BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

148 related articles for article (PubMed ID: 30028488)

  • 1. Multislice computed tomographic measurements of optic nerve sheath diameter in brain injury patients.
    Özsaraç M; Düzgün F; Gölcük Y; Pabuşcu Y; Bilge A; İrik M; Yılmaz H
    Ulus Travma Acil Cerrahi Derg; 2018 Jul; 24(4):316-320. PubMed ID: 30028488
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Correlation of intracranial pressure and diameter of the sheath of the optic nerve by computed tomography in severe traumatic brain injury].
    Turkin AM; Oshorov AV; Pogosbekyan EL; Smirnov AS; Dmitrieva AS
    Zh Vopr Neirokhir Im N N Burdenko; 2017; 81(6):81-88. PubMed ID: 29393290
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Optic Nerve Sheath Measurements by Computed Tomography to Predict Intracranial Pressure and Guide Surgery in Patients with Traumatic Brain Injury.
    Liu M; Yang ZK; Yan YF; Shen X; Yao HB; Fei L; Wang ES
    World Neurosurg; 2020 Feb; 134():e317-e324. PubMed ID: 31629929
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Prognostic significance of optic nerve sheath diameter on computed tomography scan with severity of blunt traumatic brain injury in the emergency department.
    Waheed S; Baig MA; Siddiqui E; Jamil D; Bashar M; Feroze A
    J Pak Med Assoc; 2018 Feb; 68(2):268-271. PubMed ID: 29479105
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Intracranial Pressure Assessment in Traumatic Head Injury with Hemorrhage Via Optic Nerve Sheath Diameter.
    Vaiman M; Sigal T; Kimiagar I; Bekerman I
    J Neurotrauma; 2016 Dec; 33(23):2147-2153. PubMed ID: 27048793
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.
    Raffiz M; Abdullah JM
    Am J Emerg Med; 2017 Jan; 35(1):150-153. PubMed ID: 27852525
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Ratio of Optic Nerve Sheath Diameter to Eyeball Transverse Diameter by Ultrasound Can Predict Intracranial Hypertension in Traumatic Brain Injury Patients: A Prospective Study.
    Du J; Deng Y; Li H; Qiao S; Yu M; Xu Q; Wang C
    Neurocrit Care; 2020 Apr; 32(2):478-485. PubMed ID: 31218637
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ultrasonographic measured optic nerve sheath diameter as an accurate and quick monitor for changes in intracranial pressure.
    Maissan IM; Dirven PJ; Haitsma IK; Hoeks SE; Gommers D; Stolker RJ
    J Neurosurg; 2015 Sep; 123(3):743-7. PubMed ID: 25955869
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Is initial optic nerve sheath diameter prognostic of specific head injury in emergency departments?
    Sönmez BM; Temel E; İşcanlı MD; Yılmaz F; Gülöksüz U; Parlak S; Uçkun ÖM
    J Natl Med Assoc; 2019 Apr; 111(2):210-217. PubMed ID: 30415927
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optic nerve sheath diameter based on preoperative brain computed tomography and intracranial pressure are positively correlated in adults with hydrocephalus.
    Lee HC; Lee WJ; Dho YS; Cho WS; Kim YH; Park HP
    Clin Neurol Neurosurg; 2018 Apr; 167():31-35. PubMed ID: 29433056
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Correlation between optic nerve sheath diameter measured on imaging with acute pathologies found on computed tomography of trauma patients.
    Jenjitranant P; Tunlayadechanont P; Prachanukool T; Kaewlai R
    Eur J Radiol; 2020 Apr; 125():108875. PubMed ID: 32105916
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Assessment of intracranial pressure with ultrasonographic retrobulbar optic nerve sheath diameter measurement.
    Liu D; Li Z; Zhang X; Zhao L; Jia J; Sun F; Wang Y; Ma D; Wei W
    BMC Neurol; 2017 Sep; 17(1):188. PubMed ID: 28962603
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility of optic nerve sheath diameter measured on initial brain computed tomography as an early neurologic outcome predictor after cardiac arrest.
    Hwan Kim Y; Ho Lee J; Kun Hong C; Won Cho K; Hoon Yeo J; Ju Kang M; Weon Kim Y; Yul Lee K; Joo Kim J; Youn Hwang S
    Acad Emerg Med; 2014 Oct; 21(10):1121-8. PubMed ID: 25308135
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Optic nerve sheath diameter measurement for predicting raised intracranial pressure in adult patients with severe traumatic brain injury: A meta-analysis.
    Lee SH; Kim HS; Yun SJ
    J Crit Care; 2020 Apr; 56():182-187. PubMed ID: 31945584
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Use of the sonographic diameter of optic nerve sheath to estimate intracranial pressure.
    Amini A; Kariman H; Arhami Dolatabadi A; Hatamabadi HR; Derakhshanfar H; Mansouri B; Safari S; Eqtesadi R
    Am J Emerg Med; 2013 Jan; 31(1):236-9. PubMed ID: 22944553
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Diagnostic and prognostic value of the optic nerve sheath diameter with respect to the intracranial pressure and neurological outcome of patients following hemicraniectomy.
    Gao Y; Li Q; Wu C; Liu S; Zhang M
    BMC Neurol; 2018 Dec; 18(1):199. PubMed ID: 30518315
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The concordance of optic nerve sheath diameter measurements with the clinical course in children with traumatic head injury.
    Kavak RP; Özdemir M; Kavak N; Ertan N; Külah B
    Ulus Travma Acil Cerrahi Derg; 2020 Sep; 26(5):728-734. PubMed ID: 32946080
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved diagnostic value of a TCD-based non-invasive ICP measurement method compared with the sonographic ONSD method for detecting elevated intracranial pressure.
    Ragauskas A; Bartusis L; Piper I; Zakelis R; Matijosaitis V; Petrikonis K; Rastenyte D
    Neurol Res; 2014 Jul; 36(7):607-14. PubMed ID: 24620972
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optic nerve sheath diameter on facial CT: a tool to predict traumatic brain injury.
    Lee SH; Yun SJ
    Eur J Trauma Emerg Surg; 2020 Aug; 46(4):879-885. PubMed ID: 30324239
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Sonographic optic nerve sheath diameter as an estimate of intracranial pressure in adult trauma.
    Strumwasser A; Kwan RO; Yeung L; Miraflor E; Ereso A; Castro-Moure F; Patel A; Sadjadi J; Victorino GP
    J Surg Res; 2011 Oct; 170(2):265-71. PubMed ID: 21550065
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.