These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 30006576)

  • 1. Sub-nanoliter, real-time flow monitoring in microfluidic chips using a portable device and smartphone.
    Temiz Y; Delamarche E
    Sci Rep; 2018 Jul; 8(1):10603. PubMed ID: 30006576
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Digital microfluidic meter-on-chip.
    Fang Z; Ding Y; Zhang Z; Wang F; Wang Z; Wang H; Pan T
    Lab Chip; 2020 Feb; 20(4):722-733. PubMed ID: 31853525
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Capacitive platform for real-time wireless monitoring of liquid wicking in a paper strip.
    Ruiz-García I; Escobedo P; Ramos-Lorente CE; Erenas MM; Capitán-Vallvey LF; Carvajal MA; Palma AJ; López-Ruiz N
    Lab Chip; 2023 Sep; 23(18):4092-4103. PubMed ID: 37615614
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Programmable hydraulic resistor for microfluidic chips using electrogate arrays.
    Salva ML; Temiz Y; Rocca M; Arango YC; Niemeyer CM; Delamarche E
    Sci Rep; 2019 Nov; 9(1):17242. PubMed ID: 31754240
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Design and Fabrication of Capillary-Driven Flow Device for Point-Of-Care Diagnostics.
    Hassan SU; Zhang X
    Biosensors (Basel); 2020 Apr; 10(4):. PubMed ID: 32326641
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Capillary-driven multiparametric microfluidic chips for one-step immunoassays.
    Gervais L; Hitzbleck M; Delamarche E
    Biosens Bioelectron; 2011 Sep; 27(1):64-70. PubMed ID: 21752632
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Capillary-Driven Flow Microfluidics Combined with Smartphone Detection: An Emerging Tool for Point-of-Care Diagnostics.
    Hassan SU; Tariq A; Noreen Z; Donia A; Zaidi SZJ; Bokhari H; Zhang X
    Diagnostics (Basel); 2020 Jul; 10(8):. PubMed ID: 32708045
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Digital monitoring of the microchannel filling flow dynamics using a non-contactless smartphone-based nano-liter precision flow velocity meter.
    Xu W; Atik AY; Beker L; Ceylan Koydemir H
    Biosens Bioelectron; 2024 May; 252():116130. PubMed ID: 38417285
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A low-cost smartphone controlled portable system with accurately confined on-chip 3D electrodes for flow-through cell electroporation.
    Han C; He X; Wang J; Gao L; Yang G; Li D; Wang S; Chen X; Peng Z
    Bioelectrochemistry; 2020 Aug; 134():107486. PubMed ID: 32179452
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Photothermally generated bubble on fiber (BoF) for precise sensing and control of liquid flow along a microfluidic channel.
    Ma J; Wang G; Jin L; Oh K; Guan BO
    Opt Express; 2019 Jul; 27(14):19768-19777. PubMed ID: 31503732
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Development of a Portable Residual Chlorine Detection Device with a Combination of Microfluidic Chips and LS-BP Algorithm to Achieve Accurate Detection of Residual Chlorine in Water.
    Wang T; Niu J; Pang H; Meng X; Sun R; Xie J
    Micromachines (Basel); 2024 Aug; 15(8):. PubMed ID: 39203696
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Power-free, digital and programmable dispensing of picoliter droplets using a Digit Chip.
    Mepham A; Besant JD; Weinstein AW; Burgess IB; Sargent EH; Kelley SO
    Lab Chip; 2017 Apr; 17(8):1505-1514. PubMed ID: 28350406
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Coil spring-powered pump with inertial microfluidic chip for size-based isolation and enrichment of biological cells.
    Gwak H; Ha SM; Song JW; Hyun KA; Jung HI
    Analyst; 2022 Dec; 147(24):5710-5717. PubMed ID: 36367196
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A smart and portable micropump for stable liquid delivery.
    Zhang X; Xia K; Ji A; Xiang N
    Electrophoresis; 2019 Mar; 40(6):865-872. PubMed ID: 30628114
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Microfluidics Integrated Biosensors: A Leading Technology towards Lab-on-a-Chip and Sensing Applications.
    Luka G; Ahmadi A; Najjaran H; Alocilja E; DeRosa M; Wolthers K; Malki A; Aziz H; Althani A; Hoorfar M
    Sensors (Basel); 2015 Dec; 15(12):30011-31. PubMed ID: 26633409
    [TBL] [Abstract][Full Text] [Related]  

  • 16. MIP-on-a-chip: Artificial receptors on microfluidic platforms for biomedical applications.
    Karasu T; Özgür E; Uzun L
    J Pharm Biomed Anal; 2023 Mar; 226():115257. PubMed ID: 36669397
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new polymer lab-on-a-chip (LOC) based on a microfluidic capillary flow assay (MCFA) for detecting unbound cortisol in saliva.
    T U V; Ghosh S; Milleman A; Nguyen T; Ahn CH
    Lab Chip; 2020 Jun; 20(11):1961-1974. PubMed ID: 32347263
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A microfluidic paper-based analytical device (μPAD) with smartphone readout for chlorpyrifos-oxon screening in human serum.
    Tsagkaris AS; Migliorelli D; Uttl L; Filippini D; Pulkrabova J; Hajslova J
    Talanta; 2021 Jan; 222():121535. PubMed ID: 33167243
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optofluidic bioimaging platform for quantitative phase imaging of lab on a chip devices using digital holographic microscopy.
    Pandiyan VP; John R
    Appl Opt; 2016 Jan; 55(3):A54-9. PubMed ID: 26835958
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Nanoliter Centrifugal Liquid Dispenser Coupled with Superhydrophobic Microwell Array Chips for High-Throughput Cell Assays.
    Wang Y; Wu Y; Chen Y; Zhang J; Chen X; Liu P
    Micromachines (Basel); 2018 Jun; 9(6):. PubMed ID: 30424219
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.