These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

164 related articles for article (PubMed ID: 29984254)

  • 1. Biomechanical Characteristics of Three Baseplate Rotational Arrangement Techniques in Total Knee Arthroplasty.
    Kang K; Jang YW; Yoo OS; Jung D; Lee SJ; Lee MC; Lim D
    Biomed Res Int; 2018; 2018():9641417. PubMed ID: 29984254
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Undersizing the Tibial Baseplate in Cementless Total Knee Arthroplasty has Only a Small Impact on Bone-Implant Interaction: A Finite Element Biomechanical Study.
    Quevedo González FJ; Sculco PK; Kahlenberg CA; Mayman DJ; Lipman JD; Wright TM; Vigdorchik JM
    J Arthroplasty; 2023 Apr; 38(4):757-762. PubMed ID: 36280162
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Curve-on-curve technique does not improve tibial coverage in total knee arthroplasty in comparison to tibial tuberosity technique with use of anatomical implants: randomized controlled trial.
    Maciąg BM; Kordyaczny T; Żarnovsky K; Budzińska M; Jegierski D; Łapiński M; Maciąg GJ; Stolarczyk A
    Arch Orthop Trauma Surg; 2023 Sep; 143(9):5901-5907. PubMed ID: 37000268
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The original Akagi line is the most reliable: a systematic review of landmarks for rotational alignment of the tibial component in TKA.
    Saffarini M; Nover L; Tandogan R; Becker R; Moser LB; Hirschmann MT; Indelli PF
    Knee Surg Sports Traumatol Arthrosc; 2019 Apr; 27(4):1018-1027. PubMed ID: 30203197
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A Best-Fit of an Anatomic Tibial Baseplate Closely Parallels the Flexion-Extension Plane and Covers a High Percentage of the Proximal Tibia.
    Nedopil AJ; Zamora T; Shelton T; Howell SM; Hull M
    J Knee Surg; 2021 Nov; 34(13):1486-1494. PubMed ID: 32403149
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Finite-Element analysis of a lateral femoro-tibial impact on the total knee arthroplasty.
    Arab AZE; Merdji A; Benaissa A; Roy S; Bachir Bouiadjra BA; Layadi K; Ouddane A; Mukdadi OM
    Comput Methods Programs Biomed; 2020 Aug; 192():105446. PubMed ID: 32200048
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Rotational positioning of the tibial tray in total knee arthroplasty: a CT evaluation.
    Berhouet J; Beaufils P; Boisrenoult P; Frasca D; Pujol N
    Orthop Traumatol Surg Res; 2011 Nov; 97(7):699-704. PubMed ID: 21993150
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Impact of Tibial Component Coronal Alignment on Knee Joint Biomechanics Following Fixed-bearing Unicompartmental Knee Arthroplasty: A Finite Element Analysis.
    Nie Y; Yu Q; Shen B
    Orthop Surg; 2021 Jun; 13(4):1423-1429. PubMed ID: 34018326
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of tibial baseplate malposition on kinematics, contact forces and ligament tensions in TKA: A numerical analysis.
    Fottner A; Woiczinski M; Schröder C; Schmidutz F; Weber P; Müller PE; Jansson V; Steinbrück A
    J Mech Behav Biomed Mater; 2020 Mar; 103():103564. PubMed ID: 32090954
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of mediolateral tibial baseplate position in TKA on knee kinematics and retropatellar pressure.
    Steinbrück A; Fottner A; Schröder C; Woiczinski M; Schmitt-Sody M; Müller T; Müller PE; Jansson V
    Knee Surg Sports Traumatol Arthrosc; 2017 Aug; 25(8):2602-2608. PubMed ID: 26531185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Prosthesis alignment affects axial rotation motion after total knee replacement: a prospective in vivo study combining computed tomography and fluoroscopic evaluations.
    Harman MK; Banks SA; Kirschner S; Lützner J
    BMC Musculoskelet Disord; 2012 Oct; 13():206. PubMed ID: 23088451
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Small differences in tibial contact locations following kinematically aligned TKA from the native contralateral knee.
    Nicolet-Petersen S; Saiz A; Shelton T; Howell SM; Hull ML
    Knee Surg Sports Traumatol Arthrosc; 2020 Sep; 28(9):2893-2904. PubMed ID: 31410525
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Current Total Knee Designs: Does Baseplate Roughness or Locking Mechanism Design Affect Polyethylene Backside Wear?
    Sisko ZW; Teeter MG; Lanting BA; Howard JL; McCalden RW; Naudie DD; MacDonald SJ; Vasarhelyi EM
    Clin Orthop Relat Res; 2017 Dec; 475(12):2970-2980. PubMed ID: 28905208
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Population-based effect of total knee arthroplasty alignment on simulated tibial bone remodeling.
    Anijs T; Wolfson D; Verdonschot N; Janssen D
    J Mech Behav Biomed Mater; 2020 Nov; 111():104014. PubMed ID: 32810653
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Loosening of tibia baseplates after total knee arthroplasty: Evaluation of pull-out strength of tibia baseplate-cement Interface.
    Rebgetz P; Kovacs A; Bochat K; Hayes A; Clark G; Blakeney W; Pabbruwe M
    Clin Biomech (Bristol, Avon); 2021 Dec; 90():105497. PubMed ID: 34619452
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Analysis of the tibial baseplate coverage and symmetrical tibial prosthesis in primary total knee arthroplasty].
    Zhao CL; Wang JP; Sun ZH; Li M; Chen JW
    Zhonghua Yi Xue Za Zhi; 2017 Nov; 97(41):3225-3229. PubMed ID: 29141359
    [No Abstract]   [Full Text] [Related]  

  • 17. Various Types of Medial Tibial Bone Resorption after Total Knee Arthroplasty Using a Thick Cobalt Chromium Tibial Baseplate.
    Song SJ; Lee HW; Kang SG; Bae DK; Park CH
    J Knee Surg; 2022 Mar; 35(4):434-442. PubMed ID: 32838461
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Partially loaded plain radiographic measurement to evaluate rotational alignment in total knee arthroplasty.
    Pedraza W; Beckmann J; Mayer C; Mauch F; Huth J; Best R
    Int Orthop; 2016 Dec; 40(12):2519-2526. PubMed ID: 27447464
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design.
    Dong Y; Zhang Z; Dong W; Hu G; Wang B; Mou Z
    BMC Musculoskelet Disord; 2020 Mar; 21(1):165. PubMed ID: 32164625
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Anterior tibial curved cortex is a reliable landmark for tibial rotational alignment in total knee arthroplasty.
    Kim JI; Jang J; Lee KW; Han HS; Lee S; Lee MC
    BMC Musculoskelet Disord; 2017 Jun; 18(1):252. PubMed ID: 28606122
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.