These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
118 related articles for article (PubMed ID: 30010599)
1. A 12.8 k Current-Mode Velocity-Saturation ISFET Array for On-Chip Real-Time DNA Detection. Miscourides N; Yu LS; Rodriguez-Manzano J; Georgiou P IEEE Trans Biomed Circuits Syst; 2018 Oct; 12(5):1202-1214. PubMed ID: 30010599 [TBL] [Abstract][Full Text] [Related]
2. A Scalable ISFET Sensing and Memory Array With Sensor Auto-Calibration for On-Chip Real-Time DNA Detection. Moser N; Rodriguez-Manzano J; Lande TS; Georgiou P IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):390-401. PubMed ID: 29570065 [TBL] [Abstract][Full Text] [Related]
3. A Dual-Sensing Thermo-Chemical ISFET Array for DNA-Based Diagnostics. Cacho-Soblechero M; Malpartida-Cardenas K; Cicatiello C; Rodriguez-Manzano J; Georgiou P IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):477-489. PubMed ID: 32149696 [TBL] [Abstract][Full Text] [Related]
4. A High Offset Distribution Tolerance High Resolution ISFET Array With Auto-Compensation for Long-Term Bacterial Metabolism Monitoring. Duan M; Zhong X; Xu J; Lee YK; Bermak A IEEE Trans Biomed Circuits Syst; 2020 Jun; 14(3):463-476. PubMed ID: 32149695 [TBL] [Abstract][Full Text] [Related]
5. A low power sub- μW chemical gilbert cell for ISFET differential reaction monitoring. Kalofonou M; Toumazou C IEEE Trans Biomed Circuits Syst; 2014 Aug; 8(4):565-74. PubMed ID: 24240008 [TBL] [Abstract][Full Text] [Related]
6. An Optical and Temperature Assisted CMOS ISFET Sensor Array for Robust E. Coli Detection. Duan M; Zhong X; Zhao X; El-Agnaf OM; Lee YK; Bermak A IEEE Trans Biomed Circuits Syst; 2021 Jun; 15(3):497-508. PubMed ID: 34043514 [TBL] [Abstract][Full Text] [Related]
7. An Ultra-High Frame Rate Ion Imaging Platform Using ISFET Arrays With Real-Time Compression. Zeng J; Kuang L; Cacho-Soblechero M; Georgiou P IEEE Trans Biomed Circuits Syst; 2021 Aug; 15(4):820-833. PubMed ID: 34406947 [TBL] [Abstract][Full Text] [Related]
8. A 128 × 128 Current-Mode Ultra-High Frame Rate ISFET Array With In-Pixel Calibration for Real-Time Ion Imaging. Zeng J; Kuang L; Miscourides N; Georgiou P IEEE Trans Biomed Circuits Syst; 2020 Apr; 14(2):359-372. PubMed ID: 32070997 [TBL] [Abstract][Full Text] [Related]
9. A High-Sensitivity Potentiometric 65-nm CMOS ISFET Sensor for Rapid E. coli Screening. Jiang Y; Liu X; Dang TC; Huang X; Feng H; Zhang Q; Yu H IEEE Trans Biomed Circuits Syst; 2018 Apr; 12(2):402-415. PubMed ID: 29570066 [TBL] [Abstract][Full Text] [Related]
10. Label-free CMOS bio sensor with on-chip noise reduction scheme for real-time quantitative monitoring of biomolecules. Seong-Jin Kim ; Euisik Yoon IEEE Trans Biomed Circuits Syst; 2012 Jun; 6(3):189-96. PubMed ID: 23853141 [TBL] [Abstract][Full Text] [Related]
11. A Dual-Mode Large-Arrayed CMOS ISFET Sensor for Accurate and High-Throughput pH Sensing in Biomedical Diagnosis. Huang X; Yu H; Liu X; Jiang Y; Yan M; Wu D IEEE Trans Biomed Eng; 2015 Sep; 62(9):2224-33. PubMed ID: 25850082 [TBL] [Abstract][Full Text] [Related]
13. Electrical detection of nucleic acid amplification using an on-chip quasi-reference electrode and a PVC REFET. Salm E; Zhong Y; Reddy B; Duarte-Guevara C; Swaminathan V; Liu YS; Bashir R Anal Chem; 2014 Jul; 86(14):6968-75. PubMed ID: 24940939 [TBL] [Abstract][Full Text] [Related]
14. A robust ISFET pH-measuring front-end for chemical reaction monitoring. Hu Y; Georgiou P IEEE Trans Biomed Circuits Syst; 2014 Apr; 8(2):177-85. PubMed ID: 24808415 [TBL] [Abstract][Full Text] [Related]
15. Simultaneous DNA amplification and detection using a pH-sensing semiconductor system. Toumazou C; Shepherd LM; Reed SC; Chen GI; Patel A; Garner DM; Wang CJ; Ou CP; Amin-Desai K; Athanasiou P; Bai H; Brizido IM; Caldwell B; Coomber-Alford D; Georgiou P; Jordan KS; Joyce JC; La Mura M; Morley D; Sathyavruthan S; Temelso S; Thomas RE; Zhang L Nat Methods; 2013 Jul; 10(7):641-6. PubMed ID: 23749303 [TBL] [Abstract][Full Text] [Related]
16. Continuous Monitoring of pH and Blood Gases Using Ion-Sensitive and Gas-Sensitive Field Effect Transistors Operating in the Amperometric Mode in Presence of Drift. Jamasb S Biosensors (Basel); 2019 Mar; 9(1):. PubMed ID: 30889834 [TBL] [Abstract][Full Text] [Related]
17. Label-free DNA sensors using ultrasensitive diamond field-effect transistors in solution. Song KS; Zhang GJ; Nakamura Y; Furukawa K; Hiraki T; Yang JH; Funatsu T; Ohdomari I; Kawarada H Phys Rev E Stat Nonlin Soft Matter Phys; 2006 Oct; 74(4 Pt 1):041919. PubMed ID: 17155108 [TBL] [Abstract][Full Text] [Related]
18. [Establishment of loop-mediated isothermal amplification technique for rapid detection of NDM-1 gene]. Zhang Y; Wu N; Zhu B; Chen L; Zhu Y Sheng Wu Gong Cheng Xue Bao; 2011 Aug; 27(8):1232-8. PubMed ID: 22097813 [TBL] [Abstract][Full Text] [Related]
19. Loop-mediated isothermal amplification assay targeting the blaCTX-M9 gene for detection of extended spectrum β-lactamase-producing Escherichia coli and Klebsiella pneumoniae. Thirapanmethee K; Pothisamutyothin K; Nathisuwan S; Chomnawang MT; Wiwat C Microbiol Immunol; 2014 Dec; 58(12):655-65. PubMed ID: 25284314 [TBL] [Abstract][Full Text] [Related]
20. Ultrafast Large-Scale Chemical Sensing With CMOS ISFETs: A Level-Crossing Time-Domain Approach. Liu Y; Constandinou TG; Georgiou P IEEE Trans Biomed Circuits Syst; 2019 Dec; 13(6):1201-1213. PubMed ID: 31613781 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]