These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

190 related articles for article (PubMed ID: 30031779)

  • 1. Supra-annular Transcatheter Aortic Valve-in-valve Implantation for a Degenerative Bioprosthesis.
    Pascual-Tejerina V; Moreno R; Galeote G
    Rev Esp Cardiol (Engl Ed); 2019 Aug; 72(8):672. PubMed ID: 30031779
    [No Abstract]   [Full Text] [Related]  

  • 2. Concomitant transfemoral transcatheter aortic and mitral valve-in-valve replacement.
    Rene AG; Desai N; Anwaruddin S
    J Card Surg; 2017 Aug; 32(8):479-482. PubMed ID: 28833637
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transcatheter valve-in-valve implantation for early prosthetic valve degeneration in aortic and mitral positions.
    Yamane K; Nazif TM; Khalique O; Hahn RT; Leon MB; Kodali SK; Williams MR; George I
    Ann Thorac Surg; 2014 Jul; 98(1):318-21. PubMed ID: 24996712
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The risk of oversizing with sutureless bioprosthesis in small aortic annulus.
    Baert J; Astarci P; Noirhomme P; de Kerchove L
    J Thorac Cardiovasc Surg; 2017 Feb; 153(2):270-272. PubMed ID: 27756462
    [No Abstract]   [Full Text] [Related]  

  • 5. A Technique for Avoiding Patient-Prosthesis Mismatch in the Small Aortic Root.
    Alameddine AK; Alimov VK; Pluchino F
    J Card Surg; 2016 May; 31(5):309-10. PubMed ID: 27018394
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transcatheter Aortic Valve Replacement for Perceval Sutureless Aortic Valve Failure.
    Kalra A; Reyes M; Yang EY; Little SH; Nabi F; Barker CM; Ramchandani M; Reul RM; Reardon MJ; Kleiman NS
    J Invasive Cardiol; 2017 Jun; 29(6):E65-E66. PubMed ID: 28570238
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Valve-in-valve transcatheter aortic valve implantation for bioprosthetic aortic sutureless valve failure: a case series.
    Vilalta V; Carrillo X; Fernández-Nofrerías E; González-Lopera M; Mauri J; Bayés-Genís A
    Rev Esp Cardiol (Engl Ed); 2021 Mar; 74(3):269-272. PubMed ID: 32807710
    [No Abstract]   [Full Text] [Related]  

  • 8. Trifecta Bioprosthesis Sudden-Onset Three-Leaflet Detachment.
    Reyes G; Monguio E; Gomez-Marino M; Gomez-Tello V; Cortina J
    Ann Thorac Surg; 2021 Feb; 111(2):e127-e128. PubMed ID: 32619616
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transcatheter aortic and mitral valve implantation in bioprosthetic valves: When one correction is not enough.
    Akujuo AC; Dellis SL; Delago AJ; Bennett EV
    J Thorac Cardiovasc Surg; 2015 Aug; 150(2):e15-7. PubMed ID: 26076999
    [No Abstract]   [Full Text] [Related]  

  • 10. Treatment of a failing St. Jude Medical Trifecta by Medtronic Corevalve Evolut valve-in-valve implantation.
    Haussig S; Schuler G; Linke A
    JACC Cardiovasc Interv; 2014 Jul; 7(7):e81-2. PubMed ID: 24954575
    [No Abstract]   [Full Text] [Related]  

  • 11. Early transcatheter aortic valve degeneration in the young.
    van Steenberghe M; de Vasconcelos CY; Delay D; Niclauss L; Kirsch M
    Int J Cardiol; 2016 Nov; 222():786-787. PubMed ID: 27522376
    [No Abstract]   [Full Text] [Related]  

  • 12. Two aortic valves.
    Dobrilovic N; Cohen L; Elefteriades JA
    Ann Thorac Surg; 2013 Jun; 95(6):2182. PubMed ID: 23706448
    [No Abstract]   [Full Text] [Related]  

  • 13. Transcatheter aortic valve-in-valve implantation for early failure of sutureless aortic bioprosthesis.
    Sun X; Song Z; Soffer D; Pirris JP
    J Card Surg; 2018 Apr; 33(4):172-175. PubMed ID: 29611217
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Valve-in-valve treatment of a degenerated supra-annular stentless bioprosthesis using a balloon-expandable transcatheter valve in a patient at high risk for coronary occlusion].
    Mauri S; Ferlini M; Aiello ML; Lanzarini LF; Raviola E; Gazzoli F; Maurelli M; Ferrario M
    G Ital Cardiol (Rome); 2017 Oct; 18(10):734-737. PubMed ID: 29105688
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Perceval Valve Implantation: Technical Details and Echocardiographic Assessment.
    Vasanthan V; Kent W; Gregory A; Maitland A; Cutrara C; Bouchard D; Asch F; Adams C
    Ann Thorac Surg; 2019 Mar; 107(3):e223-e225. PubMed ID: 30367839
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Concomitant transapical treatment of aortic stenosis and degenerated mitral bioprosthesis with two 29 mm Edwards Sapien XT prostheses.
    Misuraca L; Farah B; Tchetche D
    J Invasive Cardiol; 2013 Dec; 25(12):680-2. PubMed ID: 24296390
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Percutaneous Treatment of Early Denegeration of a Sutureless Bioprosthesis.
    García-Lara J; García-Puente J; Mateo-Martínez A; Pinar-Bermúdez E; Gutiérrez-García F; Valdés-Chávarri M
    Rev Esp Cardiol (Engl Ed); 2018 May; 71(5):398-399. PubMed ID: 28629948
    [No Abstract]   [Full Text] [Related]  

  • 18. Valve-in-valve transcatheter aortic valve implantation overcoming hostile anatomy: Evolut R for the treatment of Mitroflow bioprosthesis dysfunction.
    Ruparelia N; Colombo A; Latib A
    Cardiovasc Interv Ther; 2016 Oct; 31(4):292-5. PubMed ID: 26371364
    [TBL] [Abstract][Full Text] [Related]  

  • 19. First-in-human valve-in-valve implantation of a 20 mm balloon expandable transcatheter heart valve.
    Binder RK; Wood D; Webb JG; Cheung A
    Catheter Cardiovasc Interv; 2013 Dec; 82(7):E929-31. PubMed ID: 22821872
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Successful treatment of failing biological prosthesis because of "Stent creep" with valve-in-valve transcatheter aortic valve implantation.
    Attia R; Papalexopoulou N; Hancock J; Young C; Thomas M; Bapat V
    Catheter Cardiovasc Interv; 2015 Aug; 86(2):E119-25. PubMed ID: 24550020
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.