These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 29994636)

  • 1. A Psychophysical Evaluation of Texture Compression Masking Effects.
    Lavoue G; Langer M; Peytavie A; Poulin P
    IEEE Trans Vis Comput Graph; 2019 Feb; 25(2):1336-1346. PubMed ID: 29994636
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluating Texture Compression Masking Effects Using Objective Image Quality Assessment Metrics.
    Griffin W; Olano M
    IEEE Trans Vis Comput Graph; 2015 Aug; 21(8):970-9. PubMed ID: 26357259
    [TBL] [Abstract][Full Text] [Related]  

  • 3. High-dynamic-range texture compression for rendering systems of different capacities.
    Sun W; Lu Y; Wu F; Li S; Tardif J
    IEEE Trans Vis Comput Graph; 2010; 16(1):57-69. PubMed ID: 19910661
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A joint source-channel distortion model for JPEG compressed images.
    Sabir MF; Sheikh HR; Heath RW; Bovik AC
    IEEE Trans Image Process; 2006 Jun; 15(6):1349-64. PubMed ID: 16764262
    [TBL] [Abstract][Full Text] [Related]  

  • 5. JPEG2000 3D compression vs. 2D compression: an assessment of artifact amount and computing time in compressing thin-section abdomen CT images.
    Kim B; Lee KH; Kim KJ; Richter T; Kang HS; Kim SY; Kim YH; Seo J
    Med Phys; 2009 Mar; 36(3):835-44. PubMed ID: 19378744
    [TBL] [Abstract][Full Text] [Related]  

  • 6. JPEG2000 encoding with perceptual distortion control.
    Liu Z; Karam LJ; Watson AB
    IEEE Trans Image Process; 2006 Jul; 15(7):1763-78. PubMed ID: 16830900
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Invariant texture perception is harder with synthetic textures: Implications for models of texture processing.
    Balas B; Conlin C
    Vision Res; 2015 Oct; 115(Pt B):271-9. PubMed ID: 25668773
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Visual perception of procedural textures: identifying perceptual dimensions and predicting generation models.
    Liu J; Dong J; Cai X; Qi L; Chantler M
    PLoS One; 2015; 10(6):e0130335. PubMed ID: 26106895
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Noise-resistant fitting for spherical harmonics.
    Lam PM; Leung CS; Wong TT
    IEEE Trans Vis Comput Graph; 2006; 12(2):254-65. PubMed ID: 16509384
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Artifacts in slab average-intensity-projection images reformatted from JPEG 2000 compressed thin-section abdominal CT data sets.
    Kim B; Lee KH; Kim KJ; Mantiuk R; Kim HR; Kim YH
    AJR Am J Roentgenol; 2008 Jun; 190(6):W342-50. PubMed ID: 18492876
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Advantage in image fidelity and additional computing time of JPEG2000 3D in comparison to JPEG2000 in compressing abdomen CT image datasets of different section thicknesses.
    Lee H; Lee KH; Kim KJ; Park S; Seo J; Shin YG; Kim B
    Med Phys; 2010 Aug; 37(8):4238-48. PubMed ID: 20879584
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Prediction of perceptible artifacts in JPEG 2000-compressed chest CT images using mathematical and perceptual quality metrics.
    Kim B; Lee KH; Kim KJ; Mantiuk R; Hahn S; Kim TJ; Kim YH
    AJR Am J Roentgenol; 2008 Feb; 190(2):328-34. PubMed ID: 18212217
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Using a visual discrimination model for the detection of compression artifacts in virtual pathology images.
    Johnson JP; Krupinski EA; Yan M; Roehrig H; Graham AR; Weinstein RS
    IEEE Trans Med Imaging; 2011 Feb; 30(2):306-14. PubMed ID: 20875970
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prediction of perceptible artifacts in JPEG2000 compressed abdomen CT images using a perceptual image quality metric.
    Kim B; Lee KH; Kim KJ; Mantiuk R; Bajpai V; Kim TJ; Kim YH; Yoon CJ; Hahn S
    Acad Radiol; 2008 Mar; 15(3):314-25. PubMed ID: 18280929
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bit allocation algorithm with novel view synthesis distortion model for multiview video plus depth coding.
    Chung TY; Sim JY; Kim CS
    IEEE Trans Image Process; 2014 Aug; 23(8):3254-67. PubMed ID: 24960105
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Regional difference in compression artifacts in low-dose chest CT images: effects of mathematical and perceptual factors.
    Kim KJ; Kim B; Lee KH; Kim TJ; Mantiuk R; Kang HS; Kim YH
    AJR Am J Roentgenol; 2008 Aug; 191(2):W30-7. PubMed ID: 18647883
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Task-based model/human observer evaluation of SPIHT wavelet compression with human visual system-based quantization.
    Zhang Y; Pham BT; Eckstein MP
    Acad Radiol; 2005 Mar; 12(3):324-36. PubMed ID: 15766693
    [TBL] [Abstract][Full Text] [Related]  

  • 18. 3D DCT Based Image Compression Method for the Medical Endoscopic Application.
    Xue J; Yin L; Lan Z; Long M; Li G; Wang Z; Xie X
    Sensors (Basel); 2021 Mar; 21(5):. PubMed ID: 33807805
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Restoration of lossy compressed noisy images.
    Al-Shaykh OK; Mersereau RM
    IEEE Trans Image Process; 1999; 8(10):1348-60. PubMed ID: 18267407
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Characterization of the spatial-frequency spectrum in the perception of shape from texture.
    Sakai K; Finkel LH
    J Opt Soc Am A Opt Image Sci Vis; 1995 Jun; 12(6):1208-24. PubMed ID: 7769507
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.