213 related articles for article (PubMed ID: 30047204)
1. Production of patient-specific electron beam aperture cut-outs using a low-cost, multi-purpose 3D printer.
Michiels S; Mangelschots B; Roover R; Devroye C; Depuydt T
J Appl Clin Med Phys; 2018 Sep; 19(5):756-760. PubMed ID: 30047204
[TBL] [Abstract][Full Text] [Related]
2. A method for generating intensity-modulated radiation therapy fields for small animal irradiators utilizing 3D-printed compensator molds.
Yoon SW; Kodra J; Miles DA; Kirsch DG; Oldham M
Med Phys; 2020 Sep; 47(9):4363-4371. PubMed ID: 32281657
[TBL] [Abstract][Full Text] [Related]
3. Investigating the accuracy of microstereotactic-body-radiotherapy utilizing anatomically accurate 3D printed rodent-morphic dosimeters.
Bache ST; Juang T; Belley MD; Koontz BF; Adamovics J; Yoshizumi TT; Kirsch DG; Oldham M
Med Phys; 2015 Feb; 42(2):846-55. PubMed ID: 25652497
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of deformable image registration between external beam radiotherapy and HDR brachytherapy for cervical cancer with a 3D-printed deformable pelvis phantom.
Kadoya N; Miyasaka Y; Nakajima Y; Kuroda Y; Ito K; Chiba M; Sato K; Dobashi S; Yamamoto T; Takahashi N; Kubozono M; Takeda K; Jingu K
Med Phys; 2017 Apr; 44(4):1445-1455. PubMed ID: 28214368
[TBL] [Abstract][Full Text] [Related]
5. Preclinical dose verification using a 3D printed mouse phantom for radiobiology experiments.
Esplen N; Therriault-Proulx F; Beaulieu L; Bazalova-Carter M
Med Phys; 2019 Nov; 46(11):5294-5303. PubMed ID: 31461781
[TBL] [Abstract][Full Text] [Related]
6. Characterizing 3D printing in the fabrication of variable density phantoms for quality assurance of radiotherapy.
Madamesila J; McGeachy P; Villarreal Barajas JE; Khan R
Phys Med; 2016 Jan; 32(1):242-7. PubMed ID: 26508016
[TBL] [Abstract][Full Text] [Related]
7. Technical note: Commissioning of a low-cost system for directly 3D printed flexible bolus.
Baltz GC; Kirsner SM
J Appl Clin Med Phys; 2023 Dec; 24(12):e14206. PubMed ID: 37962024
[TBL] [Abstract][Full Text] [Related]
8. Technical note: A comparison of in-house 3D-printed and commercially available patient-specific skin collimators for use with electron beam therapy.
Herchko SM; Rutenberg MS; Beltran CJ; Yaddanapudi S
J Appl Clin Med Phys; 2024 May; 25(5):e14366. PubMed ID: 38669190
[TBL] [Abstract][Full Text] [Related]
9. Preparation and fabrication of a full-scale, sagittal-sliced, 3D-printed, patient-specific radiotherapy phantom.
Craft DF; Howell RM
J Appl Clin Med Phys; 2017 Sep; 18(5):285-292. PubMed ID: 28857407
[TBL] [Abstract][Full Text] [Related]
10. Technical Note: Manufacturing of a realistic mouse phantom for dosimetry of radiobiology experiments.
Esplen N; Alyaqoub E; Bazalova-Carter M
Med Phys; 2019 Feb; 46(2):1030-1036. PubMed ID: 30488962
[TBL] [Abstract][Full Text] [Related]
11. Clinical implementation of 3D printing in the construction of patient specific bolus for electron beam radiotherapy for non-melanoma skin cancer.
Canters RA; Lips IM; Wendling M; Kusters M; van Zeeland M; Gerritsen RM; Poortmans P; Verhoef CG
Radiother Oncol; 2016 Oct; 121(1):148-153. PubMed ID: 27475278
[TBL] [Abstract][Full Text] [Related]
12. A dosimetric comparison of copper and Cerrobend electron inserts.
Rusk BD; Carver RL; Gibbons JP; Hogstrom KR
J Appl Clin Med Phys; 2016 Sep; 17(5):245–261. PubMed ID: 27685126
[TBL] [Abstract][Full Text] [Related]
13. Use of 3D printers to create a patient-specific 3D bolus for external beam therapy.
Burleson S; Baker J; Hsia AT; Xu Z
J Appl Clin Med Phys; 2015 May; 16(3):5247. PubMed ID: 26103485
[TBL] [Abstract][Full Text] [Related]
14. A customized bolus produced using a 3-dimensional printer for radiotherapy.
Kim SW; Shin HJ; Kay CS; Son SH
PLoS One; 2014; 9(10):e110746. PubMed ID: 25337700
[TBL] [Abstract][Full Text] [Related]
15. Evaluations of patient-specific bolus fabricated by mold-and-cast method using computer numerical control machine tools†.
Yu GB; Kwon J; Chae S; Lee SY; Jung S
J Radiat Res; 2023 Nov; 64(6):973-981. PubMed ID: 37839093
[TBL] [Abstract][Full Text] [Related]
16. Development of an accurate EPID-based output measurement and dosimetric verification tool for electron beam therapy.
Ding A; Xing L; Han B
Med Phys; 2015 Jul; 42(7):4190-8. PubMed ID: 26133618
[TBL] [Abstract][Full Text] [Related]
17. Patient specific 3D printed phantom for IMRT quality assurance.
Ehler ED; Barney BM; Higgins PD; Dusenbery KE
Phys Med Biol; 2014 Oct; 59(19):5763-73. PubMed ID: 25207965
[TBL] [Abstract][Full Text] [Related]
18. The feasibility of producing patient-specific acrylic cranioplasty implants with a low-cost 3D printer.
Tan ET; Ling JM; Dinesh SK
J Neurosurg; 2016 May; 124(5):1531-7. PubMed ID: 26566203
[TBL] [Abstract][Full Text] [Related]
19. Three-dimensional printer-generated patient-specific phantom for artificial in vivo dosimetry in radiotherapy quality assurance.
Kamomae T; Shimizu H; Nakaya T; Okudaira K; Aoyama T; Oguchi H; Komori M; Kawamura M; Ohtakara K; Monzen H; Itoh Y; Naganawa S
Phys Med; 2017 Dec; 44():205-211. PubMed ID: 29102154
[TBL] [Abstract][Full Text] [Related]
20. 3D-printed applicators for high dose rate brachytherapy: Dosimetric assessment at different infill percentage.
Ricotti R; Vavassori A; Bazani A; Ciardo D; Pansini F; Spoto R; Sammarco V; Cattani F; Baroni G; Orecchia R; Jereczek-Fossa BA
Phys Med; 2016 Dec; 32(12):1698-1706. PubMed ID: 27592531
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]