These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. Accelerator-based X-ray sources: synchrotron radiation, X-ray free electron lasers and beyond. Ishikawa T Philos Trans A Math Phys Eng Sci; 2019 Jun; 377(2147):20180231. PubMed ID: 31030654 [TBL] [Abstract][Full Text] [Related]
4. Development and assessment of a multi-beam continuous-phantom-motion x-ray scatter projection imaging system. Dydula C; Belev G; Johns PC Rev Sci Instrum; 2019 Mar; 90(3):035104. PubMed ID: 30927807 [TBL] [Abstract][Full Text] [Related]
5. Fourier-Transform Ghost Imaging with Hard X Rays. Yu H; Lu R; Han S; Xie H; Du G; Xiao T; Zhu D Phys Rev Lett; 2016 Sep; 117(11):113901. PubMed ID: 27661686 [TBL] [Abstract][Full Text] [Related]
6. Light output measurements and computational models of microcolumnar CsI scintillators for x-ray imaging. Nillius P; Klamra W; Sibczynski P; Sharma D; Danielsson M; Badano A Med Phys; 2015 Feb; 42(2):600-605. PubMed ID: 28102604 [TBL] [Abstract][Full Text] [Related]
7. Chaotic dynamics in X-ray free-electron lasers with an optical undulator. Abbasi E; Jafari S Sci Rep; 2024 Jan; 14(1):1341. PubMed ID: 38228742 [TBL] [Abstract][Full Text] [Related]
8. Small-gap insertion-device development at the National Synchrotron Light Source--performance of the new X13 mini-gap undulator. Ablett JM; Berman LE; Kao CC; Rakowsky G; Lynch D J Synchrotron Radiat; 2004 Mar; 11(Pt 2):129-31. PubMed ID: 14960776 [TBL] [Abstract][Full Text] [Related]
9. Optimization of radiography applications using x-ray beams emitted by compact accelerators. Part I. Monte Carlo study of the hard x-ray spectrum. Marziani M; Taibi A; Di Domenico G; Gambaccini M Med Phys; 2009 Oct; 36(10):4683-701. PubMed ID: 19928100 [TBL] [Abstract][Full Text] [Related]
10. Synchrotron-based x ray fluorescence ghost imaging. Manni M; Ben-Yehuda A; Klein Y; Lukic B; Kingston A; Rack A; Shwartz S; Viganò N Opt Lett; 2023 Dec; 48(23):6271-6274. PubMed ID: 38039244 [TBL] [Abstract][Full Text] [Related]
11. Visible ghost imaging with nonvisible light. Duan D; Zhang L; Xia Y J Opt Soc Am A Opt Image Sci Vis; 2014 Apr; 31(4):730-3. PubMed ID: 24695134 [TBL] [Abstract][Full Text] [Related]
12. X-ray phase-contrast tomography with a compact laser-driven synchrotron source. Eggl E; Schleede S; Bech M; Achterhold K; Loewen R; Ruth RD; Pfeiffer F Proc Natl Acad Sci U S A; 2015 May; 112(18):5567-72. PubMed ID: 25902493 [TBL] [Abstract][Full Text] [Related]
13. Coherence in X-ray physics. Lengeler B Naturwissenschaften; 2001 Jun; 88(6):249-60. PubMed ID: 11544952 [TBL] [Abstract][Full Text] [Related]
16. MO-A-BRB-02: Facts and Fiction of Flattening Filter Free (FF-FFF) X-Rays Beams. Ting J Med Phys; 2012 Jun; 39(6Part20):3861-3862. PubMed ID: 28517518 [TBL] [Abstract][Full Text] [Related]
17. An inverse free electron laser acceleration-driven Compton scattering X-ray source. Gadjev I; Sudar N; Babzien M; Duris J; Hoang P; Fedurin M; Kusche K; Malone R; Musumeci P; Palmer M; Pogorelsky I; Polyanskiy M; Sakai Y; Swinson C; Williams O; Rosenzweig JB Sci Rep; 2019 Jan; 9(1):532. PubMed ID: 30679471 [TBL] [Abstract][Full Text] [Related]
18. Coherent diffractive imaging of biological samples at synchrotron and free electron laser facilities. Mancuso AP; Yefanov OM; Vartanyants IA J Biotechnol; 2010 Sep; 149(4):229-37. PubMed ID: 20149827 [TBL] [Abstract][Full Text] [Related]
19. Compensating the electron beam energy spread by the natural transverse gradient of laser undulator in all-optical x-ray light sources. Zhang T; Feng C; Deng H; Wang D; Dai Z; Zhao Z Opt Express; 2014 Jun; 22(11):13880-8. PubMed ID: 24921579 [TBL] [Abstract][Full Text] [Related]