; Zimmermann EM
    Inflamm Bowel Dis; 2017 Apr; 23(4):641-649. PubMed ID: 28267043
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Main Imaging Features of Crohn's Disease: Agreement between MR-Enterography and CT-Enterography.
    Amitai MM; Raviv-Zilka L; Hertz M; Erlich Z; Konen E; Ben-Horin S; Apter S
    Isr Med Assoc J; 2015 May; 17(5):293-7. PubMed ID: 26137655
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Colon capsule endoscopy compared with other modalities in the evaluation of pediatric Crohn's disease of the small bowel and colon.
    Oliva S; Cucchiara S; Civitelli F; Casciani E; Di Nardo G; Hassan C; Papoff P; Cohen SA
    Gastrointest Endosc; 2016 May; 83(5):975-83. PubMed ID: 26363334
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of CT enterography and magnetic resonance enterography imaging to detect lesions preoperatively in patients undergoing surgery for Crohn's disease.
    Seastedt KP; Trencheva K; Michelassi F; Alsaleh D; Milsom JW; Sonoda T; Lee SW; Nandakumar G
    Dis Colon Rectum; 2014 Dec; 57(12):1364-70. PubMed ID: 25380001
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correlation between magnetic resonance enterography and ileo-colonoscopy for assessment of disease activity in terminal ileal Crohn's disease.
    Kakkar C; Singh A; Mahajan R; Midha V; Goyal S; Narang V; Gupta K; Singh D; Bansal N; Saggar K; Sood A
    Indian J Gastroenterol; 2022 Oct; 41(5):465-474. PubMed ID: 36357600
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Impact of high-resolution transabdominal ultrasound in the diagnosis of complications of Crohn's disease.
    Neye H; Ensberg D; Rauh P; Peitz U; Mönkemüller K; Treiber G; Klauck S; Malfertheiner P; Rickes S
    Scand J Gastroenterol; 2010 Jun; 45(6):690-5. PubMed ID: 20235899
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Utility of bowel ultrasound in assessing disease activity in Crohn's disease.
    Kakkadasam Ramaswamy P; Vizhi N K; Yelsangikar A; Krishnamurthy AN; Bhat V; Bhat N
    Indian J Gastroenterol; 2020 Oct; 39(5):495-502. PubMed ID: 33201441
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnostic accuracy of intestinal ultrasound and magnetic resonance enterography for the detection of endoscopy-based disease activity in ileocolonic Crohn's disease.
    Yuksel I; Kilincalp S; Coskun Y; Akinci H; Hamamci M; Alkan A
    Eur J Gastroenterol Hepatol; 2019 Jul; 31(7):809-816. PubMed ID: 31094855
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Interobserver and intermodality agreement for detection of small bowel Crohn's disease with MR enterography and CT enterography.
    Jensen MD; Ormstrup T; Vagn-Hansen C; Østergaard L; Rafaelsen SR
    Inflamm Bowel Dis; 2011 May; 17(5):1081-8. PubMed ID: 21484959
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transabdominal bowel sonography for the detection of intestinal complications in Crohn's disease.
    Gasche C; Moser G; Turetschek K; Schober E; Moeschl P; Oberhuber G
    Gut; 1999 Jan; 44(1):112-7. PubMed ID: 9862836
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 18.