These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
197 related articles for article (PubMed ID: 30015586)
1. High-Frame-Rate Contrast-enhanced US Particle Image Velocimetry in the Abdominal Aorta: First Human Results. Engelhard S; Voorneveld J; Vos HJ; Westenberg JJM; Gijsen FJH; Taimr P; Versluis M; de Jong N; Bosch JG; Reijnen MMPJ; Groot Jebbink E Radiology; 2018 Oct; 289(1):119-125. PubMed ID: 30015586 [TBL] [Abstract][Full Text] [Related]
2. Echo Particle Image Velocimetry for Estimation of Carotid Artery Wall Shear Stress: Repeatability, Reproducibility and Comparison with Phase-Contrast Magnetic Resonance Imaging. Gurung A; Gates PE; Mazzaro L; Fulford J; Zhang F; Barker AJ; Hertzberg J; Aizawa K; Strain WD; Elyas S; Shore AC; Shandas R Ultrasound Med Biol; 2017 Aug; 43(8):1618-1627. PubMed ID: 28501327 [TBL] [Abstract][Full Text] [Related]
3. US Velocimetry in Participants with Aortoiliac Occlusive Disease. Engelhard S; van Helvert M; Voorneveld J; Bosch JG; Lajoinie GPR; Versluis M; Groot Jebbink E; Reijnen MMPJ Radiology; 2021 Nov; 301(2):332-338. PubMed ID: 34427462 [TBL] [Abstract][Full Text] [Related]
4. In vitro and preliminary in vivo validation of echo particle image velocimetry in carotid vascular imaging. Zhang F; Lanning C; Mazzaro L; Barker AJ; Gates PE; Strain WD; Fulford J; Gosling OE; Shore AC; Bellenger NG; Rech B; Chen J; Chen J; Shandas R Ultrasound Med Biol; 2011 Mar; 37(3):450-64. PubMed ID: 21316562 [TBL] [Abstract][Full Text] [Related]
5. High-Frame-Rate Contrast-Enhanced Ultrasound for Velocimetry in the Human Abdominal Aorta. Voorneveld J; Engelhard S; Vos HJ; Reijnen MMPJ; Gijsen F; Versluis M; Jebbink EG; de Jong N; Bosch JG IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Dec; 65(12):2245-2254. PubMed ID: 29994206 [TBL] [Abstract][Full Text] [Related]
6. Echo particle image velocimetry. DeMarchi N; White C J Vis Exp; 2012 Dec; (70):. PubMed ID: 23299186 [TBL] [Abstract][Full Text] [Related]
7. High-Frame-Rate Ultrasound Velocimetry in the Healthy Femoral Bifurcation: A Comparative Study Against 4-D Flow Magnetic Resonance Imaging. van Helvert M; Ruisch J; de Bakker JMK; Saris AECM; de Korte CL; Versluis M; Groot Jebbink E; Reijnen MMPJ Ultrasound Med Biol; 2024 Dec; 50(12):1755-1763. PubMed ID: 39244482 [TBL] [Abstract][Full Text] [Related]
8. Echocardiographic particle image velocimetry: a novel technique for quantification of left ventricular blood vorticity pattern. Kheradvar A; Houle H; Pedrizzetti G; Tonti G; Belcik T; Ashraf M; Lindner JR; Gharib M; Sahn D J Am Soc Echocardiogr; 2010 Jan; 23(1):86-94. PubMed ID: 19836203 [TBL] [Abstract][Full Text] [Related]
9. Measurement of Wall Shear Stress Exerted by Flowing Blood in the Human Carotid Artery: Ultrasound Doppler Velocimetry and Echo Particle Image Velocimetry. Gates PE; Gurung A; Mazzaro L; Aizawa K; Elyas S; Strain WD; Shore AC; Shandas R Ultrasound Med Biol; 2018 Jul; 44(7):1392-1401. PubMed ID: 29678322 [TBL] [Abstract][Full Text] [Related]
