These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 29993541)
1. Effect of Model Thrombus Volume and Elastic Modulus on Magnetomotive Ultrasound Signal Under Pulsatile Flow. Levy BE; Hossain MM; Sierchio JM; Thapa D; Gallippi CM; Oldenburg AL IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Aug; 65(8):1380-1388. PubMed ID: 29993541 [TBL] [Abstract][Full Text] [Related]
2. Inversion of displacement fields to quantify the magnetic particle distribution in homogeneous elastic media from magnetomotive ultrasound. Thapa D; Levy BE; Marks DL; Oldenburg AL Phys Med Biol; 2019 Jun; 64(12):125019. PubMed ID: 31051477 [TBL] [Abstract][Full Text] [Related]
3. Elastometry of clot phantoms via magnetomotive ultrasound-based resonant acoustic spectroscopy. Levy BE; Oldenburg AL Phys Med Biol; 2022 Jul; 67(15):. PubMed ID: 35790176 [No Abstract] [Full Text] [Related]
4. Blind Source Separation-Based Motion Detector for Imaging Super-Paramagnetic Iron Oxide (SPIO) Particles in Magnetomotive Ultrasound Imaging. Hossain MM; Levy BE; Thapa D; Oldenburg AL; Gallippi CM IEEE Trans Med Imaging; 2018 Oct; 37(10):2356-2366. PubMed ID: 29994656 [TBL] [Abstract][Full Text] [Related]
5. Combined Magnetomotive ultrasound, PET/CT, and MR imaging of Evertsson M; Kjellman P; Cinthio M; Andersson R; Tran TA; In't Zandt R; Grafström G; Toftevall H; Fredriksson S; Ingvar C; Strand SE; Jansson T Sci Rep; 2017 Jul; 7(1):4824. PubMed ID: 28684867 [TBL] [Abstract][Full Text] [Related]
6. On the Performance of Time Domain Displacement Estimators for Magnetomotive Ultrasound Imaging. Ersepke T; Kranemann TC; Schmitz G IEEE Trans Ultrason Ferroelectr Freq Control; 2019 May; 66(5):911-921. PubMed ID: 30869613 [TBL] [Abstract][Full Text] [Related]
7. Pulsatile flow characterization in a vessel phantom with elastic wall using ultrasonic particle image velocimetry technique: the impact of vessel stiffness on flow dynamics. Qian M; Niu L; Wong KK; Abbott D; Zhou Q; Zheng H IEEE Trans Biomed Eng; 2014 Sep; 61(9):2444-50. PubMed ID: 24801192 [TBL] [Abstract][Full Text] [Related]
8. Elastic and acoustic properties of vessel mimicking material for elasticity imaging. de Korte CL; Céspedes EI; van der Steen AF; Norder B; te Nijenhuis K Ultrason Imaging; 1997 Apr; 19(2):112-26. PubMed ID: 9381628 [TBL] [Abstract][Full Text] [Related]
9. Experimental foundation for in vivo measurement of the elasticity of the aorta in computed tomography angiography. Schlicht MS; Khanafer K; Duprey A; Cronin P; Berguer R Eur J Vasc Endovasc Surg; 2013 Oct; 46(4):447-52. PubMed ID: 23932205 [TBL] [Abstract][Full Text] [Related]
10. Single Magnetic Particle Motion in Magnetomotive Ultrasound: An Analytical Model and Experimental Validation. Levy BE; Oldenburg AL IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Aug; 68(8):2635-2644. PubMed ID: 33844629 [TBL] [Abstract][Full Text] [Related]
11. A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate. Swillens A; Degroote J; Vierendeels J; Lovstakken L; Segers P Med Phys; 2010 Aug; 37(8):4318-30. PubMed ID: 20879592 [TBL] [Abstract][Full Text] [Related]
12. Contrast-enhanced imaging of SPIO-labeled platelets using magnetomotive ultrasound. Pope AG; Wu G; McWhorter FY; Merricks EP; Nichols TC; Czernuszewicz TJ; Gallippi CM; Oldenburg AL Phys Med Biol; 2013 Oct; 58(20):7277-90. PubMed ID: 24077004 [TBL] [Abstract][Full Text] [Related]
13. Frequency- and phase-sensitive magnetomotive ultrasound imaging of superparamagnetic iron oxide nanoparticles. Evertsson M; Cinthio M; Fredriksson S; Olsson F; Persson H; Jansson T IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Mar; 60(3):481-91. PubMed ID: 23475915 [TBL] [Abstract][Full Text] [Related]
14. Shear elastic modulus estimation from indentation and SDUV on gelatin phantoms. Amador C; Urban MW; Chen S; Chen Q; An KN; Greenleaf JF IEEE Trans Biomed Eng; 2011 Jun; 58(6):1706-14. PubMed ID: 21317078 [TBL] [Abstract][Full Text] [Related]
15. Time-dependent hardening of blood clots quantitatively measured in vivo with shear-wave ultrasound imaging in a rabbit model of venous thrombosis. Mfoumou E; Tripette J; Blostein M; Cloutier G Thromb Res; 2014 Feb; 133(2):265-71. PubMed ID: 24315316 [TBL] [Abstract][Full Text] [Related]
16. Multimodal detection of iron oxide nanoparticles in rat lymph nodes using magnetomotive ultrasound imaging and magnetic resonance imaging. Evertsson M; Kjellman P; Cinthio M; Fredriksson S; in't Zandt R; Persson H; Jansson T IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Aug; 61(8):1276-83. PubMed ID: 25073135 [TBL] [Abstract][Full Text] [Related]
18. Comparison between shear wave dispersion magneto motive ultrasound and transient elastography for measuring tissue-mimicking phantom viscoelasticity. Almeida TW; Sampaio DR; Bruno AC; Pavan TZ; Carneiro AA IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Dec; 62(12):2138-45. PubMed ID: 26670853 [TBL] [Abstract][Full Text] [Related]
19. Quantitative Determination of Local Density of Iron Oxide Nanoparticles Used for Drug Targeting Employing Inverse Magnetomotive Ultrasound. Fink M; Rupitsch SJ; Lyer S; Ermert H IEEE Trans Ultrason Ferroelectr Freq Control; 2021 Jul; 68(7):2482-2495. PubMed ID: 33760734 [TBL] [Abstract][Full Text] [Related]
20. Vascular elasticity from regional displacement estimates. Mai JJ; Lupotti FA; Insana MF Ultrason Imaging; 2003 Jul; 25(3):171-92. PubMed ID: 14870802 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]