These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
830 related articles for article (PubMed ID: 30003366)
41. Transcatheter aortic valve implantation with a Sapien 3 Commander 20 mm valves in patients with degenerated 19 mm bioprosthetic aortic valve. Loyalka P; Nascimbene A; Schechter M; Petrovic M; Sundara Raman A; Gregoric ID; Kar B Catheter Cardiovasc Interv; 2017 Jun; 89(7):1280-1285. PubMed ID: 27696659 [TBL] [Abstract][Full Text] [Related]
43. Transcatheter Aortic Valve Replacement of Failed Surgically Implanted Bioprostheses: The STS/ACC Registry. Tuzcu EM; Kapadia SR; Vemulapalli S; Carroll JD; Holmes DR; Mack MJ; Thourani VH; Grover FL; Brennan JM; Suri RM; Dai D; Svensson LG J Am Coll Cardiol; 2018 Jul; 72(4):370-382. PubMed ID: 30025572 [TBL] [Abstract][Full Text] [Related]
44. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. Athappan G; Patvardhan E; Tuzcu EM; Svensson LG; Lemos PA; Fraccaro C; Tarantini G; Sinning JM; Nickenig G; Capodanno D; Tamburino C; Latib A; Colombo A; Kapadia SR J Am Coll Cardiol; 2013 Apr; 61(15):1585-95. PubMed ID: 23500308 [TBL] [Abstract][Full Text] [Related]
45. Complications after Transfemoral Transcatheter Aortic Valve Replacement with a Balloon-Expandable Prosthesis: The Importance of Preventative Measures and Contingency Planning. Chakravarty T; Jilaihawi H; Doctor N; Fontana G; Forrester JS; Cheng W; Makkar R Catheter Cardiovasc Interv; 2018 Apr; 91(5):E29-E42. PubMed ID: 23436313 [TBL] [Abstract][Full Text] [Related]
46. Transaortic transcatheter aortic valve implantation using SAPIEN XT or SAPIEN 3 valves in the ROUTE registry. Romano M; Frank D; Cocchieri R; Jagielak D; Bonaros N; Aiello M; Lapeze J; Laine M; Chocron S; Muir D; Eichinger W; Thielmann M; Labrousse L; Arne Rein K; Verhoye JP; Gerosa G; Baumbach H; Deutsch C; Bramlage P; Thoenes M; Bapat V Interact Cardiovasc Thorac Surg; 2017 Nov; 25(5):757-764. PubMed ID: 28582580 [TBL] [Abstract][Full Text] [Related]
47. Association of Paravalvular Regurgitation With 1-Year Outcomes After Transcatheter Aortic Valve Replacement With the SAPIEN 3 Valve. Pibarot P; Hahn RT; Weissman NJ; Arsenault M; Beaudoin J; Bernier M; Dahou A; Khalique OK; Asch FM; Toubal O; Leipsic J; Blanke P; Zhang F; Parvataneni R; Alu M; Herrmann H; Makkar R; Mack M; Smalling R; Leon M; Thourani VH; Kodali S JAMA Cardiol; 2017 Nov; 2(11):1208-1216. PubMed ID: 28973091 [TBL] [Abstract][Full Text] [Related]
49. A Randomized Evaluation of the SAPIEN XT Transcatheter Heart Valve System in Patients With Aortic Stenosis Who Are Not Candidates for Surgery. Webb JG; Doshi D; Mack MJ; Makkar R; Smith CR; Pichard AD; Kodali S; Kapadia S; Miller DC; Babaliaros V; Thourani V; Herrmann HC; Bodenhamer M; Whisenant BK; Ramee S; Maniar H; Kereiakes D; Xu K; Jaber WA; Menon V; Tuzcu EM; Wood D; Svensson LG; Leon MB JACC Cardiovasc Interv; 2015 Dec; 8(14):1797-806. PubMed ID: 26718510 [TBL] [Abstract][Full Text] [Related]
50. Outcomes After Transcatheter Aortic Valve Replacement Using a Novel Balloon-Expandable Transcatheter Heart Valve: A Single-Center Experience. Husser O; Pellegrini C; Kessler T; Burgdorf C; Thaller H; Mayr NP; Ott I; Kasel AM; Schunkert H; Kastrati A; Hengstenberg C JACC Cardiovasc Interv; 2015 Dec; 8(14):1809-16. PubMed ID: 26718512 [TBL] [Abstract][Full Text] [Related]
51. Challenging transfemoral valve-in-valve implantation in a degenerated stentless bioprosthetic aortic valve. Halapas A; Chrissoheris M; Spargias K J Invasive Cardiol; 2014 Aug; 26(8):E106-8. PubMed ID: 25091103 [TBL] [Abstract][Full Text] [Related]
52. Incidence of Long-Term Structural Valve Dysfunction and Bioprosthetic Valve Failure After Transcatheter Aortic Valve Replacement. Barbanti M; Costa G; Zappulla P; Todaro D; Picci A; Rapisarda G; Di Simone E; Sicuso R; Buccheri S; Gulino S; Pilato G; La Spina K; D'Arrigo P; Valvo R; Indelicato A; Giannazzo D; Immè S; Tamburino C; Patanè M; Sgroi C; Giuffrida A; Trovato D; Monte IP; Deste W; Capranzano P; Capodanno D; Tamburino C J Am Heart Assoc; 2018 Aug; 7(15):e008440. PubMed ID: 30371244 [TBL] [Abstract][Full Text] [Related]
53. Incidence, Predictors, and Clinical Impact of Prosthesis-Patient Mismatch Following Transcatheter Aortic Valve Replacement in Asian Patients: The OCEAN-TAVI Registry. Miyasaka M; Tada N; Taguri M; Kato S; Enta Y; Otomo T; Hata M; Watanabe Y; Naganuma T; Araki M; Yamanaka F; Shirai S; Ueno H; Mizutani K; Tabata M; Higashimori A; Takagi K; Yamamoto M; Hayashida K; JACC Cardiovasc Interv; 2018 Apr; 11(8):771-780. PubMed ID: 29673509 [TBL] [Abstract][Full Text] [Related]
58. Two-Year Outcomes in Patients With Severe Aortic Valve Stenosis Randomized to Transcatheter Versus Surgical Aortic Valve Replacement: The All-Comers Nordic Aortic Valve Intervention Randomized Clinical Trial. Søndergaard L; Steinbrüchel DA; Ihlemann N; Nissen H; Kjeldsen BJ; Petursson P; Ngo AT; Olsen NT; Chang Y; Franzen OW; Engstrøm T; Clemmensen P; Olsen PS; Thyregod HG Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27296202 [TBL] [Abstract][Full Text] [Related]
59. Alternative access for transcatheter aortic valve replacement in older adults: A collaborative study from France and United States. Damluji AA; Murman M; Byun S; Moscucci M; Resar JR; Hasan RK; Alfonso CE; Carrillo RG; Williams DB; Kwon CC; Cho PW; Dijos M; Peltan J; Heldman AW; Cohen MG; Leroux L Catheter Cardiovasc Interv; 2018 Nov; 92(6):1182-1193. PubMed ID: 29968273 [TBL] [Abstract][Full Text] [Related]