10. Micro-ultrasound biofluid imaging and multi-component velocity measurement with micro echo particle image velocimetry technique. Qian M; Yan L; Niu L; Jin Q; Ling T; Chen Y; Zheng H Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():451-4. PubMed ID: 19964936 [TBL] [Abstract][Full Text] [Related]
11. Advantages in using multi-frequency driving ultrasound for optimizing echo particle image velocimetry techniques. Zheng H; Mukdadi O; Hertzberg J; Shandas R Biomed Sci Instrum; 2004; 40():371-6. PubMed ID: 15133986 [TBL] [Abstract][Full Text] [Related]
12. Numerical modeling of microbubble backscatter to optimize ultrasound particle image velocimetry imaging: initial studies. Mukdadi OM; Kim HB; Hertzberg J; Shandas R Ultrasonics; 2004 Aug; 42(10):1111-21. PubMed ID: 15234173 [TBL] [Abstract][Full Text] [Related]
13. Advantages in using multifrequency excitation of contrast microbubbles for enhancing echo particle image velocimetry techniques: initial numerical studies using rectangular and triangular waves. Zheng H; Mukdadi O; Kim H; Hertzberg JR; Shandas R Ultrasound Med Biol; 2005 Jan; 31(1):99-108. PubMed ID: 15653236 [TBL] [Abstract][Full Text] [Related]
14. 4-D Echo-Particle Image Velocimetry in a Left Ventricular Phantom. Voorneveld J; Saaid H; Schinkel C; Radeljic N; Lippe B; Gijsen FJH; van der Steen AFW; de Jong N; Claessens T; Vos HJ; Kenjeres S; Bosch JG Ultrasound Med Biol; 2020 Mar; 46(3):805-817. PubMed ID: 31924419 [TBL] [Abstract][Full Text] [Related]
15. Development of a custom-designed echo particle image velocimetry system for multi-component hemodynamic measurements: system characterization and initial experimental results. Liu L; Zheng H; Williams L; Zhang F; Wang R; Hertzberg J; Shandas R Phys Med Biol; 2008 Mar; 53(5):1397-412. PubMed ID: 18296769 [TBL] [Abstract][Full Text] [Related]
16. 4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography. Gabbour M; Schnell S; Jarvis K; Robinson JD; Markl M; Rigsby CK Pediatr Radiol; 2015 Jun; 45(6):804-13. PubMed ID: 25487721 [TBL] [Abstract][Full Text] [Related]
17. Sub-piexl methods for improving vector quality in echo PIV flow, imaging technology. Niu L; Wang J; Qian M; Zheng H Annu Int Conf IEEE Eng Med Biol Soc; 2009; 2009():487-90. PubMed ID: 19963463 [TBL] [Abstract][Full Text] [Related]
18. Ultrasonic particle image velocimetry for improved flow gradient imaging: algorithms, methodology and validation. Niu L; Qian M; Wan K; Yu W; Jin Q; Ling T; Gao S; Zheng H Phys Med Biol; 2010 Apr; 55(7):2103-20. PubMed ID: 20299721 [TBL] [Abstract][Full Text] [Related]
19. Mapping mean and fluctuating velocities by Bayesian multipoint MR velocity encoding-validation against 3D particle tracking velocimetry. Knobloch V; Binter C; Gülan U; Sigfridsson A; Holzner M; Lüthi B; Kozerke S Magn Reson Med; 2014 Apr; 71(4):1405-15. PubMed ID: 23670993 [TBL] [Abstract][Full Text] [Related]
20. Left ventricular high frame rate echo-particle image velocimetry: clinical application and comparison with conventional imaging. Strachinaru M; Voorneveld J; Keijzer LBH; Bowen DJ; Mutluer FO; Cate FT; de Jong N; Vos HJ; Bosch JG; van den Bosch AE Cardiovasc Ultrasound; 2022 Apr; 20(1):11. PubMed ID: 35473581 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]