40 related articles for article (PubMed ID: 3001864)
1. [The effect of beam hardening on CT values].
Weidenmaier W; Christ G
Rofo; 1985 Dec; 143(6):697-701. PubMed ID: 3001864
[TBL] [Abstract][Full Text] [Related]
2. Beam hardening artefacts in computed tomography with photon counting, charge integrating and energy weighting detectors: a simulation study.
Shikhaliev PM
Phys Med Biol; 2005 Dec; 50(24):5813-27. PubMed ID: 16333157
[TBL] [Abstract][Full Text] [Related]
3. An inaccuracy in computed tomography: the energy dependence of CT values.
Zatz LM; Alvarez RE
Radiology; 1977 Jul; 124(1):91-7. PubMed ID: 866662
[TBL] [Abstract][Full Text] [Related]
4. [Effects of beam weakening and beam hardening on the measured CT values].
Schultz E; Lackner K
Computertomographie; 1981 Jun; 1(2):83-8. PubMed ID: 7187286
[TBL] [Abstract][Full Text] [Related]
5. Development of novel statistical reconstruction algorithms for poly-energetic X-ray computed tomography.
Chueh HS; Tsai WK; Chang CC; Chang SM; Su KH; Chen JC
Comput Methods Programs Biomed; 2008 Dec; 92(3):289-93. PubMed ID: 18508153
[TBL] [Abstract][Full Text] [Related]
6. Computed tomography with monochromatic x rays.
Dilmanian FA
Am J Physiol Imaging; 1992; 7(3-4):175-93. PubMed ID: 1343214
[TBL] [Abstract][Full Text] [Related]
7. The environmental density artifact: a beam-hardening effect in computed tomography.
Rao PS; Alfidi RJ
Radiology; 1981 Oct; 141(1):223-7. PubMed ID: 7291529
[TBL] [Abstract][Full Text] [Related]
8. Determination of the weighted CT dose index in modern multi-detector CT scanners.
Perisinakis K; Damilakis J; Tzedakis A; Papadakis A; Theocharopoulos N; Gourtsoyiannis N
Phys Med Biol; 2007 Nov; 52(21):6485-95. PubMed ID: 17951857
[TBL] [Abstract][Full Text] [Related]
9. Variations in measured computed tomography number values.
Faulkner K; Moores BM
Radiography; 1985; 51(597):163-7. PubMed ID: 4011863
[TBL] [Abstract][Full Text] [Related]
10. Dual-energy CT-based material extraction for tissue segmentation in Monte Carlo dose calculations.
Bazalova M; Carrier JF; Beaulieu L; Verhaegen F
Phys Med Biol; 2008 May; 53(9):2439-56. PubMed ID: 18421124
[TBL] [Abstract][Full Text] [Related]
11. X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.
Kinahan PE; Hasegawa BH; Beyer T
Semin Nucl Med; 2003 Jul; 33(3):166-79. PubMed ID: 12931319
[TBL] [Abstract][Full Text] [Related]
12. [Material selective imaging and density measurement with the dual energy method. III. Determination of bone mineral of the spine with CT].
Kalender W; Felsenberg D; Süss C
Digitale Bilddiagn; 1987 Dec; 7(4):170-6. PubMed ID: 3436119
[TBL] [Abstract][Full Text] [Related]
13. Use of X-ray tomography to map crystalline and amorphous phases in frozen biomaterials.
Bischof JC; Mahr B; Choi JH; Behling M; Mewes D
Ann Biomed Eng; 2007 Feb; 35(2):292-304. PubMed ID: 17136446
[TBL] [Abstract][Full Text] [Related]
14. Systematic analysis of biological and physical limitations of proton beam range verification with offline PET/CT scans.
Knopf A; Parodi K; Bortfeld T; Shih HA; Paganetti H
Phys Med Biol; 2009 Jul; 54(14):4477-95. PubMed ID: 19556685
[TBL] [Abstract][Full Text] [Related]
15. Reconstruction algorithm for polychromatic CT imaging: application to beam hardening correction.
Yan CH; Whalen RT; Beaupré GS; Yen SY; Napel S
IEEE Trans Med Imaging; 2000 Jan; 19(1):1-11. PubMed ID: 10782614
[TBL] [Abstract][Full Text] [Related]
16. Quantitative assessment of the physical potential of proton beam range verification with PET/CT.
Knopf A; Parodi K; Paganetti H; Cascio E; Bonab A; Bortfeld T
Phys Med Biol; 2008 Aug; 53(15):4137-51. PubMed ID: 18635897
[TBL] [Abstract][Full Text] [Related]
17. Quantitative analysis of CT brain images: a statistical model incorporating partial volume and beam hardening effects.
McLoughlin RF; Ryan MV; Heuston PM; McCoy CT; Masterson JB
Br J Radiol; 1992 May; 65(773):425-30. PubMed ID: 1611423
[TBL] [Abstract][Full Text] [Related]
18. [Beam hardening correction method for X-ray computed tomography based on subsection beam hardening curves].
Huang KD; Zhang DH
Guang Pu Xue Yu Guang Pu Fen Xi; 2009 Sep; 29(9):2581-4. PubMed ID: 19950681
[TBL] [Abstract][Full Text] [Related]
19. A beam-hardening correction using dual-energy computed tomography.
Coleman AJ; Sinclair M
Phys Med Biol; 1985 Nov; 30(11):1251-6. PubMed ID: 4080822
[No Abstract] [Full Text] [Related]
20. The apical artifact: elevated attenuation values toward the apex of the skull.
Di Chiro G; Brooks RA; Dubal L; Chew E
J Comput Assist Tomogr; 1978 Jan; 2(1):65-70. PubMed ID: 670474
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]