These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
353 related articles for article (PubMed ID: 30049271)
41. Vancomycin-modified implant surface inhibits biofilm formation and supports bone-healing in an infected osteotomy model in sheep: a proof-of-concept study. Stewart S; Barr S; Engiles J; Hickok NJ; Shapiro IM; Richardson DW; Parvizi J; Schaer TP J Bone Joint Surg Am; 2012 Aug; 94(15):1406-15. PubMed ID: 22854994 [TBL] [Abstract][Full Text] [Related]
42. Manual polishing of 3D printed metals produced by laser powder bed fusion reduces biofilm formation. McGaffey M; Zur Linden A; Bachynski N; Oblak M; James F; Weese JS PLoS One; 2019; 14(2):e0212995. PubMed ID: 30811509 [TBL] [Abstract][Full Text] [Related]
43. Electric block current induced detachment from surgical stainless steel and decreased viability of Staphylococcus epidermidis. van der Borden AJ; van der Mei HC; Busscher HJ Biomaterials; 2005 Nov; 26(33):6731-5. PubMed ID: 15979141 [TBL] [Abstract][Full Text] [Related]
44. Biofilm Formation of Staphylococcus aureus on Various Surfaces and Their Resistance to Chlorine Sanitizer. Lee JS; Bae YM; Lee SY; Lee SY J Food Sci; 2015 Oct; 80(10):M2279-86. PubMed ID: 26417663 [TBL] [Abstract][Full Text] [Related]
45. In vivo study of stainless steel and Ti-13Nb-13Zr bone plates in a sheep model. Seligson D; Mehta S; Mishra AK; FitzGerald TJ; Castleman DW; James AH; Voor MJ; Been J; Nawab A Clin Orthop Relat Res; 1997 Oct; (343):213-23. PubMed ID: 9345227 [TBL] [Abstract][Full Text] [Related]
46. Conformal Coating of Orthopedic Plates with X-ray Scintillators and pH Indicators for X-ray Excited Luminescence Chemical Imaging through Tissue. Uzair U; Johnson C; Beladi-Behbahani S; Rajamanthrilage AC; Raval YS; Benza D; Ranasinghe M; Schober G; Tzeng TJ; Anker JN ACS Appl Mater Interfaces; 2020 Nov; 12(47):52343-52353. PubMed ID: 33181017 [TBL] [Abstract][Full Text] [Related]
47. Adhesion of Staphylococcus to orthopaedic metals, an in vivo study. Sheehan E; McKenna J; Mulhall KJ; Marks P; McCormack D J Orthop Res; 2004 Jan; 22(1):39-43. PubMed ID: 14656657 [TBL] [Abstract][Full Text] [Related]
48. Carbon-infiltrated carbon nanotubes inhibit the development of Staphylococcus aureus biofilms. Bowden LC; Evans JGW; Miller KM; Bowden AE; Jensen BD; Hope S; Berges BK Sci Rep; 2023 Nov; 13(1):19398. PubMed ID: 37938619 [TBL] [Abstract][Full Text] [Related]
49. Surface hydrophobicity, nutritional contents affect Staphylococcus aureus biofilms and temperature influences its survival in preformed biofilms. Pagedar A; Singh J; Batish VK J Basic Microbiol; 2010 Dec; 50 Suppl 1():S98-106. PubMed ID: 20586075 [TBL] [Abstract][Full Text] [Related]
50. Biomechanical Comparison of Volar Fixed-Angle Locking Plates for AO C3 Distal Radius Fractures: Titanium Versus Stainless Steel With Compression. Marshall T; Momaya A; Eberhardt A; Chaudhari N; Hunt TR J Hand Surg Am; 2015 Oct; 40(10):2032-8. PubMed ID: 26253601 [TBL] [Abstract][Full Text] [Related]
51. Biofilm formation of Staphylococcus aureus on various implants used for surgical treatment of destructive spondylodiscitis. Zacher AT; Mirza K; Thieme L; Nietzsche S; Senft C; Schwarz F Sci Rep; 2024 Aug; 14(1):19364. PubMed ID: 39169088 [TBL] [Abstract][Full Text] [Related]
52. Resistance of pathogenic bacteria on the surface of stainless steel depending on attachment form and efficacy of chemical sanitizers. Bae YM; Baek SY; Lee SY Int J Food Microbiol; 2012 Feb; 153(3):465-73. PubMed ID: 22225983 [TBL] [Abstract][Full Text] [Related]
57. Nanoparticle ultrasonication outperforms conventional irrigation solutions in eradicating Staphylococcus aureus biofilm from titanium surfaces: an in vitro study. Schaffler BC; Longwell M; Byers B; Kreft R; Ramot R; Ramot Y; Schwarzkopf R Eur J Orthop Surg Traumatol; 2024 Jul; 34(5):2729-2734. PubMed ID: 38761198 [TBL] [Abstract][Full Text] [Related]
58. Impact of implant metal type and vancomycin prophylaxis on postoperative spine infection: an in-vivo study. Gupta S; Maitra S; Farooqi AS; Gupta K; Wetpiriyakul P; Pereira M; Durbin-Johnson B; Gupta MC Spine Deform; 2023 Jul; 11(4):815-823. PubMed ID: 36920741 [TBL] [Abstract][Full Text] [Related]
59. Cathodic voltage-controlled electrical stimulation of titanium for prevention of methicillin-resistant Staphylococcus aureus and Acinetobacter baumannii biofilm infections. Canty M; Luke-Marshall N; Campagnari A; Ehrensberger M Acta Biomater; 2017 Jan; 48():451-460. PubMed ID: 27890730 [TBL] [Abstract][Full Text] [Related]
60. Influence of material and microtopography on the development of local infection in vivo: experimental investigation in rabbits. Moriarty TF; Debefve L; Boure L; Campoccia D; Schlegel U; Richards RG Int J Artif Organs; 2009 Sep; 32(9):663-70. PubMed ID: 19882548 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]